About this file

This architectural drawing is a Second Floor Removal Plan for Building 606 at West Point, dated October 13, 2025. The plan provides a detailed layout of the existing second floor, showing room names and dimensions, with numerous areas marked for removal or modification. Key areas include multiple exam rooms, offices, a multi-purpose room, pharmacy, break room, mechanical spaces, and corridors. The drawing includes specific instructions for removing concrete toppings, waterproofing membranes, walls, and exterior elements, with careful notes about preserving existing structural components like columns and beams. Hatched areas indicate specific zones of demolition or alteration, and the plan includes a grid system and key references to other architectural drawings for comprehensive project coordination.

View the file

Other files

File Type Posted
MSEC- Building 606 - Amendment 9 - RFIs - 5 Nov 25.pdf PDF
A-601_AM 9.pdf PDF
08 71 00_AM 9.pdf PDF
MP-101_AM 7.pdf PDF
E-611_AM 7.pdf PDF
08 71 00_AM 7.pdf PDF
MSEC- Building 606 - Amendment 7 - RFIs - 21 Oct 25.pdf PDF
I-130_AM 6.pdf PDF
I-100.1_AM 6.pdf PDF
AD-301_AM 6.pdf PDF
A-305_AM 6.pdf PDF
A-102_AM 6.pdf PDF
A-413_AM 6.pdf PDF
A-502_AM 6.pdf PDF
A-504_AM 6.pdf PDF
MP-107_AM 6.pdf PDF
MP-105_AM 6.pdf PDF
MP-101_AM 6.pdf PDF
MH-101_AM 6.pdf PDF
S-322_AM 6.pdf PDF
S-315_AM 6.pdf PDF
S-107_AM 6.pdf PDF
07 52 00_AM 6.pdf PDF
08 60 45_AM 6.pdf PDF
08 81 00_AM 6.pdf PDF
I-108_AM 6.pdf PDF
A-551_AM 5.pdf PDF
MSEC- Building 606 - Amendment 5 - RFIs - 8 Oct 25 rev JF.pdf PDF
Appendix G_AM 5.pdf PDF
A-601_AM 4.pdf PDF
Solicitation Amendment W912DS25RA0020004 SF 30.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
A-319.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B11 A1 A1.3 A1.5 A1.9 A2

D1 D2 D3 D4 D5

A3 A4 A5 A6A2.7 A3.2 A3.7 A4.2 A4.4 A4.6 A5.1

W29

BA

BB

BE

BF

BG

BH

AA

AB

AC

AD

AE

DB

DA

DC

19' - 1" 7' - 1" 8' - 3" 13' - 7" 1' - 3" 13' - 0" 8' - 5" 4' - 10" 13' - 3" 6' - 10 1/2" 6' - 4 1/2" 13' - 3" 13' - 3" 13' - 2" 1' - 7" 28' - 9"

15' - 7 1/4" 10' - 4" 30' - 10" 16' - 4" 11' - 2 3/8"

1"

/4

STAIR 1

ELEV

ROOF

2E41

EXAM RM

2E42

JAN

2E43

OFFICE

2E44

EXAM RM

2E34

WAITING

2E35

CORR

2E36

STOR

2E37

XRAY RM

2E41

STOR

2E41

STOR

2E30

EXAM RM

2E29

EXAM RM

2E28

EXAM RM

2E27

EXAM RM

2E26

EXAM RM

2E25

EXAM RM

2E12

HALL

2E33

OFFICE

2E32

OFFICE

2E14

EXAM RM

2E15

EXAM RM

2E16A

MECH

2E18

TLT

2E19

LAB

2E16

LOCKERS

2E17

HALL

2E23

OFFICE

2E22

TLT

2E20

ELECT

2E21

HALL

2E24

CORR

2E6

PHARMACY

2E7

OFFICE

2E8

BREAK RM

2E9

OFFICES

2E11

CORR

2E3

CORR

2E4

TLT

2E5

JAN

2E2

MULTI PURPOSE

2E1

VEST

R9

R2

R2

R2

R1

R1

R2

R1

R2

R2

R2

R2 R2

R2

R2

R2

R2 R2 R2 R2 R2 R2

R2

R2 R2

R2

R2

R2

R2

R2

R2

R2

R2

R2R2

R2R2R2R2R2R2

R2 R2

R11

R8

R11

R11 R11

R8

R32

R6

R7

R1

R10

R1

R32 (TYP)

R32

R11

R1

R1

R1

R32

R32

R32

R1

R1

R1

R13 R13 R13 R13

R13

R32

R32

R32

R1

R1

R1

REMOVE CONC TOPPING

PER STRUCT DWGS;

REMOVE WATERPROOFING

MEMBRANE FROM

HORIZONTAL SURFACES.

REMOVE WALL TO

BELOW FLOOR LEVEL,

SEE STRUCT DWGS.

