This document is an architectural floor plan drawing for Building 606 at West Point, specifically showing the First Floor Plan - West. The detailed blueprint includes precise measurements, room layouts, and technical specifications for various spaces such as classrooms, restrooms, storage areas, electrical and IT rooms. The floor plan is drawn at 1/8" = 1'-0" scale and includes additional detailed views of typical partition and column configurations. The drawing provides comprehensive architectural information including room numbers (140-159), room dimensions, floor area calculations (e.g., 1,082 SF unexcavated area), and specific construction details like closed cell foam insulation requirements and interior wall treatments. The document appears to be part of a construction or renovation project for the U.S. Army Corps of Engineers, with the file dated 10/13/2025 and created using Autodesk software.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C2 C3 B2 B3 B4 B5 B6 B7 B8 B9
B8.2 B9.3 B9.8
B10
B11
B11
W18
W19
W20
W21
W22
BABA
BBBB
BD BE
BF
BG
BH
CL2
A-203
C1
A-205
C1
M A
T C
H L
IN
E
A
A -1
17' - 1" 15' - 10" 13' - 11" 13' - 11" 13' - 11" 15' - 2" 15' - 6 1/2" 12' - 1" 12' - 5" 17' - 3" 12' - 7"
E1
A-301
____________ E1
A-301
C1
A-303
C1
A-303
ELEV LOBBY
CORRIDOR
WOMENS
JAN
HC SHR/TLT
MENS
144CLASSROOM
CLASSROOM
STORAGE
ELECT
IT
HALL
CLASSROOM
152 CLASSROOM
CLASSROOM
CLASSROOM
HALL
OFFICE
STORAGE
WOMENS
MENS
1,082SF ± UNEXCAVATED;
PROVIDE CLOSED CELL SRPAY
FOAM INSULATION & IGNITION
BARRIER ON UNDERSIDE OF
FLOOR ABOVE (R-12.5 MINIMUM).
142143
146147
14 A
14 A
14 A
14 A
15 A
6 A
9 A
9 A
9 A
16 A
16 A
16 A
14 A
14 A
14 A
4 A
STAIR 2
ST2
1 A
TYP
TYP
A-410
A1
A-415
A1
C1
A-304
C5
A-303
16 A 16 A
A-452
A1
B1
16 A
9 A
14 A
EXST WALLS.
2'
1/
2"
/2
7"
1"
9'
1/
2" 8'
/2
4'
1' - 3" 141' - 4 1/2"
14' - 4 1/2" 10' - 0" 14' - 4 1/2"
41' - 0"
24' - 4"
140A 140B
1/ 2"
/2
1'
1/
2"
5'
6"
STAIR 18
DF/BF12
1'
6"
7'
BL6
BL5
BL13
8 3/4"
A-510
A1
2 - 5
2 - 5
2 - 5
2 - 3 2 - 3 2 - 3 2 - 3 2 - 32 - 3
2 - 3
2 - 1A
A1
A-303
4 A
16 A
4 A
14 A
2 - 3
UP
CLASSROOM
7"9"
± 10 1/4" 28' - 3 7/8" 28' - 6 1/2" 28' - 10"
± 9"30' - 4 3/8"30' - 11"6' - 10"16' - 1 7/8"10 1/4" ± ± 8" 26' - 4"
30' - 4 3/8"
5/
8"
/4
9'
/2
/2
1/
8"
1/
8"
/2
/8
8'
7'
A-466
E6
A-465
C6
C2
A6
A2 A-465 A2C2A-466
E2
A6
2' - 2 5/8" 2' - 11 1/8" 11 3/4"A-465 A2C2
A6
A-466
C6
C2 A-466 A2
A6 A-466
C6
C2 A2
A6
2 - 7 2 - 5 2 - 72 - 5
2 - 5
(X3)
2 - 7
2 - 5
