AD-101_AM 6.pdf
PDF 671 KB Posted
- Solicitation number
- W912DS25RA002
About this file
This document is an architectural First Floor Removal Plan for Building 606 at West Point, dated 10/13/2025, showing detailed demolition and modification instructions for an existing facility. The plan includes extensive removals and modifications such as sawing and removing partial height brick masonry walls, removing existing stone sills, infilling approximately 25 holes in concrete slabs from former dental chair locations, and selectively removing portions of concrete columns, walls, soffits, and exterior elements. The drawing comprehensively details room-by-room modifications across multiple spaces including lobbies, offices, exam rooms, x-ray areas, laboratories, corridors, and mechanical spaces, with precise dimensional annotations and references to structural and other related drawings for coordinated implementation of the renovation work.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
DN
UP
B11 A1 A1.3 A1.5 A1.9 A2
D1 D2 D3 D4 D5
A3 A4 A5 A6A2.7 A3.2 A3.7 A4.2 A4.4 A4.6 A5.1
W29
BA
BB
BE
BF
BG
BH
AA
AB
AC
CL1
AD
AE
DB
DA
DC
M A
T C
H L
IN
E
A
A D
-1
ELEV
STAIR 1
EXST AREAWAY
EXISTING AREAWAY
EXST
AREAWAY
AREAWAY PROVIDE
FLOOR INFILL; REFER
TO STRUCTURAL
DWGS
AREAWAY
/2
5'
1/ 2"
3'
/4
15' - 7 1/4" 10' - 4" 30' - 10" 16' - 4" 11' - 2 3/8"
6'
1/
4"
/4
/4
/4
19' - 1" 7' - 1" 8' - 3" 13' - 7" 1' - 3" 13' - 0" 8' - 5" 4' - 10" 13' - 3" 6' - 10 1/2" 6' - 4 1/2" 13' - 3" 13' - 3" 13' - 2" 1' - 7" 28' - 9"
1E9
OFFICE
1E6
OFFICE
1E8
OFFICE
1E1
VEST
1E2
CONF
1E3
LOBBY
1E4
LOBBY
1E82
RECPT
1E83
OFFICE
1E79
X-RAY
1E5
TLT
1E10
WAITING1E11
VEST
1E47
MENS
1E48
WAITING
1E49
WOMENS
1E50
JAN
1E51
CORR
1E45
OFFICE
1E36
OFFICE
1E26
OFFICE
1E25
OFFICE
1E37
X-RAY
1E44
X-RAY
1E30
EXAM AREA
1E40
EXAM AREA
1E53
OFFICE
1E41
TLT
1E32
OFFICE
1E31
OFFICE
1E29
OFFICE
1E60
EXAM RM
1E17
OFFICE
1E18
EXAM AREA
1E13
EXAM RM
1E23
EXAM RM
1E19
ELECT
1E75
OFFICE
1E74
OFFICE
1E72
OFFICE
1E81
CORR
1E54
OFFICE
1E55
LAB
1E78
X-RAY
1E76
X-RAY
1E80
STOR1E77
XRAY
1E59
EXAM RM
1E56
LAB
1E64
OFFICE
1E57
OFFICE
1E61
STOR
1E62
LAB
1E65
LAB
1E71
CONF
1E58
TLT
1E66
VEST
1E67
OFFICE
1E69
VEST
1E70
MECH
1E68
JAN
R32R32 (TYP)
R9
R6
R7
R8
R8
R2
R2
R2R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2R2
R2
R2
R2R2R2
R2
R2
R2
R2
R2
R2 R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2
R2 R2
R2
R2
R2
R32 (TYP)
R8
R1
R1
R1
R1
R31
(TYP)
R32 (TYP)
R1
R2
R1
R10
R8
R11
R11
R11
R11
R11
R11
R11
R11
R11
R11
R11
R11
R11 R8
R11
R11
R11
R1
R2
R2 R1
R1
R1
R11
R11
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1R1
R1
R32 (TYP)
R2
SA
LV
AG
E
G R
AN
IT
E
FO
R R
EI
N
ST
AL
L
; R
EM
O
VE
E
XT
W
AL
L
IN
IT
S
EN
TI
R
ET
Y
R1
R1
R12
R1
R19
EXST AREAWAY
EX
IS
TI
N
G C
O N
C C
O
LU
M N
S
AN
D B
EA
M
S
TO
R
EM
AI
N
; R
EM
O
VE
IN
FI
LL
M
AS
O
N R
Y W
AL
LS
; D O
N O
T
IM
PA
C
T 1'
7/ 8"
R1
A1
AD-301
A1
AD-301
A1
AD-302
A1
AD-302
R21 R25
R20
R20
R20 R20R24 R24
R24
R20R20R20
R20
R20
R20
R20
R20
R20
R22
R22
R22 R21
R23 R25
R21 R24
R20 R24
R23 R25
R23 R25
R23 R25
R21 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24
R22 R24 R22 R24
R22 R24R22 R24
R22 R24
R22 R24
R22 R24
R24
R22 R24R22 R24
R22 R24 R22 R24
R22 R24
R22 R24
R22 R24
R21 R24R21 R24R21 R24 R21 R24
R24 R21
R24
R22 R25
R22 R25
REMOVE SOFFIT.