/SEE A1 AD-110

R19

2'

4"

EX

IS

TI

N

G C

O

NC

C O

LU

M

N S

AN

D

B

EA

M S

TO

R

EM

AI

N

; R

EM

O

VE

IN

FI

LL

M

AS

O

N R

Y W

AL

LS

, D O

N O

T

IM

PA

C

T

R12

R12

A1

AD-301

A1

AD-301

A1

AD-302

A1

AD-302

M A

T C

H L

IN

E

A

A D

-1

/2

1/ 2"

/2

1/ 2"

3'

/4

R20 R24 R20 R24

R20 R25

R20 R25

R20 R24

R20 R25R20 R25 R20 R24

R20 R24R20 R24

R20

R20 R24R20 R24

R20 R24R20 R24R20 R24R20 R24R20 R24R20 R24

R20 R24 R20 R24

R20 R24

R20

R20 R25 R20 R24

R20 R24

R20 R24

R20 R24

R20 R24

R20 R24

R23 R25

R8 R23 R25

R20 R24

R22 R24

R22 R24

R22 R24

R22 R24

R20 R24

R13

R27 R27 R27

R27 R27

R28 R28

R28 R28 R28 R28

R30 TYP

R30 TYP

R30 TYP

R30 TYP

R30

TYP

1/

2"

AD-501

E4

AD-501

E1

R30

TYP

R30

TYP

AD-301

F5

E X

S T

S H

A F

T

R23

R20

R20

R20

R1

EXST STEEL BEAM

OVERHEAD TO REMAIN

R17

R36

R36

EXST LEE / RIDGEWAY RAMP

1/4"1' - 11 1/2"

SA

LV

AG

E

G R

AN

IT

E

FO

R R

EI

N

ST

AL

L

; R

EM

O

VE

E

XT

W

AL

L

IN

IT

S

EN

TI

R

ET

Y

1/ 2"

3'

1"

BC

A4

AD-311

R20

R27

CERAMIC TILE FLOORING ASSUMED

TO BE THICK MUD SET IN HALL 2E12

R20

CERAMIC TILE FLOORING ASSUMED

TO BE THICK MUD SET IN HALL 2E12

R5

R5

R5 6

NORTH

LOADING DOCK CONNECTOR

EAST

EAST

(1 STORY)

WEST

APPROXIMATE AREA OF FLOOR SLAB REMOVALS

REFER TO KEYED NOTES R9, R10, R19, AND R29.

COORDINATE WITH STRUCTURAL AND PLUMBING

DRAWINGS FOR EXTENTS.

PATCH ALL HOLES IN EXISTING CONCRETE

FLOOR SLAB PER STRUCTURAL DETAIL D1 / S-311.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/13/2025 2:33:39 PM

AD-103

S E

C O

N D

F L

R R

E M

O V

A L

P L A

N

E A

S T

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

E P

M

K

S M

S

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

SCALE: 1/8" = 1'-0"A1

SECOND FLR REMOVAL PLAN - EAST

04 8 16268

SCALE: 1/8" = 1'-0"

NOTE:

SEE SHEET AD-100 FOR GENERAL

REMOVAL NOTES

KEYED NOTES - REMOVALS (CONTINUED)

# COMMENT

R16 REMOVE CONC FLOOR SYSTEM; SEE STRUCTURAL DWGS.

R17 REMOVE 5"± THICK CONCRETE HOUSEKEEPING PAD IN ITS ENTIRETY.

R19 SAWCUT EXST CONC FLOOR SLAB / ROOF DECK TO PROVIDE OPNG FOR MECH SHAFT; COORD LOCATION W/ FLOOR PLANS AND STRUCT DWGS.

R20 REMOVE FLOORING AS INDICATED ON ABATEMENT DOCUMENTS. SEE ASBESTOS ABATEMENT DRAWINGS (H SERIES).

R21 REMOVE CARPET AND ADHESIVES FROM CONCRETE FLOOR.

R22 REMOVE RESILIENT FLOORING, ADHESIVES AND MASTIC FROM CONCRETE FLOOR.

R23 REMOVE CERAMIC FLOOR TILE AND THICK SET MORTAR BED FROM CONCRETE FLOOR.

R24 REMOVE SUSPENDED CLG SYS INCL TILE, GRID, EDGE ANGLE, AND ALL ASSOCIATED HANGER WIRES IN ITS ENTIRETY.

R25 REMOVE GWB CLG ASSY INCL ALL SUPPORTING FRAMING IN ITS ENTIRETY.

R26 REMOVE EXST HAND & GUARD RAILS IN THEIR ENTIRETY. PATCH AREAS OF REMOVAL AT SUBSTRATES TO REMAIN.

R27 REMOVE PLYWOOD PANELING AND SUB FRAMING ASSEMBLY IN ITS ENTIRETY.

R28 REMOVE BRICKWORK PARTIALLY SURROUNDING EXISTING OPENING TO ALLOW FOR LIMESTONE INSTALLATION (SEE DETAILS)

R29 SAWCUT EXST CONC 5" ± THICK FLOOR SLAB AND EXCAVATE FOR UNDERSLAB PIPING AND PLUMBING TIE INS. COORDINATE EXTENTS OF EXCAVATION (LOCATION AND DEPTHS) WITH PLUMBING DRAWINGS. DO NOT UNDERMINE EXST FOUNDATIONS.

