This document is a technical architectural drawing set (Sheet A-314) containing detailed section details for a building construction project, specifically for West Point Building 606. The drawings provide cross-sectional views of multiple architectural elements including curtain wall systems, canopy details, sliding door sill, infill roof, and floor interfaces. Key technical specifications include:
Architectural components feature multiple layers of construction materials such as rigid insulation (R-12 to R-30), exterior gypsum sheathing, membrane air barriers, metal studs, curtain wall clip systems, and various flashing and sealing techniques. The drawings show intricate details for structural interfaces, including steel beams, concrete slabs, HVAC equipment placement, and thermal/moisture protection strategies. Specific details are provided for floor levels ranging from first floor (159'-3") to top of structure (221'-10"), with precise measurements and material specifications for each section.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TOSL-2ND FLR (172'-3")
13' - 0"
CEILING, AS
SCHEDULED.
BACKER ROD &
SEALANT; EA SIDE (TYP).
SHIM.
FLOORING, AS
SCHEDULED.
CURTAIN WALL
SYSTEM; REFER
TO
ELEVATIONS.
BACKER ROD &
SEALANT.
SHIM.
STEEL BENT PLATE, SEE
STRUCT DWGS.
STEEL BEAM; SEE
STRUCT DWGS,
PROVIDE REQD
FIREPROOFING (TYP).
MCM PANELS ON MCM
CLIP SYSTEM.
PRE-FINISHED
METAL
FLASHING;
INSTALL INTO
MCM CLIP
SYSTEM.
COLD FORMED
FRAMING; REFER TO
STRUCT DWGS.
2-1/2" RIGID INSULATION
(R-15).
FLUID APPLIED
MEMBRANE AIR
BARRIER.
COLD FORMED
FRAMING CONT
CORNER (TYP).
1/2" EXTERIOR GYPSUM
SHEATHING.
MEMBRANE FLASHING.
2-1/2" RIGID INSULATION
(R-15).
CONT 2X WOOD
BLOCKING.
CONC SLAB ON METAL
DECK; SEE
STRUCTURAL DWGS.
C U
R T
A
IN
W A
LL
O
P E
N
IN
G
3/ 4"
3/ 4"
C U
R T
A
IN
W A
LL
F
R A
M E
2' - 2 3/4"
HVAC EQUIP; SEE
MECHANICAL DWGS.
DEFLECTION TRACK
(TYP UNO).
PROVIDE BENT STL
PLATE CLIPS @ 48" OC
MIN. ATTACH TO STL
BEAMS PRIOR TO
FIREPROOFING FOR
PARTITION
ATTACHMENT (TYP).
E N
T R
Y S
Y S
T E
M O
P E
N
IN
G
E N
T R
Y S
Y S
T E
M F
R A
M E
1/ 2"
3'
6"
3 1/2" UNFACED
MINERAL WOOL SOUND
BATT INS.
ENTRY SYSTEM
TRANSOM WINDOWS.
ENTRY SYSTEM
DEFLECTION HEAD.
ENTRY SYSTEM
AUTOMATIC DOORS.
1' - 0"
MEMBRANE
FLASHING.
TOSL-1ST FLR (159'-3")
0"
CONCRETE WALKWAY;
REFER TO SITE
DRAWINGS.
VEST
SEALANT, TYP.
FLOORING, AS
SCHEDULED.
CONCRETE SLAB; SEE
STRUCTURAL DWGS.
1/2" COMPRESSIBLE
FILLER; FULL DEPTH.
THERMALLY BROKEN
ALUMINUM THRESHOLD;
SET IN FULL BED OF
SEALANT.
2" RIGID INSULATION
(R-12 MIN).
CONCRETE FOUNDATION WALL; SEE
STRUCTURAL DRAWINGS.
ENTRY SYSTEM
AUTOMATIC DOORS.
TOS - INFILL (221'-10")
62' - 7"
2X CONT WD NAILERS;
MATCH INS & COVER
BOARD THICKNESS.
BACKER ROD &
SEALANT.
5" ± RIGID INS (AVG R-30); (2) LAYERS
MIN, STAGGER JOINTS.
5/8" COVER BOARD.
MODIFIED BITUMEN ROOF SYSTEM.
2" RIGID INSULATION (R-12 MIN).
CONTINUOUS 3/4" PLYWOOD.
STEEL PLATE; SEE STRUCT DWGS.
1/2" EXTERIOR GYPSUM SHEATHING.
5/8" COVER BOARD.
STEEL BENT PLATE, SEE STRUCT
DWGS.
STEEL BEAM; SEE STRUCT DWGS,
PROVIDE REQD FIREPROOFING
(TYP).
CEILING, AS
SCHEDULED.
ELEV LOBBY
6" METAL STUD, SEE STRUCT DWG.
CURTAIN WALL CLIP
SYSTEM; ATTACH TO
STRUCTURE.
CUSTOM CURTAIN WALL
AIRFOIL CAP (BID
OPTION #2).
C U
R T
A
IN
W A
LL
F
R A
M E
3/ 4"
1/
4" 8"
CURTAIN WALL SYSTEM;
REFER TO ELEVATIONS.
TOP OF BLOCKING ( 223' - 5" )
64' - 2"
CONC SLAB ON METAL DECK; SEE
STRUCTURAL DWGS.
1" 1"
1/2" / 12"
STRIPPING.
ELASTOMERIC
MEMBRANE FLASHING
SHEETING; SET IN
ADHESIVE.