2 - 7
2 - 52 - 7
2 - 5
(X3)
2 - 5
(X3)
2 - 7
2 - 72 - 52 - 7 2 - 5
2 - 7 2 - 5
(X3) 2 - 5
2 - 5 2 - 7
2 - 7 2 - 5 2 - 72 - 5
2 - 5
(X3)
2 - 7
(X3) 2 - 5
2 - 7 2 - 5 2 - 5
2 - 7
2 - 5 2 - 7 2 - 5
2 - 5
(X2)
2 - 7 2 - 5(X4)
2 - 7
2 - 5
(X3) (X3)
(X4)
2 - 72 - 7
2 - 5
(X2)
2 - 7
2 - 5 2 - 7
A-467
G3
G7
E3
E7 A-467C7
C3
A7
A3+ 159' - 3"
+ 159' - 3"
(22) (16)(8) (36) (22) (40) (24)
(60)
(32)2 - 3
1' - 3" 17' - 8 1/2" 19' - 0" 52' - 6 1/2" 12' - 3"
2' - 2 1/2"
1 A
159A
2 - 52 - 7 2 - 5 2 - 7
2 - 52 - 52 - 7 2 - 7 2 - 5
2 - 7
2 - 72 - 5
2 - 52 - 5
2 - 7
2 - 5 2 - 7 2 - 7
2 - 5
E - 2 E - 2
(X3)
(X2)
(X2)
(X3)
BCBC
A-102
A3
TYP
A-102
A3
TYP
A-102
A1
TYP
CORNER
E - 2
2 - 1B
2 - 1A
A-206 D6
LOUVER
LOUVER LOUVER
16 A16 A
16 A
EXST UNEXCAVATED
CRAWLSPACE 188
EXST UNEXCAVATED
CRAWLSPACE
EQ
EQ
EQ
E - 2 E - 2E - 2
E - 2
(ABV)
(ABV)
9A
14A
14 A
ABOVE
1'
3"
E4
A-564
LOUVER
NORTH
LOADING DOCK CONNECTOR
EAST
EAST
(1 STORY)
WEST
SE
E
PL
AN
VA
R
IE
S;
EX
ST
E
XT
ER
IO
R W
AL
L
CLCL
2'-0" MAX @ COLUMN
1' - 9 1/2" ±
PARTITION; AS
SCHEDULED.
CONTINUE PARTITION
GWB PAST COLUMN; IF
STUD SPACING IS >2'-0",
PROVIDE 2 1/2" FRAMING.
EXISTING COLUMN.
EXISTING MASONRY
WALL.
C
LE
AR
1"
1" CLOSED CELL SPRAY
POLYURETHANE FOAM
INSULATION (R-6.3); FULL
PERIMETER OF COLUMN.
EXST EXTERIOR WALL
SEE PLAN
VARIES;
EX
ST
E
XT
ER
IO
R W
AL
L
SE
E
PL
AN
VA
R
IE
S;
EXISTING COLUMN.
EXISTING MASONRY
WALL.
1" CLOSED CELL SPRAY
POLYURETHANE FOAM
INSULATION (R-6.3); FULL
PERIMETER OF COLUMN.
PARTITION; AS
SCHEDULED.
8' -0
D O
O R
O
PE
N
IN
G S
VA
R
IE
S
(V
IF
4'
-0
W
D W
REMOVE EXST SILL AT
WDW OPEING INFILLS;
REPLACE W/ (3)
COURSES OF BRICK TO
MATCH EXST.
INFILL; PROVIDE BRICK
BACKUP AND VENEER TO
MATCH EXST.
EXST LINTEL / HEADER
TO REMAIN.
PROVIDE CMU AT
AREAWAY INFILL.
NOTE: PROVIDE WATERPROOFING
& 1/2" DRAINAGE BOARD AT BELOW
GRADE INFILL.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt
10/13/2025 2:31:24 PM
A-102
F
IR
S T
F L
O O
R P
L A
N
W E
S T
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T
N Y
P N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
N
Y
E P
M
K
S M
S
M P
K
V N
S
E P
T E
M B
E R
W
D
S
C
Q P
K J
O B
N O
.0
ADDENDUM #6
R E
P A
IR
B
L D
G
G E
N E
R A
L I N
S T
R U
C T
IO
N
B L
D G
SCALE: 1/8" = 1'-0"C1
FIRST FLOOR PLAN - WEST
SCALE: 1" = 160'-0"
KEY PLAN - WEST
KEYED NOTES-PLAN
NUMBER COMMENT
1 ALIGN FACE OF PARTITION WITH WINDOW JAMB.
2 ALIGN CENTER OF PARTITION WITH CENTER OF WINDOW MULLION OR
CENTER OF COLUMN.
