MP-101_AM 6.pdf
PDF 1 MB Posted
- Solicitation number
- W912DS25RA002
About this file
This document is a mechanical piping plan sheet (MP-101) for a renovation project at the United States Military Academy, West Point, NY. The detailed first floor plan shows an extensive piping layout for Building 606, a General Instruction Building, with complex pipe routing for hot water supply (HWS), hot water return (HWR), chilled water supply/return (CHWS/CHWR), and various drain lines. The project is part of the FY2024 New York District construction effort, with the contract number W912DS19C0034 and a submission date of 13 May 2025. The plan includes multiple classroom, collaboration, and support spaces, with intricate piping connections to various mechanical equipment like fan coil units (FCU), air handling units, and circulation systems, using pipe sizes ranging from 3/4" to 6" in diameter.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
TT
TT
T T T T
T
T
TTTTT
T
T
T
T
T
T
T
T
D5W29D4D3D2D1
AE
AD
CL1
AC
AB
AA
A6A5.1A5A4.6A4.4
A4.4
A4.2A4A3.7A3.2A3A2.7A2A1.9A1.5A1.3A1
COLLAB
CLASSROOM
CLASSROOM
VEST
STOR
COLLAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
VEST
ELEV LOBBY
HC TLT
WELLNESS RM
WATER SERVICE & BACKFLOW
PREVENTER
FIRE PUMP
CONF
ELECT
114 CLASSROOM
CLASSROOM
CLASSROOM
COLLAB
COLLAB
COLLAB
CLASSROOM
VEST
CB
1 GPM
(TYP. 4)
6.1 MBH
CB
1.5 GPM
(TYP. 4)
6.7 MBH
CB
1 GPM
5.1 MBH
CB
1 GPM
4.8 MBH
CB
.75 GPM
3.7 MBH
CB
.75 GPM
5.3 MBH
CB
.75 GPM
3.8 MBH
CB
1 GPM
(TYP. 4)
4.5 MBH
CB
1 GPM
(TYP. 4)
4.5 MBH
CB
1 GPM
(TYP. 4)
4.5 MBH
CB
.75 GPM
(TYP. 4)
3.9 MBH
CB
.5 GPM
3.4 MBH
CB
.75 GPM
(TYP. 4)
3.9 MBH
CB
1 GPM
(TYP. 4)
5 MBH
CB
1 GPM
(TYP. 4)
4.5 MBHCB
1 GPM
(TYP. 4)
4.5 MBH
CB
1 GPM
(TYP. 4)
4.9 MBH
CB
1 GPM
(TYP. 4)
5.3 MBH
AVB
B1-103
COLLAB
CUH
1-3
CUH
1-1
CUH
1-2
UH
1-1
COLLAB
SS
1-1
3" CBS/R UP
6" CBS/R DOWN
6"ø CBS
6"ø CBR
6"ø CBR 6"ø CBS
1"ø CBS 1"ø CBR 2 1/2"ø CBS
1 1/2"ø CBS
1 1/2"ø CBR
2"ø CBS 2"ø CBR
1 1/2"ø CBR 1 1/2"ø CBS
1"ø CBS 1"ø CBR
1 1/2"ø
1 1/2"ø
3/ 4" ø 3/
4" ø
1 1/4"ø CBS
1 1/4"ø CBR
1"ø CBS
1"ø CBR
1"ø CBS
3/4"ø CBR
3/4"ø CBS
3/4"ø CBR
1 1/4"ø CBR
1 1/4"ø CBS
1" ø
1 1/4"ø CBR 1 1/4"ø CBS
AVB
B1-101
AVB
B1-102
CORR
CORR
CORR
HC TLT
2"ø HWR 2"ø HWS
1 1/4"ø HWR 1 1/4"ø HWS
1"ø HWS
1 1/4"ø HWR
1 1/4"ø HWS
4"ø CHWS
4"ø CHWR
1 1/2"ø HWR
A6
M-301
A8
M-301
1" ø
3/ 4" ø
3/ 4" ø
1" ø
3/ 4" ø
3/ 4" ø 3/
4" ø
FTR-A
2.1
4' - 4"
0.2
FTR-B
2.1
4' - 2"
0.2
FTR-B
2.1
4' - 4"
0.2
FTR-A
1.9
4' - 4"
0.1
FTR-A
1.9
4' - 4"
0.1
FTR-A
1.9
4' - 4"
0.1
FTR-A
2.8
5' - 10"
0.2
FTR-A
3.4
8' - 0"
0.2
FTR-A
3.7
8' - 0"
0.3
