08 71 00_AM 7.pdf
PDF 203 KB Posted
- Solicitation number
- W912DS25RA002
About this file
This document is a detailed Door Hardware specification (Section 08 71 00) for repairing Building 606, a General Instruction Building located at the United States Military Academy (USMA) at West Point, New York. The specification comprehensively outlines door hardware requirements, including hinges, locks, exit devices, closers, strikes, cylinders, and other associated components for both exterior and interior doors. The document provides extensive hardware schedules for 75 different hardware sets, specifying precise hardware configurations for various door types such as classroom doors, stair enclosures, electrical rooms, storage spaces, and specialized areas like secure lab and fire pump rooms.
The specification mandates strict adherence to multiple industry standards from organizations like BHMA (Builders Hardware Manufacturers Association), ASTM, NFPA, and ADA, with specific requirements for material finishes, security grades, and functional performance. Each hardware set includes detailed "Theory of Operation" descriptions, outlining how doors should function in terms of access control, locking mechanisms, and emergency egress. The hardware is predominantly specified with BHMA 630 (satin stainless steel) and 689 (aluminum paint) finishes, and includes advanced features like electromechanical locks, access control compatibility, electromagnetic door holders, and specialized security mechanisms for different operational environments within the building.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPAIR BUILDING 606, GENERAL INSTRUCTION BUILDING W912DS19C0034
USMA, WEST POINT, NY PN 94078
SECTION 08 71 00
DOOR HARDWARE
02/16, CHG 4: 02/22
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2021) Butts and Hinges
ANSI/BHMA A156.3 (2020) Exit Devices
ANSI/BHMA A156.4 (2013) Door Controls - Closers
ANSI/BHMA A156.5 (2020) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2021) Architectural Door Trim
ANSI/BHMA A156.7 (2016) Template Hinge Dimensions
ANSI/BHMA A156.8 (2021) Door Controls - Overhead Stops and Holders
ANSI/BHMA A156.10 (2017) Power Operated Pedestrian Doors
ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.14 (2013) Sliding and Folding Door Hardware
ANSI/BHMA A156.15 (2021) Release Devices Closer Holder, Electromagnetic and Electromechanical
ANSI/BHMA A156.16 (2018) Auxiliary Hardware
ANSI/BHMA A156.18 (2020) Materials and Finishes
ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors
ANSI/BHMA A156.21 (2019) Thresholds
ANSI/BHMA A156.22 (2021) Gasketing
SECTION 08 71 00 Page 1
ANSI/BHMA A156.25 (2013) Electrified Locking Devices
ANSI/BHMA A156.26 (2012) Continuous Hinges
ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators
ANSI/BHMA A156.36 (2010) Auxiliary Locks
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2023; ERTA 4 2023) National Electrical Code
NFPA 72 (2022) National Fire Alarm and Signaling Code
NFPA 80 (2022) Standard for Fire Doors and Other Opening Protectives
NFPA 101 (2021; TIA 21-1) Life Safety Code
NFPA 252 (2022) Standard Methods of Fire Tests of Door Assemblies
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2017) Specifications for Standard Steel Doors and Frames
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (updated continuously online) Building Materials Directory
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Manufacturer's Detail Drawings; G , AE
Verification of Existing Conditions; G, AE
Hardware Schedule; G, AE
SECTION 08 71 00 Page 2
Keying; G, AE
SD-03 Product Data
Hardware Items; G, AE
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1; G, AE
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions.
1.4 PRODUCT DATA
Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Provide Hardware Item List and Hardware Schedule containing the following information, and additional information as needed to identify the complete make up of each hardware set and its application to each opening:
1.5.1 Hardware Item List:
a. Hardware Type
b. Item Number
c. Quantity
d. Size(s)
e. Reference Publication / Type Number
f. Manufacturer's Name / Catalog Number
g. Key Control Symbols
h. UL Mark (If fire rated and listed)
i. BHMA Finish(es)
j. Remarks
1.5.2 Hardware Schedule
a. Hardware Set Number
SECTION 08 71 00 Page 3
b. Opening Number(s)
c. Opening Description (single/double leaf, hand, size, door/frame material)
d. Fire Rating
e. Sound Rating
f. Hardware Items
g. Quantity
h. Size
i. BHMA Finish
j. Remarks
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING
Keying will be performed by the installation key shop. Deliver cores and key blanks as directed by the Contracting Officer.
