About this file

This document is an architectural floor plan drawing for Building 606 at West Point, specifically showing the First Floor Plan - West. The detailed blueprint includes precise measurements, room layouts, and technical specifications for various spaces such as classrooms, restrooms, storage areas, electrical and IT rooms. The floor plan is drawn at 1/8" = 1'-0" scale and includes additional detailed views of typical partition and column configurations. The drawing provides comprehensive architectural information including room numbers (140-159), room dimensions, floor area calculations (e.g., 1,082 SF unexcavated area), and specific construction details like closed cell foam insulation requirements and interior wall treatments. The document appears to be part of a construction or renovation project for the U.S. Army Corps of Engineers, with the file dated 10/13/2025 and created using Autodesk software.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS25RA0020009 SF 30.pdf PDF
Solicitation Amendment W912DS25RA0020008 SF 30.pdf PDF
E-512_AM 7.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
I-100.3_AM 6.pdf PDF
I-100.2_AM 6.pdf PDF
AD-101_AM 6.pdf PDF
A-304_AM 6.pdf PDF
A-315_AM 6.pdf PDF
A-503_AM 6.pdf PDF
A-003_AM 6.pdf PDF
A-002_AM 6.pdf PDF
H-103_AM 6.pdf PDF
H-104_AM 6.pdf PDF
H-102_AM 6.pdf PDF
H-001_AM 6.pdf PDF
H-108_AM 6.pdf PDF
MP-102_AM 6.pdf PDF
MH-104_AM 6.pdf PDF
M-505_AM 6.pdf PDF
S-316_AM 6.pdf PDF
S-311_AM 6.pdf PDF
S-310_AM 6.pdf PDF
S-113_AM 6.pdf PDF
S-110_AM 6.pdf PDF
S-109_AM 6.pdf PDF
S-001_AM 6.pdf PDF
Submittal Register_AM 6.pdf PDF
Appendix G_AM 5.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
A-601_AM 4.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
A-319.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C2 C3 B2 B3 B4 B5 B6 B7 B8 B9

B8.2 B9.3 B9.8

B10

B11

B11

W18

W19

W20

W21

W22

BABA

BBBB

BD BE

BF

BG

BH

CL2

A-203

C1

A-205

C1

M A

T C

H L

IN

E

A

A -1

17' - 1" 15' - 10" 13' - 11" 13' - 11" 13' - 11" 15' - 2" 15' - 6 1/2" 12' - 1" 12' - 5" 17' - 3" 12' - 7"

E1

A-301

____________ E1

A-301

C1

A-303

C1

A-303

ELEV LOBBY

CORRIDOR

WOMENS

JAN

HC SHR/TLT

MENS

144CLASSROOM

CLASSROOM

STORAGE

ELECT

IT

HALL

CLASSROOM

152 CLASSROOM

CLASSROOM

CLASSROOM

HALL

OFFICE

STORAGE

WOMENS

MENS

1,082SF ± UNEXCAVATED;

PROVIDE CLOSED CELL SRPAY

FOAM INSULATION & IGNITION

BARRIER ON UNDERSIDE OF

FLOOR ABOVE (R-12.5 MINIMUM).

142143

146147

14 A

14 A

14 A

14 A

15 A

6 A

9 A

9 A

9 A

16 A

16 A

16 A

14 A

14 A

14 A

4 A

STAIR 2

ST2

1 A

TYP

TYP

A-410

A1

A-415

A1

C1

A-304

C5

A-303

16 A 16 A

A-452

A1

B1

16 A

9 A

14 A

EXST WALLS.

2'

1/

2"

/2

7"

1"

9'

1/

2" 8'

/2

4'

1' - 3" 141' - 4 1/2"

14' - 4 1/2" 10' - 0" 14' - 4 1/2"

41' - 0"

24' - 4"

140A 140B

1/ 2"

/2

1'

1/

2"

5'

6"

STAIR 18

DF/BF12

1'

6"

7'

BL6

BL5

BL13

8 3/4"

A-510

A1

2 - 5

2 - 5

2 - 5

2 - 3 2 - 3 2 - 3 2 - 3 2 - 32 - 3

2 - 3

2 - 1A

A1

A-303

4 A

16 A

4 A

14 A

2 - 3

UP

CLASSROOM

7"9"

± 10 1/4" 28' - 3 7/8" 28' - 6 1/2" 28' - 10"

± 9"30' - 4 3/8"30' - 11"6' - 10"16' - 1 7/8"10 1/4" ± ± 8" 26' - 4"

30' - 4 3/8"

