MH-104_AM 6.pdf
PDF 684 KB Posted
- Solicitation number
- W912DS25RA002
About this file
This document is a detailed HVAC ductwork plan for the second floor of Building 606 at the United States Military Academy at West Point, New York. The architectural drawing (Sheet MH-104) provides a comprehensive layout of ductwork, including specific duct sizes, airflow volumes (ranging from 25 CFM to 500 CFM), and locations for various room types such as instructors' offices, administrative spaces, break areas, and corridors. The plan includes key notes about fire dampers at HVAC chase walls and a stipulation that any substitution of round or rectangular ductwork must receive specific government approval. The project is part of the FY2024 New York District contract (W912DS19C0034), with the current sheet dated 13 May 2025 and reflecting Addendum #6 issued on 10/08/2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B11
B9.8B9.3B8.2
BH
BG
BF
BE
B10B9B8B7B6B5B4B3B2B1C3C2C1
W22
BA
W20 W20
BB
CL2
BC
W18
BD
W19
W21
STAIR 3
ST3
ADMIN
ADMIN
ADMIN
SM CONF
BRK/COPY
ADMIN
CONF COORD
CORRIDOR
STAIR 2
ST2
MENS
JAN
INSTRUCTOR
253A
INSTRUCTOR
253B
INSTRUCTOR
253C
COPY
INSTRUCTOR
250C
OFFICE POD 6
ELECT
INSTRUCTOR
INSTRUCTOR
INSTRUCTOR
HALL
EQUIPMENT STORAGE
ENTRY
HALL
INSTRUCTOR
238A
INSTRUCTOR
238B
INSTRUCTOR
238C
INSTRUCTOR
235C
BREAK AREA
STAIR 3
ST3
DEPT HEAD
DEPT HEAD
ADMIN
DEPT RECEPT
SECRETARY
ADMIN
ADMIN
SM CONF
BRK/COPY
ADMIN
CONF COORD
CORRIDOR
STAIR 2
ST2
WOMENS
JAN
INSTRUCTOR
253A
OFFICE POD 7
INSTRUCTOR
253C
STORAGE
COPY
INSTRUCTOR
250C
INSTRUCTOR
250A
INSTRUCTOR
250B
ELECT
IT
INSTRUCTOR
INSTRUCTOR
STOR
INSTRUCTOR
HALL
EQUIPMENT STORAGE
LOADING DOCK
ENTRY
HALL
INSTRUCTOR
238A
INSTRUCTOR
238B
OFFICE POD 4
INSTRUCTOR
238C
INSTRUCTOR
235C
BREAK AREA
OFFICE POD 5
INSTRUCTOR
235A
INSTRUCTOR
235B
CORRIDOR
75 CFM
CB
(TYP. 2)
50 CFM
CB
50 CFM
CB
50 CFM
CB
40 CFM
CB
65 CFM
CB
1 60 CFM
CB
50 CFM
CB
65 CFM
CB
80 CFM
CB
75 CFM
CB
(TYP. 2)
75 CFM
CB
70 CFM
CB
40 CFM
CB
75 CFM
CB
(TYP. 2)
60 CFM
CB
1 50 CFM
CB
70 CFM
CB
95 CFM
CB
(TYP. 2)
40 CFM
CB
30 CFM
CB
60 CFM
CB
45 CFM
CB
65 CFM
CB
60 CFM
CB
60 CFM
CB
75 CFM
CB
70 CFM
CB
AVB
R1-201
AVB
R1-205
AVB
R1-204
AVB
R1-206 AVB
R1-208
AVB
R1-210
AVB
R1-219
AVB
R1-217
AVB
R1-215
AVB
R1-216
AVB
R1-218
AVB
R1-220
AVB
B1-206
AVB
B1-205
AVB
B1-207
AVB
B1-208
AVB
B1-204
A8
M-302
A6
M-302
6 5
BREAK AREA
ER-1
65 CFM
ER-1
80 CFM
ER-1
75 CFM
ER-1
70 CFM
ER-1
150 CFM
ER-1
60 CFM
ER-1
65 CFM
ER-1
150 CFM
ER-1
60 CFM
ER-1
150 CFM
ER-1
50 CFM
(3)ER-1
100 CFM