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and
SECTION 08 71 00 Page 4 all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in SECTION 28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS).
2.3.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.
2.3.2 Continuous Hinges
Where continuous hinges are required, provide in accordance with
ANSI/BHMA A156.26 .
2.3.3 Locks and Latches
a. At exterior locations provide locksets of full stainless steel type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.
b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.
2.3.3.1 Mortise Locks and Latches
Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide levers and roses of mortise locks with screwless shanks and no exposed screws.
2.3.3.2 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.3.3.3 Combination (Cipher) Locks
Heavy-duty, mechanical combination lockset with five push buttons, standard sized knobs, 3/4 inch deadlocking latch, 2-3/4 inch backset.
Locks to operate by pressing two or more of the buttons in unison or individually in the proper sequence. Inside knob operates the latch.
Provide a keyed cylinder on the interior to permit setting the combination.
Provide a keyed removable core cylinder on the exterior to permit bypassing the combination.
SECTION 08 71 00 Page 5
2.3.4 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch.
Use stainless steel or bronze base metal with plated finishes. Also include stainless steel fasteners and screws.
2.3.5 Cylinders and Cores
Provide cylinders and cores for new locks, including locks provided under other sections of this specification by Best, Dormakaba Group6161 East 75th Street, Indianapolis, IN 46250 USA 855-365-2407.. Provide cylinders and cores with seven pin tumblers. Provide Best 1C7 small format interchangeable type cylinders and cores. Provide cores (SFIC) that are removable by special control keys. Sole Source - no other suppliers or source will satisfy project requirements as implemented by FAR 6.302 - 1 (c). Stamp each interchangeable core with a key control symbol in a concealed place on the core.
2.3.6 Push Button Mechanisms
Provide in accordance with ANSI/BHMA A156.5 , Grade 1.
2.3.7 Electrified Hardware
Comply with the requirements of NFPA 70 for wiring of electrified hardware.
2.3.7.1 Electric Strikes and Frame Mounted Actuators
Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.
Provide electric strikes that remain secure during power failure. Provide a separate power supply for electric strikes, other locking devices and ancillary parts. Provide strikes and actuators with a minimum opening force of 2300 pounds. Configure strikes to match latching configuration of latching hardware.
Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from reverse current surges.
2.3.7.1.1 Solenoid
Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.
SECTION 08 71 00 Page 6
2.3.7.1.2 Signal Switches
Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.
Signal switches must report a forced entry to the system.
2.3.7.1.3 Tamper Resistance
Provide strike guards that prevent tampering with the latch bolt of the locking hardware or the latch bolt keeper of the electric strike. Strike guards to bolt through the door using tamper resistant screws. Provide strike guards made of 1/8 inch thick brass and that are 11-1/14 inch high by 1-5/8 inch wide, with a minimum 5/32 inch wide offset.
2.3.7.1.4 Coordination
Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.
2.3.7.1.5 Mounting Method
Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.
2.3.7.2 Electrified Mortise Locks
Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.
Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.
Provide hardware from the same manufacturer as specified for mechanical locks with the same keying, lever and trim designs.
Function: Lock is electronically unlocked (fail secure). Door is always operable from the exterior side of opening based on locking function.
2.3.7.2.1 High Security Pedestrian door lock with electromechanical combination lock.
Pedestrian door preassembled high security lock which includes an integrated electromechanical lock (FF-L-2740), and provides single motion egress and includes interior and exteriror handle levers, electronic release capability for access control via card reader by security vendor, and key bypass. The lock shall be fail secure and meet the requirements of FF-L-2890C (Type II).
2.3.7.2.2 Power Transfer Hinges
Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.