3 ALIGN FACE OF PARTITION WITH FACE OF PARTITION OR COL
ENCLOSURE.
4 COLUMN ENCLOSURE TO BE PTN TYPE 1 (TYP UNO).
5 ALIGN FACE OF PARTITION WITH CORNER OF EXST WALL(S). PROVIDE
GWB CONTROL JOINT AS REQ'D.
6 EXTERIOR COLUMN ENCLOSURE TO BE PTN TYPE 16 (TYP UNO).
7 ALUM STOREFRONT WINDOW SYSTEM ABOVE.
8 PROVIDE WALL THICKNESS AND FINISH TO MATCH EXISTING. REFER
TO DETAIL B9/A-102.
9 SLAB INFILL AT REMOVAL. SEE STRUCT DWGS.
10 EXPOSED STEEL COLUMN, SEE STRUCTURAL DRAWINGS, PROVIDE
INTUMESCENT COATING ON ALL EXPOSED SURFACES. PNT 906 TYP.
11 PROVIDE GALVANIZED METAL GRATING OVER EXISTING SUBFRAME.
12 ROOF LEADER, SEE PLUMBING DWGS.
13 ELECTRICAL CONDUITS, SEE ELECTRICAL DWGS.
14 CLEAN AND REPAIR GRANITE/ LIMESTONE WALL AND SURROUND
(TYPICAL UNLESS NOTED OTHERWISE).
15 PROVIDE 1" MIN CLOSED CELL FOAM INS AT EXTERIOR WALLS (TYP).
16 PROVIDE RADIANT HEATER ENCLOSURE (SEE SECTION DETAIL).
17 PROVIDE LIMESTONE INFILL AT EXISTING OPENINGS, PATTERN TBD.
SEE D1/A-460 ELEVATION.
18 PROVIDE CLEARANCE (NO OBSTRUCTION OF ANY FIXTURE BEYOND
FINISHED SURFACES) ON BOTH SIZE OF FOLDING PARTITION.
19 PROVIDE LIMESTONE SURROUND ADDITION TO FLOOR MATCH
EXISTING.
20 PROVIDE 4’x8’x3/4” FIRE TREATED PLYWOOD COMMUNICATIONS
BACKBOARD; RUN PANELS WALL TO WALL, ORIENTED VERTICALLY,
PAINT EGGSHELL SHEEN WHITE (DO NOT PAINT OVER FIRE RATING
LABELS).
21 PROVIDE 6"H CONC CURB (HOUSE KEEPING PAD) COORD SIZE &
LOCATION WITH MEP DWGS.
23 PROVIDE 1" AIR SPACE BETWEEN PARTITIONS.
24 1" THICK CLOSED CELL SPRAY FOAM (R-6.3). PROVIDE IGNITION
BARRIER.
25 1" THICK CLOSED CELL SPRAY FOAM (R-6.3).
26 RETURN (1) LAYER 1/2" PLYWOOD & (1) 5/8" GWB TYPE X INTO
OPENING; SHIM PLUMB.
27 PROVIDE HEAD, JAMB, AND SILL RETURNS AT BASEMENT WINDOWS;
5/8" GWB OVER 1/2" PLYWOOD, SHIM PLUMB AND LEVEL.
28 PROVIDE SWITCHABLE PRIVACY GLASS.
29 PROVIDE 16 GA FLUSH, MUD IN OR INLAY ACCESS PANEL. REFER TO
FINISHES. REFER TO PLUMBING DRAWINGS.
30 REFER TO PLUMBING DRAWINGS AND SPEC FOR CLEANOUT COVER.
04 8 16268
SCALE: 1/8" = 1'-0"
CR
SCALE: 1 1/2" = 1'-0"A3
PLAN DETAIL - TYP PTN PAST COLUMN WEST
SCALE: 1 1/2" = 1'-0"A1
PLAN DETAIL - TYP CORNER COLUMN
SCALE: 1 1/2" = 1'-0"B9
SECT DET - TYP BRICK INFILL
A
D D
E N
D U
M
/2
/2
A
D D
E N
D U
M
/1
/2