(3)ER-1
100 CFM
ER-1
60 CFM
ER-1
75 CFM
ER-1
45 CFM
ER-1
65 CFM
ER-1
60 CFM
ER-1
60 CFM
ER-1
190 CFM
ER-1
70 CFMRR-2
50 CFM
RR-1
275 CFM
RR-2
50 CFM
ER-1
75 CFM
B11.1
AVB
R1-202
AVB
R1-203
AVB
R1-207
AVB
R1-209
AVB
R1-211
AVB
R1-212
AVB
R1-213
AVB
R1-214
75 CFM
CB
(TYP. 2)
4"x6"
6" x4
8" x8
10"x8"
4"x6"
16"x10"
6"x4"
12"x4"
10"x6"
14"x4" 8" x6
6"ø
4"x4"
12"x8"
12"x10"
6" ø
8"x8"
8" x8
6" ø
6"x4"6"ø
6"ø
6" ø
8" x8
16"x10"
6"x4"
6"ø
8" x8
6" ø
8" x8
20"x10"
20"x12"
6"ø 8"x6"
6" ø
8"x8"
18"x14" CB S/A
14"x10"
28"x12"
10"x4"
8"x8"
6" ø
"x
"x
8" 8" x8
6" x8
6"ø
4" x6
6"ø
4"x8"
6"x4"
14"x4"
8" x8
6" ø
6"x8"
14"x4"
6"x4"
"x
4"
8"x6"
10"x10"
8" x8
8"x6"
6" x6
6"x4"
8"x6"
8"x6"
8"x8"
6" x6
6"x4"
6"x4"
14"x10" 18"x10" 20"x10"
8"x8"
8"x6"
6" x4
"x
6"
8"x6" 8"x8"
6" x6
6"x4"
6"x4"
"x
10"x4"
6" x4
6"x6"
6" x4
8"x6"
"x
8"
10"x4"
6" x4
6" x4
6"x6"
8" x6
10"x4"
6"x4"
6"x6"
6" x6
6" ø
6"ø
6" x8
CD-1
75 CFM
SR-1
25 CFM
6"x4" S/A
8" x4
10"x4" 8"x10"
8"ø
LSD-1
150 CFM
LSD-1
150 CFM
10"x10" S/A
SR-1
25 CFMSR-1
25 CFM CD-1
40 CFM
SR-1
25 CFM
12"x10" S/A
6"ø
CD-1
70 CFM
CD-1
40 CFM
LSD-1
150 CFM
14"x10" 18"x10" 18"x12"
22"x12"
CD-1
115 CFM
6" ø
CD-1
110 CFM
6"x8"
10"x6" 10"x8"
6"ø
LSD-1
65 CFM
10"x8"
LSD-1
150 CFM8"ø12"x4"
6"ø S/A
6" ø (2)CD-1
75 CFM
8"x8"
CD-1
50 CFM6"x4" 6"ø
LSD-1
75 CFM
6" x8
LSD-1
75 CFM
6" ø
LSD-1
80 CFM
RR-1
500 CFM
6"x6" 8"x8"
10"x8" 10"x8"
"x
14"x10"
18"x8"
8"x4" E/A
6"x6"
16"x10"
6"x6"
8"x10"
6" ø
6"ø
6" ø
6"ø
12"x4"
6" ø
6"x4"
8"x12" OA UP
TO GRV-3-1
12"x12" EA W/
WMS UP TO
EF-3-1
12"x8"
04 8 16268
SCALE: 1/8" = 1'-0"
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-M20.rvt
10/3/2025 2:08:56 PM
MH-104
S E
C O
N D
F L O
O R
P L A
N W
E S
T
D U
C T
W O
R K
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T N
Y P
N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T A
K
A K
J F
M
A Y
W D
S C
E C
REV RTA SUBMISSION
R E
P A
IR
B
L D
G
G
E N
E R
A L I N
S T
R U
C T
IO
N
B L D
G
SCALE: 1/8" = 1'-0"A1
SECOND FLOOR PLAN DUCTWORK - WEST
KEYNOTE - MH-104
1 28"x20" CB S/A UP & 24"x14" CB S/A DOWN
2 FIRE DAMPER AT HVAC CHASE WALL. PROVIDE FOR ALL DUCTWORK THAT PENETRATES FIRE RATED PARTITION.
3 26"x18" CB E/A UP & 20"x14" CB E/A DOWN
4 24"x16" E/A UP & 22"x14 E/A DOWN
5 38"x20" S/A UP & 46"x20" S/A DOWN
6 24"x18" R/A UP & 30"x18" R/A DOWN
GENERAL NEW WORK NOTES:
1. SUBSTITUTION FOR ROUND OR RECTANGULAR DUCTWORK
FROM WHAT IS SHOWN ON PLAN MUST RECEIVE SPECIFIC
GOVERNMENT APPROVAL.
A
D D
E N
D U
M
/0
/2
File details come from the government source that posted it. Updated .