SECTION 08 71 00 Page 7
2.3.7.3 Auxiliary electrified door hardware
Door Contacts: Provide devices to be embedded in doors that are connected to security system to report door status. Coordinate with building access control system.
2.3.7.4 Card Readers and Keypad Access Control Hardware
Coordinate access control hardware with corresponding devices and systems specified in SECTION 28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS).
2.3.7.5 Sole Source Requirement
Provide Hirsh access control system, including Mx controllers, Velocity software, TS readers and compatible secure keypads. Sole source - no other suppliers or source will satisfy project requirements as implemented by FAR 6.302-1(c).
2.3.7.6 Power Operated Pedestrian Door Hardware
Provide in accordance with ANSI/BHMA A156.10 , Grade 1.
2.3.7.7 Release Devices
In accordance with ANSI/BHMA A156.15 , Grade 1.
2.3.7.7.1 Release Devices
Provide wall mounted Electromagnetic release devices connected to fire alarm system.
2.3.7.8 Power Assist and Low Energy Power Operated Doors
Provide in accordance with ANSI/BHMA A156.19 , Grade 1.
2.3.8 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
2.3.8.1 Lever Handles
Provide lever handles . Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
2.3.9 Keys
Furnish seven change keys for each interchangeable core, furnish two control keys, six maters keys, and six construction master keys. Furnish a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S.
property - do not duplicate." Do not place room numbers on keys.
SECTION 08 71 00 Page 8
2.3.10 Door Bolts
Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.
2.3.11 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
Use stainless steel inside bracketed or door mounted closers on exterior doors. Non-ferrous closers, such as aluminum or cast bronze, are permissible where door utilization is minimal. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.
2.3.11.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.3.12 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.3.13 Electromagnetic Stops and Holders
2.3.13.1 Electromagnetic Door Holders
BHMA A156.15, Grade 1; wall-mounted electromagnetic single unit with strike plate attached to swinging door; coordinate with electrical trade, fire detectors and interface with fire-alarm system for labeled fire-rated door assemblies.
a. Magnet Projection: 1 inch (25 mm).
b. Armature Projection: 1-5/8 inches (41 mm).
2.3.14 Overhead Stops
Overhead stop ANSI/BHMA A156.8.
2.3.15 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.3.15.1 Sizes of Armor Mop and Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors. Provide
SECTION 08 71 00 Page 9
6 inch mop plates.
a. Material: Fabricated from 0.050 inch thick stainless steel with manufacturer's standard machine or self-tapping screw fasteners.
2.3.16 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.3.17 Door Gasketing
BHMA A156.22; with resilient or flexible seal strips that are easily replaceable and readily available from stocks maintained by manufacturer.
a. Maximum Air Leakage: When tested according to ASTM E283 with tested pressure differential of 0.3-inch wg (75 Pa), as follows:
1. Smoke-Rated Gasketing: 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) of door opening.
2. Gasketing on Single Doors: 0.3 cfm/sq. ft. (3 cu. m per minute/sq.
m) of door opening.
2.3.18 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.
2.3.18.1 Sound Proofing
Door Bottoms:
a. Full-Mortise, Automatic
b. Low closing force mechanism that actuates a drop-down bar when the door is closed.
c. EPDM seal.
d. Reversible.
2.3.19 Soundproofing Gasketing.
Provide in accordance with ANSI/BHMA A156.22. Provide adjustable doorstops at heads, jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in HARDWARE SETS Paragraph.
2.3.20 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
SECTION 08 71 00 Page 10
Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed
0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.3.20.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.
2.3.20.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.3.20.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.3.21 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, factory painted finish.
Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Set drips in sealant and fasten with stainless steel screws.
2.3.21.1 Door Rain Drips
Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.
2.3.21.2 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.
2.3.22 Auxiliary Hardware (Other than locks)
Provide in accordance with ANSI/BHMA A156.16 , Grade 1.
