About this file

This is an architectural drawing (Sheet A-413) for the United States Military Academy at West Point, specifically for a building renovation project (Building 606). The document is an enlarged floor plan drawing showing detailed architectural layouts for the 5th floor, including men's and women's restrooms (rooms 508 and 505), a stair #2 penthouse level, and a wheelchair lift section. The drawing is part of Addendum #6 for a repair project, with the contract number W912DS19C0034 and project number 94078, issued by the US Army Corps of Engineers New York District on 2 September 2025. The drawing includes multiple scaled views (1/4" = 1'-0" and 3/8" = 1'-0") and contains numerous technical annotations and keyed notes describing specific architectural details, materials, and construction specifications.

View the file

Other files

File Type Posted
MSEC- Building 606 - Amendment 9 - RFIs - 5 Nov 25.pdf PDF
A-601_AM 9.pdf PDF
08 71 00_AM 9.pdf PDF
MP-101_AM 7.pdf PDF
E-611_AM 7.pdf PDF
08 71 00_AM 7.pdf PDF
MSEC- Building 606 - Amendment 7 - RFIs - 21 Oct 25.pdf PDF
I-130_AM 6.pdf PDF
I-100.1_AM 6.pdf PDF
AD-301_AM 6.pdf PDF
A-305_AM 6.pdf PDF
A-102_AM 6.pdf PDF
A-502_AM 6.pdf PDF
A-504_AM 6.pdf PDF
MP-107_AM 6.pdf PDF
MP-105_AM 6.pdf PDF
MP-101_AM 6.pdf PDF
MH-101_AM 6.pdf PDF
S-322_AM 6.pdf PDF
S-315_AM 6.pdf PDF
S-107_AM 6.pdf PDF
07 52 00_AM 6.pdf PDF
08 60 45_AM 6.pdf PDF
08 81 00_AM 6.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
A-551_AM 5.pdf PDF
MSEC- Building 606 - Amendment 5 - RFIs - 8 Oct 25 rev JF.pdf PDF
Appendix G_AM 5.pdf PDF
A-601_AM 4.pdf PDF
Solicitation Amendment W912DS25RA0020004 SF 30.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
A-319.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

UP

B10 B11

BA

BB

AHU RM

605604

7' - 5 3/4" 13' - 4 1/2"

/2

1/ 2"

1/

2"

A1

A-414

METAL PANEL ON

CMU BACKUP.

STAIR 2

ST2

5/

8" 5'

7/ 8"

T

1"

0'

1"

4'

3/

4"

1/ 4"

13 A

DN

LADDER TO

ROOF ABOVE.

A5

A-414

A7

A-414

7' - 8" 4' - 3 3/4" 2' - 5" 4' - 3 3/4" 9 1/4"

WALL MOUNTED RAIL

EXTENDED BEYOND

STRUCTURAL

BRACING.

DIAGONAL BRACING,

REFER TO STRUCT

DWGS.

DN

16 A

3'

8" 1T

3' - 11"

STAIR 2B

5' - 6" 1T = 1' - 0" 4' - 6 1/2"

UP

5'

7/

8"

1' - 4" 3' - 4" 4' - 0" 3' - 4" 8' - 10 1/4"

A1

A-554

A1

A-554

A1

A-418

SIM

SIM A-507

c8

A-507

E7

/2

A-304 A4

STAIR 2A

B6 B7

B8

B8 B9

B8.2 B9.3 B9.8

B10 B11

BABA

BBBB

CL2

WOMENS

STAIR 2

ST2

CORRIDOR

A1

A-414

15' - 6 1/2" 12' - 1" 12' - 5" 17' - 3" 12' - 7" 1' - 8"

506508

9 A

3 A

9 A

3 A

14 A

9 A

12 A

11 A 13 A

13 A

13 A 13 A

13 A

13 A 16 A

HC SHR

HC SHR

HC LIFT

5'

0"

1/

2"

5' - 7 1/2" 4' - 0"+212'-1 1/4"

+211'-2"

+208'-6"

COLLAB513

COLLAB

CORRIDOR

JAN

5 A

3' - 6" 10 1/4" 13' - 0 1/4" 6" 10' - 0" 6" 13' - 3 1/2" 7" 1' - 0"

A-458

C1

A1

RAMP 3

STAIR 11

504A 504B

8'

16 A

20 A

5 A

3 A

9 A

1 A

/8

1'

1/

8"

9 A

1 - 71 - 7

MOP

SINK

A-410

E1

A-410

E3

1/

4" 4'

3/ 4"

T

1"

0'

1"

5'

1/

2"

2" M

IN

E1

A-413

M

IN

1' - 0"

7 TREAD @ 11"= 6' - 5"

A-411

D8

A-411

A8

A-411

D6

A-411

A6

SIM

2 - 3

A5

A-414

B11.1

B11.1

HCTHCT

1 A 1 A

SHAFT SHAFT

NOTE:

SEE D7/A-557 FOR TYP

SHOWER DTLS & DIMS.