R2
REMOVE SOFFIT.
REMOVE SOFFIT.
REMOVE SOFFIT.
A8
AD-310
R26
REMOVE AREAWAY COVER, INCLUDING: 19-W-4 BAR GRATING,
STL ANGLE FRAME, AND WELDED WIRE MESH SCREEN.
REMOVE EXST
STONE STEPS &
RAILING; SEE
CIVIL DWGS.
NOTE: AREA INDICATED CONTAINS HISTORIC
FINISHES & FIXTURES. LIMIT REMOVALS TO
WORK SHOWN. PROTECT ALL ADJACENT
FINISHES AND FIXTURES TO REMAIN,
INCLUDING FLOORING, WALLS, AND DOORS.
REMOVE EXISTING STONE TO
PROVIDE RECESS FOR CABINET
UNIT HEATER; COORDINATE WITH
MECHANICAL AND STRUCTURAL
DRAWINGS2' - 0" 5' - 11 3/8" 6" 2' - 6"
EXTENT OF INFILL
ADDITION; SEE
STRUCTURAL DRAWINGS
REMOVE PORTION
OF AREAWAY WALLS
/ CURB; SEE STRUCT
DRAWINGS
REMOVE EXISTING BAR
GRATING.
REMOVE EXISTING COLD FORMED METAL
FRAMING, SHEATHING, STUCCO AND
LOUVER.
/2
1/ 2"
EXISTING WINDOW
OPENING
/8
EXISTING
ASPHALT;
SEE CIVIL &
STRUCT DWGS
FOR REMOVALS
2'
1/
2"
R30
TYP
4' - 0" 9' - 4" 9' - 4" 15' - 4" 8' - 3 5/8" 15' - 4" 9' - 4" 9' - 4" 4' - 0"R13 R13 R13 R13
R30
TYP
R30
TYP
R30 TYP
AD-501
A4
AD-501
A8
AD-501
E8
AD-501
A1
REMOVE AREAWAY COVER,
INCLUDING: 19-W-4 BAR GRATING,
STL ANGLE FRAME, AND WELDED
WIRE MESH SCREEN.
AD-301
F5
EXST SIDEWALKS;
REFER TO SITE
REMOVALS DRAWINGS
EXST STAIR
EXST RETAINING
WALL
REMOVE STL
PLATE STORM
MANHOLE COVER;
REFER TO A2/A565
AND PLUMBING
DWGS.
E X
S T
S H
A F
T
R1
R20R20
R4
R1
R1
R4
R1
R20 R1
R1
R1
R1
R1
R1
R1
R4
R20 R4
R20
R4
R1R1
R1
R1
R1R20
R1
R1
R1R1
R1
R4
R3
R1
R1
R1
R1
R1 R1
R1
R20
R1
R4
R23
R23
R23
R4
R20
R4
R20
R22
R1
R4
R34
R11
R11
R37
R11
R37
R35
REMOVE PORTION OF EXST
CONC CURB @ PROPOSED
DOOR LOCATION REFER TO
A SERIES DWGS.
REMOVE
EXISTING BAR
GRATING.
BC
AD-312
A1
10' - 11 3/8"
8"
8"
SAW CUT &
REMOVE EXST
PARTIAL HT (3)
WYTHE BRICK
MASONRY WALL
REMOVE EXST
STONE SILL & (3)
WYTHE BRICK
MASONRY WALL
BELOW
12' - 5 3/4"
3' - 3
3'
CAREFULLY REMOVE
HANDRAILS &
WHEELCHAIR LIFT
SYSTEM IN THEIR
ENTIRETY
A7
AD-313
TYP
R2
FIRE ALARM PANEL
NOTE:
EXISTING FIRE ALARM
PANELS WILL BE
SALVAGED USAG WEST
POINT ELECTRIC SHOP.
DO NOT DAMAGE
PRIOR TO REMOVAL.
EXISTING FIRE ALARM
PANEL; SEE NOTE.