FTR-A
4' - 0"
0.1
FTR-A
1.6
5' - 0"
0.1
FTR-B
2.5
4' - 11"
0.2
FTR-A
3' - 11"
0.1
FTR-B
5' - 6"
0.3
FTR-B
5' - 6"
0.3
FTR-B
5.8
8' - 0"
0.4
FTR-B
5.35
7' - 4"
0.4
FTR-B
3.7
5' - 1"
0.3
FTR-B
3.7
5' - 1"
0.3
FTR-B
6' - 0"
0.2
3/4" HWR UP
3/4" HWS UP
3/4" HWS UP
3/4" HWR UP
3/4" HWR UP
3/4" HWR UP
3/4" HWS UP
3/4" HWR UP
3/4" HWS UP
3/4" HWS UP
3/4" HWR UP
3" HWS/R UP
4" HWS/R DOWN
3/4" HWS UP
3/4" HWR UP
3/4" HWS UP
3/4" HWR
UP
3/4" HWR UP
2 1/2"ø CBR
1"ø CBR
1"ø CBS
BE.3
BF.7
BB.1
BB.9
A1.1B12B11.1
4" CHWS/R UP
4" CHWS/R DOWN
FTR-A
2.5
5' - 0"
0.2
AVB
R2-103
AVB
R2-107
AVB
R2-109
AVB
R2-113 AVB
R2-112
RS/RL
UP
CB
1 GPM
5.1 MBH
3/4" HWS DW
3/4" HWR DW
3/4" HWS UP
3/4" HWR UP
3/4" HWS DW
3/4" HWR DW
3/4" HWS DW
3/4" HWR UP
3/4" HWS UP
3/4" HWR DW
3/4" HWS UP
3/4" HWR DW
3/4" HWS UP
3/4" HWS DW
3/4" HWR DW
3/4" HWR UP
3/4" HWS UP
3/4" HWS DW
3/4" HWR DW
3/4" HWR UP
3/4" HWR UP
3/4" HWS UP
3/4" HWS DW
3/4" HWS DW
3/4" HWR DW
3/4" HWS UP
3/4" HWS UP
3/4" HWR UP
3/4" HWS UP
3/4" HWR UP
1 1/4" HWS/R
1 1/4" CBS/R
1 1/4" CBS/R
3/4" HWS/R
COLLAB
ESS
ATFP EMERGENCY
SHUTDOWN SWITCH
FCU
1-1
1" ø
1" ø
1" ø
1" ø
3/4" D DN
TO FD
(BOTTOM)
(BOTTOM)
3/4" HWS/R UP &
3/4" CHWS/R UP &
3/4" DRAIN UP
3/4" HWS/R UP &
3/4" CHWS/R UP &
3/4" DRAIN UP
3/4" HWS/R UP &
3/4" CHWS/R UP &
3/4" DRAIN UP
3/4" HWS/R UP &
3/4" CHWS/R UP &
3/4" DRAIN UP
3/4"ø HWS3/4"ø HWR
3/4"ø HWS
1" ø
H W
S 1" ø H
W R
2"ø HWR 2"ø HWS
3/4" HWS UP
FTR-A
0.8
2' - 0"
0.5
FTR-A
1.9
4' - 4"
0.1
FTR-A
1.9
4' - 4"
0.1
FTR-S
2.1
4' - 4"
0.2
FTR-R
2.1
4' - 1"
0.2
FTR-A
2.1
4' - 4"
0.2
FTR-B
3.7
5' - 1"
0.3
FTR-B
3.7
5' - 1"
0.3
FTR-B
5.35
7' - 4"
0.4
FTR-B
5.35
7' - 4"
0.4
FTR-B
5.35
7' - 4"
0.4
FTR-B
2.5
4' - 11"
0.2
FTR-B
1.7
3' - 4"
0.1
3/4"ø CHWR
3/4"ø CHWS
3/4"ø D
1"ø CHWR
1"ø CHWS
1" CHWS/R DN &
1" DRAIN DN
1"ø HWR
1" ø
D
1-1/4" D UP & DN
3/4"ø CBS
3/4"ø CBR
3/4"ø CBS 3/4"ø CBR
3/4"ø CBS
3/4"ø CBR
AVB
R2-111
04 8 16268
SCALE: 1/8" = 1'-0"
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-M20.rvt
10/3/2025 2:09:02 PM
MP-101
F
IR
S T
F L O
O R
P L A
N E
A S
T
P
IP
IN
G
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T N
Y P
N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T A
K
A K
J F
M
A Y
W D
S C
E C
REV RTA SUBMISSION
R E
P A
IR
B
L D
G
G
E N
E R
A L I N
S T
R U
C T
IO
N
B L D
G
SCALE: 1/8" = 1'-0"A2
FIRST FLOOR PLAN PIPING - EAST
GENERAL NEW WORK NOTES:
1. PIPING PLANS DO NOT SHOW WALL RATINGS. REFER TO LIFE
SAFETY PLANS FOR WALL RATING INFORMATION.
2. INCLUDE SHUT-OFF VALVES AT ALL BRANCHES. USE 1/4-TURN
BALL VALVES WHEN 3" DIAM. AND SMALLER.
A
D D
E N
D U
M
/0
/2