A7

A-414

NOTE:

SEE SHEET A-411 FOR TOILET ACCESSORY

AND MIRROR SCHEDULE, TYPICAL TOILET

ROOM NOTES AND TLT STALL LAYOUT. SEE

SHEET A-002 FOR ACCESSORY MOUNTING

HEIGHTS.

3 A

2 - 1A

1/ 2"

FLOOR INFILL, SEE

STRUCT DWGS.

20 C 16 C

2'

5"

PROVIDE 1" AIR SPACE

BETWEEN PTNS (TYP).

UP

DN

BL13

13 A

5'

1/

2"

T

1"

5'

/4

4' - 3 3/4" 2' - 5" 4' - 3 3/4"

STEPS (2R)

3 C

21 C

1 A

1' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 1' - 6"

5' - 0 3/8" 5' - 4 7/8" 7' - 0" 6' - 6 1/4" 5' - 4 7/8" 3' - 5 1/4"

2' - 1 1/4"

1'

7/

8" 9'

1/ 4"

2'

1/

4" 1'

3/ 4"

1'

8" 5'

1/ 8"

3'

1/

4" 3'

1/ 8"

MENS

1' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0 1/2" 3' - 0" 3' - 10 3/4" 3' - 0" 3' - 0 1/2" 3' - 0" 3' - 0" 3' - 0"

1' - 6" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 1' - 6"

20' - 10 3/4"

1'

6"

CL

1' - 6"

CL

1' - 6"

3' - 6" 3' - 6"

2' - 11 1/2" 3' - 0" 3' - 0" 3' - 0" 3' - 1" 5' - 4 3/4" 3' - 1" 3' - 0" 3' - 0" 3' - 0"

A-410

F5

F1

F3F7 F7F3

F5

MIR

MIR

MIR

A-410

E3 MIR

5'

0"

5'

0"

RAMP

UP

+211'-7 9/16"

1'

6"

3' - 10 3/4"

5' - 4 3/4"

1' - 6"

2' - 11 1/2"

1' - 5 3/8"

6' - 11 1/4"

3' - 3" 10 7/8" 3' - 3"

3 A

5 A5 A

5 A

9 A

3 A 3 A 3 A

1 A

22 A

3 A 5 A

3 A

5 A

1'

6"

2'

9"3 A

3 A

ELEV LOBBY

CORRIDOR

16 A

3/

4"

8 1/4"

16 A

BCBC

4' - 3 3/4" 1' - 5" 5' - 3 3/4"

A-506

E4

EXTEND

INSULATION 2'-0"

ON SIDE WALL

1' - 7 3/4"

1' - 0 1/2"

25252525

A-504

A7

A7

A-419

E7

A-419

A1

A-419

A5

A-419

A-419

F4

A-419

E9

BL4

A6

A-552

CAP,

QTZ-802.

REFER TO

STRUCTURAL FOR

FLOOR INFILLS.

1 - 111 - 11

FD

FD FD

FD

10"

C L

1'

3"

C L

1'

3"

10"

1 - 17 1 - 71 - 7

1 - 181 - 18

CL

2' - 6"

STAIR 12

- 3

'-1

/1 6"

- 3

'-5

5/

2 1/2"

LIFT GATE BY

MANUFACTURER.

RAMP LANDING.

EXST CONCRETE BEAM.

CORRIDOR

CORRIDOR

WHEELCHAIR

LIFT

4'

1"

4' - 10 1/4"3'

6" 3'

1/ 4"

+212'-1 1/4"

RAMP, SEE

STRUCT DWGS.

CAP, QTZ-802 SST HANDRAIL.

5W FLR +208'-6"

QTZ 802.

BL4

5' - 8"

1"

12"

A7

A-419

A5

A-419

25 A

QTZ-802.

QTZ-802.

PCT-401.

METAL EDGE TRIM,

SCHLUTER SCHIENE

QTZ-802 W/ MTL TRIM @

ALL CORNERS & CAP

PERIMETER.

A5A4.6 A5.1

AB

AC

F4

A-409

EXST LEADER FROM

ROOF ABOVE.

STAIR 1A

FIXED LADDER

W/ ACCESS

HATCH ABOVE.

PENTHOUSE

1' - 2" 13' - 2" 1' - 7" 2' - 1"

1/

2"

3'

5"

UP

3' - 9 1/2" 8' - 5"

SHIPS LADDER

DN TO 4TH FLR.

EOSEOS

INFILL 2'-0"

SQUARE OPENING

W/ MET DECK &

CONC.

PROVIDE 10" +/-

DEEP BY 5'-4" HIGH

BRICK INFILL; FLUSH

W/ ADJ WALL.

EXST GRANITE AND

BRICK BACK-UP

EXTERIOR WALL.