5/

8"

/4

9'

/2

/2

1/

8"

1/

8"

/2

/8

8'

7'

A-466

E6

A-465

C6

C2

A6

A2 A-465 A2C2A-466

E2

A6

2' - 2 5/8" 2' - 11 1/8" 11 3/4"A-465 A2C2

A6

A-466

C6

C2 A-466 A2

A6 A-466

C6

C2 A2

A6

2 - 7 2 - 5 2 - 72 - 5

2 - 5

(X3)

2 - 7

2 - 5

2 - 7

2 - 52 - 7

2 - 5

(X3)

2 - 5

(X3)

2 - 7

2 - 72 - 52 - 7 2 - 5

2 - 7 2 - 5

(X3) 2 - 5

2 - 5 2 - 7

2 - 7 2 - 5 2 - 72 - 5

2 - 5

(X3)

2 - 7

(X3) 2 - 5

2 - 7 2 - 5 2 - 5

2 - 7

2 - 5 2 - 7 2 - 5

2 - 5

(X2)

2 - 7 2 - 5(X4)

2 - 7

2 - 5

(X3) (X3)

(X4)

2 - 72 - 7

2 - 5

(X2)

2 - 7

2 - 5 2 - 7

A-467

G3

G7

E3

E7 A-467C7

C3

A7

A3+ 159' - 3"

+ 159' - 3"

(22) (16)(8) (36) (22) (40) (24)

(60)

(32)2 - 3

1' - 3" 17' - 8 1/2" 19' - 0" 52' - 6 1/2" 12' - 3"

2' - 2 1/2"

1 A

159A

2 - 52 - 7 2 - 5 2 - 7

2 - 52 - 52 - 7 2 - 7 2 - 5

2 - 7

2 - 72 - 5

2 - 52 - 5

2 - 7

2 - 5 2 - 7 2 - 7

2 - 5

E - 2 E - 2

(X3)

(X2)

(X2)

(X3)

BCBC

A-102

A3

TYP

A-102

A3

TYP

A-102

A1

TYP

CORNER

E - 2

2 - 1B

2 - 1A

A-206 D6

LOUVER

LOUVER LOUVER

16 A16 A

16 A

EXST UNEXCAVATED

CRAWLSPACE 188

EXST UNEXCAVATED

CRAWLSPACE

EQ

EQ

EQ

E - 2 E - 2E - 2

E - 2

(ABV)

(ABV)

9A

14A

14 A

ABOVE

1'

3"

E4

A-564

LOUVER

NORTH

LOADING DOCK CONNECTOR

EAST

EAST

(1 STORY)

WEST

SE

E

PL

AN

VA

R

IE

S;

EX

ST

E

XT

ER

IO

R W

AL

L

CLCL

2'-0" MAX @ COLUMN

1' - 9 1/2" ±

PARTITION; AS

SCHEDULED.

CONTINUE PARTITION

GWB PAST COLUMN; IF

STUD SPACING IS >2'-0",

PROVIDE 2 1/2" FRAMING.

EXISTING COLUMN.

EXISTING MASONRY

WALL.

C

LE

AR

1"

1" CLOSED CELL SPRAY

POLYURETHANE FOAM

INSULATION (R-6.3); FULL

PERIMETER OF COLUMN.

EXST EXTERIOR WALL

SEE PLAN

VARIES;

EX

ST

E

XT

ER

IO

R W

AL

L

SE

E

PL

AN

VA

R

IE

S;

EXISTING COLUMN.

EXISTING MASONRY

WALL.

1" CLOSED CELL SPRAY

POLYURETHANE FOAM

INSULATION (R-6.3); FULL

PERIMETER OF COLUMN.

PARTITION; AS

SCHEDULED.

8' -0

D O

O R

O

PE

N

IN

G S

VA

R

IE

S

(V

IF

4'

-0

W

D W

REMOVE EXST SILL AT

WDW OPEING INFILLS;

REPLACE W/ (3)

COURSES OF BRICK TO

MATCH EXST.

INFILL; PROVIDE BRICK

BACKUP AND VENEER TO

MATCH EXST.

EXST LINTEL / HEADER

TO REMAIN.

PROVIDE CMU AT

AREAWAY INFILL.