2.3.23 Aluminum Sliding Door Hardware
Sliding Door Hardware: BHMA A156.14; consisting of complete sets including rails, hangers, supports, rollers, stops, floor guides, and accessories indicated.
a. Overhead Track Hardware: Extruded alloy aluminum 6063-T6 pre-fabricated in straight configuration for supporting door panels hung from Roller Assemblies.
b. Mounting Type: Face Mount. I-shaped track assembly as required to support a minimum door panel load of 275 lbs (125 kg).
c. Extruded aluminum with Clear Anodized finish Conforming to AA-M12C22A4, Class I and AAMA 611.
d. Roller Assembly: Nylon encapsulated ball bearing rollers provide
SECTION 08 71 00 Page 11 smooth, silent movement of door panels. Two (2) soft-close rollers assemblies minimum per panel.
e. Carrying capacity: 200 lbs (91 kg) minimum (single panel).
f. Height adjustment: ¼ inch (6 mm) minimum.
g. Locks and Trim: Manufacturer's standard as required to interface with mechanical cipher locking mechanism.
h. Adjust stops to allow minimum 1-1/2 inch clear between pulls and jambs.
i. Accessories: Hidden Door Guide concealed in groove at bottom of door.
Provide in accordance with ANSI/BHMA A156.14 , Grade 1. Finishes to match other hardware specified herein.
2.3.24 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
2.5 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish . Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.
Match hardware finish for aluminum doors to match the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 , Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core
SECTION 08 71 00 Page 12 construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Stop Applied Weatherstripping
Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.1.2 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.3 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
3.1.2 Fire and Smoke Doors and Frames
Install fire doors and smoke door gasketing in accordance with BHMA A156.22 and NFPA 105.
a. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.
1) Do not notch perimeter gasketing to install other surface-applied hardware.
b. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.
c. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.
3.1.3 Soundproofing Installation
Install according to manufacturer's written instructions.
3.1.4 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with stainless steel countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.
3.2 FIRE DOORS AND EXIT DOORS
Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door
SECTION 08 71 00 Page 13 assemblies.
3.3 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
SECTION 08 71 00 Page 14
3.6 DOOR HARDWARE SCHEDULE
EXTERIOR DOOR HARDWARE SCHEDULE
Hardware Set #001 Exterior Stair Exit Flood Doors B12B and 151 Qty BHMA/ANSI Government Description BHMA Finish
A156.26 Continuous Geared Aluminum Hinges Supplied by Flood Door Manufacturer
689 Match Door
1 A156.3 Rim Exit Device - storeroom function 630
1 A156.6 Lever Trim 630
1 A156.4 Surface Closer - push side 689
1 A156.5 Cylinder 630
1 A156.16 Wall Stop 630
A156.21 Threshold: supplied by Flood Door Manufacturer
Mill Finish
A156.22 Door Seals: (jamb/head/sill)Supplied by Flood Door Manufacturer
Black
Note: All door hardware for flood doors shall be approved by door manufacturer as part of manufacturer's engineering review process to certify the necessary flood resistance performance of the door assemblies.
Hardware Set #002 Exterior Areaway Access Paired Flood Door B13 Qty BHMA/ANSI Government Description BHMA Finish
A156.26 Continuous Geared Aluminum Hinges Supplied by Flood Door Manufacturer
689 Match Door
2 A156.13 Mortise Lockset - storeroom function (locked both sides)
2 A156.4 Surface Closer - push side 689
1 A156.16 Wall Stop - RHR Leaf 630
A156.16 Removeable Center Mullion - Supplied by Flood Door Manufacturer
SECTION 08 71 00 Page 15
A156.21 Threshold: supplied by Flood Door Manufacturer Mill Finish
A156.22 Door Seals: (jamb/head/sill)Supplied by Flood Door Manufacturer
Black
Theory of Operation: Active leaf locked from interior and exterior side.
Active leaf can be unlocked from interior or exterior by key. Inactive leaf can be unlocked by unlatching flushbolts.
Note: All door hardware for flood doors shall be approved by door manufacturer as part of manufacturer's engineering review process to certify the necessary flood resistance performance of the door assemblies.