INFILL OPENING W/

MET DECK &

CONC; REFER TO

STRUCT DWGS.

3'

4"

24 A

24 A

24 A

24 A

1/2" GAP MAX.

A1

A-418

3' - 11"

3'

8" 1T

CL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/13/2025 12:19:46 PM

A-413

E N

L A

R G

E D

P L A

N

T

H F

L R

T L

T S

S

T A

IR

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

M K

E

P

C B

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

SCALE: 1/4" = 1'-0"E5

ENLARGED PLAN - STAIR #2 PENTHOUSE LEVEL

SCALE: 1/4" = 1'-0"A1

ENLARGED PLAN - MENS 508 & WOMENS 505

02 4 8134

SCALE: 1/4" = 1'-0"

SCALE: 3/8" = 1'-0"E1

SECTION - WHEELCHAIR LIFT

KEYED NOTES-PLAN

NUMBER COMMENT

1 ALIGN FACE OF PARTITION WITH WINDOW JAMB.

2 ALIGN CENTER OF PARTITION WITH CENTER OF WINDOW MULLION OR

CENTER OF COLUMN.

3 ALIGN FACE OF PARTITION WITH FACE OF PARTITION OR COL

ENCLOSURE.

4 COLUMN ENCLOSURE TO BE PTN TYPE 1 (TYP UNO).

5 ALIGN FACE OF PARTITION WITH CORNER OF EXST WALL(S). PROVIDE

GWB CONTROL JOINT AS REQ'D.

6 EXTERIOR COLUMN ENCLOSURE TO BE PTN TYPE 16 (TYP UNO).

7 ALUM STOREFRONT WINDOW SYSTEM ABOVE.

8 PROVIDE WALL THICKNESS AND FINISH TO MATCH EXISTING. REFER

TO DETAIL B9/A-102.

9 SLAB INFILL AT REMOVAL. SEE STRUCT DWGS.

10 EXPOSED STEEL COLUMN, SEE STRUCTURAL DRAWINGS, PROVIDE

INTUMESCENT COATING ON ALL EXPOSED SURFACES. PNT 906 TYP.

11 PROVIDE GALVANIZED METAL GRATING OVER EXISTING SUBFRAME.

12 ROOF LEADER, SEE PLUMBING DWGS.

13 ELECTRICAL CONDUITS, SEE ELECTRICAL DWGS.

14 CLEAN AND REPAIR GRANITE/ LIMESTONE WALL AND SURROUND

(TYPICAL UNLESS NOTED OTHERWISE).

15 PROVIDE 1" MIN CLOSED CELL FOAM INS AT EXTERIOR WALLS (TYP).

16 PROVIDE RADIANT HEATER ENCLOSURE (SEE SECTION DETAIL).

17 PROVIDE LIMESTONE INFILL AT EXISTING OPENINGS, PATTERN TBD.

SEE D1/A-460 ELEVATION.

18 PROVIDE CLEARANCE (NO OBSTRUCTION OF ANY FIXTURE BEYOND

FINISHED SURFACES) ON BOTH SIZE OF FOLDING PARTITION.

19 PROVIDE LIMESTONE SURROUND ADDITION TO FLOOR MATCH

EXISTING.

20 PROVIDE 4’x8’x3/4” FIRE TREATED PLYWOOD COMMUNICATIONS

BACKBOARD; RUN PANELS WALL TO WALL, ORIENTED VERTICALLY,

PAINT EGGSHELL SHEEN WHITE (DO NOT PAINT OVER FIRE RATING

LABELS).

21 PROVIDE 6"H CONC CURB (HOUSE KEEPING PAD) COORD SIZE &

LOCATION WITH MEP DWGS.

23 PROVIDE 1" AIR SPACE BETWEEN PARTITIONS.

24 1" THICK CLOSED CELL SPRAY FOAM (R-6.3). PROVIDE IGNITION

BARRIER.

25 1" THICK CLOSED CELL SPRAY FOAM (R-6.3).

26 RETURN (1) LAYER 1/2" PLYWOOD & (1) 5/8" GWB TYPE X INTO

OPENING; SHIM PLUMB.

27 PROVIDE HEAD, JAMB, AND SILL RETURNS AT BASEMENT WINDOWS;

5/8" GWB OVER 1/2" PLYWOOD, SHIM PLUMB AND LEVEL.

28 PROVIDE SWITCHABLE PRIVACY GLASS.

29 PROVIDE 16 GA FLUSH, MUD IN OR INLAY ACCESS PANEL. REFER TO

FINISHES. REFER TO PLUMBING DRAWINGS.

30 REFER TO PLUMBING DRAWINGS AND SPEC FOR CLEANOUT COVER.

SCALE: 1/4" = 1'-0"E8

ENLARGED PLAN - PENTHOUSE 601

A

D D

E N

D U

M

/1

/2

File details come from the government source that posted it. Updated .