ELASTOMERIC MEMBRANE FLASHING
SHEETING; SET IN ADHESIVE.
TAPERED RIGID
INSULATION (R-10 MIN).
INSULATED SPANDREL
PANEL; SEAL FULL
PERIMETER AT CURTAIN
WALL FRAME (TYP).
PROVIDE MET SKIN TO
MATCH CURTAIN WALL
WHEN EXPOSED TO
INTERIOR (TYP)
INS SPANDREL
GLAZING; SEE EL'S.
C U
R T
A
IN
W A
LL
F
R A
M E
FLUID APPLIED MEMBRANE BARRIER;
FLASH & LAP OVER VAPOR
RETARDER & SEAL (TYP).
VAPOR RETARDER; CONTINUE UP
PTN 2" MIN (TYP UNO).
FILL VOID W/ MINERAL
WOOL INSULATION.
PRE-FINISHED METAL
FASCIA; MATCH
CURTAIN WALL FRAME
COLOR.
FILL CAVITIES W/ MINERAL WOOL INSUL.
TOSL-5W FLR (208'-6")
49' - 3"
FLOORING, AS
SCHEDULED.
CONCRETE SLAB; SEE
STRUCTURAL DWGS.
CEILING, AS
SCHEDULED.
CURTAIN WALL SYSTEM;
REFER TO ELEVATIONS.
CUSTOM CURTAIN WALL
AIRFOIL CAP (BID
OPTION #2).
POUR STOP; REFER TO
STRUCT DWGS.
STEEL BEAM; SEE
STRUCT DWGS,
PROVIDE REQD
FIREPROOFING (TYP).
FIRE SAFING (TYP @
EACH FLOOR LINE).
INS SPANDREL
GLAZING; SEE EL'S.
INSULATED SPANDREL
PANEL; SEAL FULL
PERIMETER AT CURTAIN
WALL FRAME (TYP).
PROVIDE MET SKIN TO
MATCH CURTAIN WALL
WHEN EXPOSED TO
INTERIOR (TYP)
1 1/2"
HVAC EQUIP; SEE
MECHANICAL DWGS.
CURTAIN WALL CLIP
SYSTEM; ATTACH TO
STRUCTURE.
BE
5/8" COVER BOARD.
FILL CAVITY WITH BATT
INSULATION
5" ± RIGID INS (AVG
R-30); (2) LAYERS MIN,
STAGGER JOINTS.
EXST CONCRETE ROOF
DECK.
5/8" COVER BOARD.1' - 10 1/2" 1' - 10 1/2"
3' - 9"
2" RIGID INSULATION
(R-12 MIN).
MODIFIED BITUMEN
ROOF SYSTEM.
STEEL BEAM; SEE
STRUCT DWGS,
PROVIDE REQD
FIREPROOFING (TYP).
STRIPPING.
CANT STRIP.
1/2" / 12"
ELASTOMERIC
MEMBRANE FLASHING
SHEETING; SET IN
ADHESIVE.
CONC OVER METAL
DECK; REFER TO
STRUCT DWGS.
STEEL BENT PLATE, SEE
STRUCT DWGS.
(2) LAYERS 5/8" TYPE X EXT
SHEATHING (ULV297 - 1 HR)
TOS
223' - 8"
2'
2"
/2
HPT
224' - 6 1/2"
VAPOR RETARDER;
CONTINUE UP PTN 2"
MIN (TYP UNO).
FLUID APPLIED MEMBRANE BARRIER;
FLASH & LAP OVER VAPOR
RETARDER & SEAL (TYP).
VAPOR RETARDER; EXTEND DOWN
WALL 2" & LAP AIR BARRIER.
TOS - INFILL (221'-10")
62' - 7"
FOR ITEMS NOT NOTED;
/SEE D1 A-314
1/2" EXTERIOR GYPSUM
SHEATHING.
COLD FOREMED METAL
FRAMING; REFER TO STRUCT
DWGS. FILL CAVITIES W/
MINERAL WOOL INSULATION.
1" RIGID INSULATION
(R-6).
MCM PANELS ON MCM
CLIP SYSTEM.
MCM SYSTEM @ CURTAIN
WALL (BEYOND).
PRE-FINISHED METAL
FASCIA (BEYOND).
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt
10/13/2025 2:32:45 PM
A-314
W A
L L
S E
C T
IO
N
S
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T
N Y
P N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
N
Y
W D
R
E A
L
M P
K
V N
S
E P
T E
M B
E R
W
D
S
C
Q P
K J
O B
N O
.0
ADDENDUM #6
R E
P A
IR
B
L D
G
G E
N E
R A
L I N
S T
R U
C T
IO
N
B L
D G
SCALE: 1 1/2" = 1'-0"C4
SECTION DTL - CURTAIN WALL CANOPY (SOUTH)
SCALE: 1 1/2" = 1'-0"A4
SECTION DTL - SLIDING DOOR SILL
SCALE: 1 1/2" = 1'-0"D1
SECTION DTL - INFILL ROOF @ CURTAIN WALL (SOUTH)
SCALE: 1 1/2" = 1'-0"A1
SECTION DTL - INFILL CURTAIN WALL @ FLOOR
SCALE: 1 1/2" = 1'-0"A8
SECTION DTL - ROOFTOP BEAM INSULATION
A
D D
E N
D U
M
/1
/2
SCALE: 1 1/2" = 1'-0"E8
SECTION DETAIL - RAINSCREEN TRANSITION @ ROOF
File details come from the government source that posted it. Updated .