R30 REMOVE EXST WDW (TYP FOR ALL EXT WDWS). REMOVE WDW SYS IN ITS ENTIRETY INCL WD BLOCKING, SLNTS, STOOLS, & WDW TREATMENTS UNO. CLEAN / REMOVE SEALANT RESIDUALS FROM ADJ SURFACES. REFER TO BLDG ELEVATIONS & SECTIONS FOR WDW REPLACEMENT

LOCATIONS. REFER TO REMOVALS FLR PLANS FOR INTERIOR WDW REMOVALS.

R31 REMOVE WOOD / PLASTER FINISH AND FURRING FROM STRUCTURAL COLUMNS.

R32 REMOVE WOOD / PLASTER FINISH AND FURRING FROM INTERIOR SIDE OF EXTERIOR WALL.

R33 REMOVE EXST CENTER GUARDRAIL. GRIND STRINGER SMOOTH.

R34 REMOVE HIGH DENSITY STORAGE SYSTEM, INCLUDING SHELVING, FLOOR TRACKS, AND RAISED FLOORING.

R35 REMOVE RECESSED WALK OFF MATT ASSEMBLY.

R36 REMOVE SUPPLEMENTAL FRAMING INSTALLED TO SUPPORT XRAY. PRIMARY STRUCTURAL STEEL (SUPPORTING FLOOR SYSTEM) TO REMAIN.

R37 REMOVE COILING COUNTER DOOR AND ASSEMBLY IN IT'S ENTIRETY.

R38 REMOVE EXST 3" - 4" THICK CEMENT GROUT TOPPING & EXST FLOOR FINISHES. EXST CONC STRUCTURAL DECK TO REMAIN.

R39 REMOVE EXST RUBBER TREADS, RISERS, AND RESIDUAL ADHESIVES FROM EXST STAIRS.

KEYED NOTES - REMOVALS

# COMMENT

R1 REMOVE 2 1/2" TO 3 5/8" METAL STUD & 5/8" GWB

PARTITION IN ITS ENTIRETY. REMOVE LEAD LINING

AT PARTITIONS AROUND ROOMS LABELED

"X-RAY". SEE ABATEMENT NOTES DRAWING FOR

LEAD REMOVALS.

R2 REMOVE HOLLOW METAL / WOOD DOOR, FRAME,

AND HARDWARE IN ITS ENTIRETY. REMOVE LEAD

LINED WOOD DOORS AT ROOMS LABELED

"X-RAY". SEE ABATEMENT NOTES DRAWING FOR

LEAD REMOVALS.

R3 REMOVE THICK SET MORTAR (2" TO 3" THICK) AND

TILE FROM WALL.

R4 REMOVE 24" OC 2" MTL "Z" FURRING / 1 5/8" MTL

STUD & GWB SYS IN ITS ENTIRETY. REMOVE 2"

FIBERGLASS BD INSUL (TYP @ EXT WALLS).

R5 REMOVE 8" CMU PARTITION IN ITS ENTIRETY.

R5.1 REMOVE MASONRY WALL ASSEMBLY IN ITS

ENTIRETY FROM FLOOR TO STRUCTURE ABOVE.

R5.3 REMOVE 8" THICK REINFORCED CONCRETE WALL

IN ITS ENTIRETY

R6 REMOVE CONC FILLED METAL PAN STAIR SYSTEM

AND RAILINGS IN ITS ENTIRETY.

R7 REMOVE ELEVATOR SYSTEM IN ITS ENTIRETY,

INCLUDING CAB, RAILS, SUPPORTS, OPERATING /

CONTROL SYSTEM, SIGNALS, GEARS, DRIVES,

DOORS, FRAMES, AND HOISTWAYS.

R8 REMOVE ALL TOILET ROOM FIXTURES,

ACCESSORIES, AND TOILET PARTITIONS. SEE

PLUMBING DWGS FOR ADDITIONAL REMOVAL

WORK.

R9 SAWCUT EXISTING CONC FLOOR SLAB/ROOF

DECK TO PROVIDE OPENING FOR ELEVATOR

SHAFT; COORD LOCATION WITH FLOOR PLANS

AND STRUCT DWGS.

R10 SAWCUT EXISTING CONC FLOOR SLAB/ROOF

DECK TO PROVIDE OPENING FOR STAIR SHAFT;

COORD LOCATION WITH FLOOR PLANS AND

STRUCT DWGS.

R11 REMOVE CASEWORK (BASE AND WALL)

INCLUDING COUNTERTOPS.

R12 REMOVE EXTERIOR MASONRY/1'-1" THICK MIN

BRICK WALL FROM FOUNDATION UP. SEE STRUCT

DWGS.

R13 SAWCUT EXTERIOR MASONRY/STONE WALL AS

REQUIRED TO PROVIDE OPENING. SEE STRUCT

DWGS.

R14 REMOVE LOCKERS, INCLUDING 4" HIGH CONC

BASE.

R15 REMOVE RAMP ASSEMBLY IN IT'S ENTIRETY. SEE

STRUCTURAL DWGS.

SCALE: 1" = 160'-0"

KEY PLAN - EAST (EXST)

A

D D

E N

D U

M

/1

/2