NOTE: PROVIDE WATERPROOFING

& 1/2" DRAINAGE BOARD AT BELOW

GRADE INFILL.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/13/2025 2:31:24 PM

A-102

F

IR

S T

F L

O O

R P

L A

N

W E

S T

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

E P

M

K

S M

S

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

SCALE: 1/8" = 1'-0"C1

FIRST FLOOR PLAN - WEST

SCALE: 1" = 160'-0"

KEY PLAN - WEST

KEYED NOTES-PLAN

NUMBER COMMENT

1 ALIGN FACE OF PARTITION WITH WINDOW JAMB.

2 ALIGN CENTER OF PARTITION WITH CENTER OF WINDOW MULLION OR

CENTER OF COLUMN.

3 ALIGN FACE OF PARTITION WITH FACE OF PARTITION OR COL

ENCLOSURE.

4 COLUMN ENCLOSURE TO BE PTN TYPE 1 (TYP UNO).

5 ALIGN FACE OF PARTITION WITH CORNER OF EXST WALL(S). PROVIDE

GWB CONTROL JOINT AS REQ'D.

6 EXTERIOR COLUMN ENCLOSURE TO BE PTN TYPE 16 (TYP UNO).

7 ALUM STOREFRONT WINDOW SYSTEM ABOVE.

8 PROVIDE WALL THICKNESS AND FINISH TO MATCH EXISTING. REFER

TO DETAIL B9/A-102.

9 SLAB INFILL AT REMOVAL. SEE STRUCT DWGS.

10 EXPOSED STEEL COLUMN, SEE STRUCTURAL DRAWINGS, PROVIDE

INTUMESCENT COATING ON ALL EXPOSED SURFACES. PNT 906 TYP.

11 PROVIDE GALVANIZED METAL GRATING OVER EXISTING SUBFRAME.

12 ROOF LEADER, SEE PLUMBING DWGS.

13 ELECTRICAL CONDUITS, SEE ELECTRICAL DWGS.

14 CLEAN AND REPAIR GRANITE/ LIMESTONE WALL AND SURROUND

(TYPICAL UNLESS NOTED OTHERWISE).

15 PROVIDE 1" MIN CLOSED CELL FOAM INS AT EXTERIOR WALLS (TYP).

16 PROVIDE RADIANT HEATER ENCLOSURE (SEE SECTION DETAIL).

17 PROVIDE LIMESTONE INFILL AT EXISTING OPENINGS, PATTERN TBD.

SEE D1/A-460 ELEVATION.

18 PROVIDE CLEARANCE (NO OBSTRUCTION OF ANY FIXTURE BEYOND

FINISHED SURFACES) ON BOTH SIZE OF FOLDING PARTITION.

19 PROVIDE LIMESTONE SURROUND ADDITION TO FLOOR MATCH

EXISTING.

20 PROVIDE 4’x8’x3/4” FIRE TREATED PLYWOOD COMMUNICATIONS

BACKBOARD; RUN PANELS WALL TO WALL, ORIENTED VERTICALLY,

PAINT EGGSHELL SHEEN WHITE (DO NOT PAINT OVER FIRE RATING

LABELS).

21 PROVIDE 6"H CONC CURB (HOUSE KEEPING PAD) COORD SIZE &

LOCATION WITH MEP DWGS.

23 PROVIDE 1" AIR SPACE BETWEEN PARTITIONS.

24 1" THICK CLOSED CELL SPRAY FOAM (R-6.3). PROVIDE IGNITION

BARRIER.

25 1" THICK CLOSED CELL SPRAY FOAM (R-6.3).

26 RETURN (1) LAYER 1/2" PLYWOOD & (1) 5/8" GWB TYPE X INTO

OPENING; SHIM PLUMB.

27 PROVIDE HEAD, JAMB, AND SILL RETURNS AT BASEMENT WINDOWS;

5/8" GWB OVER 1/2" PLYWOOD, SHIM PLUMB AND LEVEL.

28 PROVIDE SWITCHABLE PRIVACY GLASS.

29 PROVIDE 16 GA FLUSH, MUD IN OR INLAY ACCESS PANEL. REFER TO

FINISHES. REFER TO PLUMBING DRAWINGS.

30 REFER TO PLUMBING DRAWINGS AND SPEC FOR CLEANOUT COVER.

04 8 16268

SCALE: 1/8" = 1'-0"

CR

SCALE: 1 1/2" = 1'-0"A3

PLAN DETAIL - TYP PTN PAST COLUMN WEST

SCALE: 1 1/2" = 1'-0"A1

PLAN DETAIL - TYP CORNER COLUMN

SCALE: 1 1/2" = 1'-0"B9

SECT DET - TYP BRICK INFILL

A

D D

E N

D U

M

/2

/2

A

D D

E N

D U

M

/1

/2

File details come from the government source that posted it. Updated .