Hardware Set #003 Exterior Automatic Sliding Entry Doors 100A,134A and 229A
Qty BHMA/ANSI Government Description BHMA Finish
1 A156.10 Cylinder 630
Emergency Exit devices (Provided by Door Manufacturer)
Emergency Closers (provided by Door Manufacturer)
689 Match Door
Threshold: (floor-mounted guide) provided by Door Manufacturer
Mill Finish
Theory of Operation: Door opens from exterior by use of motion sensor device as provided by door manufacture. Egress from interior is activated by motion sensor device as provided by door manufacturer. Exit devices operate emergency breakout function when power is out. Keyed cylinder resets unit to normal operation after emergency exit function has been activated.
Hardware Set #004 Existing Exterior Exit Stair Doors 107B,254C and 344B
Qty BHMA/ANSI Government Description BHMA Finish
1 A156.26
Remove existing hinges, exit device, patch holes operational trim, cylinder, closer, weatherstripping and threshold - patch holes Replace existing hinges with:
Continuous Geared Aluminum Hinges
Patch holes
689 Match Door
1 A156.3 Replace existing exit device and trim with:
Rim Exit Device - storeroom function with lever handle trim
SECTION 08 71 00 Page 16
1 A156.5 Replace existing cylinder with:
Cylinder
2 A156.4 Replace existing closer with:
Surface Closer (push side mounting) 689 Match Door
1 A156.22 Replace existing weatherstripping with:
Weatherstripping (jamb/head/sill) Black
1 A156.21 Replace existing threshold with:
Threshold Mill Finish
Hardware Set #005 Exterior Exit Doors at Loading Door 240A Qty BHMA/ANSI Government Description BHMA Finish
A156.26 Continuous Geared Aluminum Hinges 689 Match Door
1 A156.13 Mortised Lockset - storeroom function
Door always unlocked from roof side
1 A156.4 Surface Closer - push side 689
1 156.16 Wall Stop 630
1 A156.21 Threshold Mill Finish
1 A156.22 Weatherstripping (jamb/head/sill) Black
Hardware Set #006 Exterior Aluminum Door 510A
Qty BHMA/ANSI Government Description BHMA Finish
Continuous Geared Aluminum Hinges (by Door Manufacturer)
1 A156.13 Mortised Lockset - storeroom function 630
1 156.4 Surface Closer (pull side mounting) 689 Match Door
Weatherstripping (jamb/head/sill)(by door manufacturer)
SECTION 08 71 00 Page 17
Threshold (By door manufacturer) Mill Finish
Hardware Set #007 Exterior Aluminum Door 510B Qty BHMA/ANSI Government Description BHMA Finish
A156.26 Continuous Geared Aluminum Hinges (Supplied by Flood Door Manufacturer)
689 Match Door
1 A156.13 Mortised Lockset - storeroom function 630
1 A156.4 Surface Closer (pull side mounting) 689 Match Door
156.22 Weatherstripping (jamb/head/sill)(by flood
door manufacturer)
A156.21 Threshold (By door manufacturer)
1 A156.16 Wall Stop 630
INTERIOR DOOR HARDWARE SCHEDULE
Hardware Set #008 Interior Stair Exit Doors B01,107A,211,310 and 401
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.3 Rim Exit Device - Passage function 630
1 A156.6 Lever Trim 630
1 156.4 Surface Closer - pull side 689
1 A156.16 Wall Stop 630
Hardware Set #009 Interior Classroom Doors B02, B03, 120, 124, 125, 127, 129, 133, 145, 152, 153, 154, 155, 309, 334, 335, 350, 351, 352, 438, 439, 454 and 456
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
SECTION 08 71 00 Page 18
1 A156.13 Mechanical Push-Button Mortise Lockset -classroom function
1 156.4 Surface Closer (pull side mounting) 689 Match Door
1 A156.16 Wall Stop 630
Theory of Operation: Active leaf always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #010 Interior Toilet Doors B05, B07, 128, 136, 137, 143, 219, 320, 321, 506 and 508
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - privacy function Occupancy Indicator ("vacant" "in-use")
1 A156.5 Kick plate - push side 689
1 A156.5 Mop Plate - Pull side 689
1 A156.16 Wall Stop 630
Hardware Set #011 Interior Janitor, Storage, Crawl Space Doors B06, B11B, B15, 142, 159A, 345, 415, 449, 507, and 527)
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function 630
Hardware Set #012 Interior IT Doors B08, B09, B10, 150, 212, 249, 349, 416, 453 and 531
SECTION 08 71 00 Page 19
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.3 Mortise Exit Device - storeroom function 630
1 A156.31 Electric Strike 652
1 A156.4 Surface Closer with stop function - push side 689
1 A156.29 Access control Hardware (See Section 28 10 05) Door Contacts
Theory of Operation: Door is always open from the interior by use of exit device and locked from exterior. Door is unlocked from exterior by use of keyed cylinder. Electric strike is released by card reader device (See Section 28 10 05). Door is automatically relocked upon closing. Door is fail secure. Door status reported by card reader security system.