EXST
MASONRY
COLS
(TYP)
EXST MASONRY
COLS (TYP)
R30
TYP
R30
TYP
INFILL (25) HOLES IN EXST
CONC SLAB AT FORMER
DENTAL CHAIRS; SEE
STRUCTURAL DWGS FOR
INFILL DETAIL.
INFILL (25) HOLES IN EXST
CONC SLAB AT FORMER
DENTAL CHAIRS; SEE
STRUCTURAL DWGS FOR
INFILL DETAIL.
R5
R5
R5
NORTH
LOADING DOCK CONNECTOR
EAST
EAST
(1 STORY)
WEST
APPROXIMATE AREA OF FLOOR SLAB REMOVALS
REFER TO KEYED NOTES R9, R10, R19, AND R29.
COORDINATE WITH STRUCTURAL AND PLUMBING
DRAWINGS FOR EXTENTS.
PATCH ALL HOLES IN EXISTING CONCRETE
FLOOR SLAB PER STRUCTURAL DETAIL D1 / S-311.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt
10/13/2025 2:37:22 PM
AD-101
F
IR
S T
F L R
R E
M O
V A
L P
L A
N
E A
S T
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T
N Y
P N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
N
Y
E P
M
K
S M
S
M P
K
V N
S
E P
T E
M B
E R
W
D
S
C
Q P
K J
O B
N O
.0
ADDENDUM #6
R E
P A
IR
B
L D
G
G E
N E
R A
L I N
S T
R U
C T
IO
N
B L
D G
SCALE: 1/8" = 1'-0"A1
FIRST FLR REMOVAL PLAN - EAST 04 8 16268
SCALE: 1/8" = 1'-0"
NOTE:
SEE SHEET AD-100 FOR GENERAL
REMOVAL NOTES
KEYED NOTES - REMOVALS (CONTINUED)
# COMMENT
R16 REMOVE CONC FLOOR SYSTEM; SEE STRUCTURAL DWGS.
R17 REMOVE 5"± THICK CONCRETE HOUSEKEEPING PAD IN ITS ENTIRETY.
R19 SAWCUT EXST CONC FLOOR SLAB / ROOF DECK TO PROVIDE OPNG FOR MECH SHAFT; COORD LOCATION W/ FLOOR PLANS AND STRUCT DWGS.
R20 REMOVE FLOORING AS INDICATED ON ABATEMENT DOCUMENTS. SEE ASBESTOS ABATEMENT DRAWINGS (H SERIES).
R21 REMOVE CARPET AND ADHESIVES FROM CONCRETE FLOOR.
R22 REMOVE RESILIENT FLOORING, ADHESIVES AND MASTIC FROM CONCRETE FLOOR.
R23 REMOVE CERAMIC FLOOR TILE AND THICK SET MORTAR BED FROM CONCRETE FLOOR.
R24 REMOVE SUSPENDED CLG SYS INCL TILE, GRID, EDGE ANGLE, AND ALL ASSOCIATED HANGER WIRES IN ITS ENTIRETY.
R25 REMOVE GWB CLG ASSY INCL ALL SUPPORTING FRAMING IN ITS ENTIRETY.
R26 REMOVE EXST HAND & GUARD RAILS IN THEIR ENTIRETY. PATCH AREAS OF REMOVAL AT SUBSTRATES TO REMAIN.
R27 REMOVE PLYWOOD PANELING AND SUB FRAMING ASSEMBLY IN ITS ENTIRETY.
R28 REMOVE BRICKWORK PARTIALLY SURROUNDING EXISTING OPENING TO ALLOW FOR LIMESTONE INSTALLATION (SEE DETAILS)
R29 SAWCUT EXST CONC 5" ± THICK FLOOR SLAB AND EXCAVATE FOR UNDERSLAB PIPING AND PLUMBING TIE INS. COORDINATE EXTENTS OF EXCAVATION (LOCATION AND DEPTHS) WITH PLUMBING DRAWINGS. DO NOT UNDERMINE EXST FOUNDATIONS.
R30 REMOVE EXST WDW (TYP FOR ALL EXT WDWS). REMOVE WDW SYS IN ITS ENTIRETY INCL WD BLOCKING, SLNTS, STOOLS, & WDW TREATMENTS UNO. CLEAN / REMOVE SEALANT RESIDUALS FROM ADJ SURFACES. REFER TO BLDG ELEVATIONS & SECTIONS FOR WDW REPLACEMENT
LOCATIONS. REFER TO REMOVALS FLR PLANS FOR INTERIOR WDW REMOVALS.
R31 REMOVE WOOD / PLASTER FINISH AND FURRING FROM STRUCTURAL COLUMNS.