Coordinate with building access control system.
Hardware Set #013 Interior Break Room Door
B11A
Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset classroom function - Active Leaf. (RH)
1 A156.16 Flush Bolts - Inactive Leaf 630
2 A156.4 Surface Closer (pull side mounting) 689 Match Door
1 A156.16 Wall Stop - RH Leaf 630
Theory of Operation: Active leaf always open from interior side and locked from exterior. Inactive leaves locked and unlocked manually using flush bolts. Active leaf is unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing if inactive leaf is manually locked first. Door is fail secure.
Hardware Set #014 Interior Corridor Paired Doors B12A Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 630
SECTION 08 71 00 Page 20
2 A156.6 Push/Pull Operating hardware:3" by 12" by 0.062" thick rounded Corner Push Plate and 1" diameter, 8" offset pull
2 A156.4 Surface Closer - pull side 689
2 A156.16 Wall Stops 630
Hardware Set #015 Interior Electrical Room Doors B14A,114, 149,220 and 322
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.3 Rim Exit Device - storage function 630
1 A156.6 Lever Trim 630
1 A156.4 Surface Closer with stop function - push side 689
Hardware Set #016 Interior Electrical Room Paired Doors B14B Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 689 Match Door
1 A156.3 Rim Exit Device - storeroom function Active Leaf RHR.
1 A156.16 Automatic Flush Bolts - Inactive Leaf 626
2 A156.4 Surface Closer (push side mounting) 689 Match Door
1 A156.3 Coordinator 630
Active leaf is aways open from interior and locked from exterior. When the active leaf is opened, the automatic flush bolt retracts, allowing the inactive leaf to open. When the active leaf is open, the coordinator prevents it from closing until the inactive door bypasses. The inactive door closing causes the strike plate on the top of the door to contract the cam and lift arm, allowing the active door to close.
Hardware Set #017 Interior Mechanical Storage Room Paired Doors B16A, 131, 132, 139B ,205 and 205A
Qty BHMA/ANSI Government Description BHMA Finish
SECTION 08 71 00 Page 21
6 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function
- Active Leaf RHR.
1 A156.16 Flush Bolts - Inactive Leaf 630
Hardware Set #018 Interior Mechanical Room Paired Doors B16B Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function - Active leaf
1 A156.16 Flush Bolts - Inactive Leaf 630
2 A156.16 Wall Stop RHR Leaf 630
SECTION 08 71 00 Page 22
Hardware Set #019 Interior Aluminum Paired Vestibule Door 100B Qty BHMA/ANSI Government Description
FORCED ENTRY RESISTANT
BHMA Finish
1 A156.26 Continuous Geared Hinge (by Door Manufacturer)
Offset push/pulls (By door manufacturer)
2 A156.19 swing door operator 628
2 A156.3 Concealed Vertical Rod Exit devices 628
1 A156.19 Battery backup unit
1 A156.19 motion sensor - interior side
2 presence detection sensors
2 A156.19 Finger trap protection device
Theory of Operation: Doors opens from exterior by use of card reader device (See section 28 10 05). Egress from interior is activated by motion sensor device as provided by door manufacturer. Door status reported by card reader security system. Coordinate with building access control system. Exit devices operate emergency breakout function when power is out.