R32 REMOVE WOOD / PLASTER FINISH AND FURRING FROM INTERIOR SIDE OF EXTERIOR WALL.
R33 REMOVE EXST CENTER GUARDRAIL. GRIND STRINGER SMOOTH.
R34 REMOVE HIGH DENSITY STORAGE SYSTEM, INCLUDING SHELVING, FLOOR TRACKS, AND RAISED FLOORING.
R35 REMOVE RECESSED WALK OFF MATT ASSEMBLY.
R36 REMOVE SUPPLEMENTAL FRAMING INSTALLED TO SUPPORT XRAY. PRIMARY STRUCTURAL STEEL (SUPPORTING FLOOR SYSTEM) TO REMAIN.
R37 REMOVE COILING COUNTER DOOR AND ASSEMBLY IN IT'S ENTIRETY.
R38 REMOVE EXST 3" - 4" THICK CEMENT GROUT TOPPING & EXST FLOOR FINISHES. EXST CONC STRUCTURAL DECK TO REMAIN.
R39 REMOVE EXST RUBBER TREADS, RISERS, AND RESIDUAL ADHESIVES FROM EXST STAIRS.
KEYED NOTES - REMOVALS
# COMMENT
R1 REMOVE 2 1/2" TO 3 5/8" METAL STUD & 5/8" GWB
PARTITION IN ITS ENTIRETY. REMOVE LEAD LINING
AT PARTITIONS AROUND ROOMS LABELED
"X-RAY". SEE ABATEMENT NOTES DRAWING FOR
LEAD REMOVALS.
R2 REMOVE HOLLOW METAL / WOOD DOOR, FRAME,
AND HARDWARE IN ITS ENTIRETY. REMOVE LEAD
LINED WOOD DOORS AT ROOMS LABELED
"X-RAY". SEE ABATEMENT NOTES DRAWING FOR
LEAD REMOVALS.
R3 REMOVE THICK SET MORTAR (2" TO 3" THICK) AND
TILE FROM WALL.
R4 REMOVE 24" OC 2" MTL "Z" FURRING / 1 5/8" MTL
STUD & GWB SYS IN ITS ENTIRETY. REMOVE 2"
FIBERGLASS BD INSUL (TYP @ EXT WALLS).
R5 REMOVE 8" CMU PARTITION IN ITS ENTIRETY.
R5.1 REMOVE MASONRY WALL ASSEMBLY IN ITS
ENTIRETY FROM FLOOR TO STRUCTURE ABOVE.
R5.3 REMOVE 8" THICK REINFORCED CONCRETE WALL
IN ITS ENTIRETY
R6 REMOVE CONC FILLED METAL PAN STAIR SYSTEM
AND RAILINGS IN ITS ENTIRETY.
R7 REMOVE ELEVATOR SYSTEM IN ITS ENTIRETY,
INCLUDING CAB, RAILS, SUPPORTS, OPERATING /
CONTROL SYSTEM, SIGNALS, GEARS, DRIVES,
DOORS, FRAMES, AND HOISTWAYS.
R8 REMOVE ALL TOILET ROOM FIXTURES,
ACCESSORIES, AND TOILET PARTITIONS. SEE
PLUMBING DWGS FOR ADDITIONAL REMOVAL
WORK.
R9 SAWCUT EXISTING CONC FLOOR SLAB/ROOF
DECK TO PROVIDE OPENING FOR ELEVATOR
SHAFT; COORD LOCATION WITH FLOOR PLANS
AND STRUCT DWGS.
R10 SAWCUT EXISTING CONC FLOOR SLAB/ROOF
DECK TO PROVIDE OPENING FOR STAIR SHAFT;
COORD LOCATION WITH FLOOR PLANS AND
STRUCT DWGS.
R11 REMOVE CASEWORK (BASE AND WALL)
INCLUDING COUNTERTOPS.
R12 REMOVE EXTERIOR MASONRY/1'-1" THICK MIN
BRICK WALL FROM FOUNDATION UP. SEE STRUCT
DWGS.
R13 SAWCUT EXTERIOR MASONRY/STONE WALL AS
REQUIRED TO PROVIDE OPENING. SEE STRUCT
DWGS.
R14 REMOVE LOCKERS, INCLUDING 4" HIGH CONC
BASE.
R15 REMOVE RAMP ASSEMBLY IN IT'S ENTIRETY. SEE
STRUCTURAL DWGS.
NO SCALE SCALE:
KEY PLAN - EAST (EXST)
A
D D
E N
D U
M
/1
/2
| Sheets |
| AD-101 - FIRST FLR REMOVAL PLAN - EAST |
File details come from the government source that posted it. Updated .