Hardware Set #020 Existing Interior Classroom Doors 102 and 105 Qty BHMA/ANSI Government Description BHMA Finish
1 A156.13 Replace existing lockset with:
Mortise Lockset classroom function
Patch Holes
3 A156.1 Remove existing butt hinges Replace existing butt hinges with:
Butt Hinges - verify existing size 630
1 A156.4 Surface Closer (push side mounting) All other existing hardware to remain.
689 Match Door
Hardware Set #021 Existing Interior Vestibule Door 103
SECTION 08 71 00 Page 23
Remove existing hold opens, patch holes in door, masonry. Remove existing floor/ceiling pivots. Remove existing push plates, patch holes in door. Remove existing kick plates, patch holes in door. Remove existing closers, patch holes in door and trim
Qty BHMA/ANSI Government Description BHMA Finish
4 A156.17 Recessed offset floor/ceiling pivots 613
1 A156.3 Exit device flat trim 613
1 A156.3 Surface vertical rod exit device - classroom function
1 A156.3 Surface vertical rod exit device with electrified latch retraction, classroom function
1 A156.6 Operating trim: pull 613
1 A156.6 Operating trim: flat 613
1 A156.5 Mortise cylinder 613
2 A156.4 Surface Closers, push side 690
1 A156.36 Power Transfer
1 A156.36 Door Position Switch
1 A156.16 Kick Plates 613
1 A156.36 Card Reader
Hardware Set #022 Existing Exterior Entry Door 104
SECTION 08 71 00 Page 24
Remove existing card reader, surface mounted raceway, patch holes in masonry and wood trim. Remove existing emergency push to exit button and surface mounted raceway, patch holes in masonry. Remove existing motion sensor, patch holes in masonry and wood trim.
Remove existing magnetic lock, patch holes in masonry and wood trim Remove existing exposed mortise deadlatch, patch door. Remove existing rim panic, patch holes in door Refurbish and reinstall existing strap hinges, hinge hardware and backing plates.
Refurbish and reinstall existing flush bolts.
Refurbish and reinstall pull handles and plates. Refurbish and reinstall window bars.
Refurbish and reinstall existing astragal.
Refurbish and reinstall existing hold-open hardware.
1 A156.3 Mortise panic, classroom function 628
1 A156.5 Mortise cylinder 628
1 A156.16 6 by 12 inches (+-). Push pad with custom "PUSH" engraving field verify size is large enough to cover the patch from the existing mortice deadlatch
2 A156.22 Door sweeps
2 A156.4 Surface Closers, push side 690
Hardware Set #023 Interior Office Doors 108, 109, 110, 111, 112, 203, 204, 207, 209, 210, 213, 214, 215, 221, 222A, 222B, 222C, 222D, 223A, 223B, 223C, 223D, 226, 227, 235A, 235B, 235C, 235D, 238A, 238B, 238C, 250A, 250B, 250C, 253A, 253B, 253C, 259, 260, 261, 262, 263, 265, 304, 307,311, 312B, 313, 314, 315, 341, 342, 343, 346, 347, 417, 419, 420, 444, 445, 450, 451, 464, 523, 524, 525, 528 and 529
SECTION 08 71 00 Page 25
4 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset - office function
1 A156.16 Wall Stop 630
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #024 Interior Classroom Door 113 Qty BHMA/ANSI Government Description BHMA Finish
A156.1 Butt Hinges (By door manufaturer)
1 A156.13 Mechanical Push-Button Mortise Lockset -classroom function
1 A156.4 Surface Closer (pull side mounting) 689 Match Door
1 156.16 Wall Stop 630
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #025 Interior Passage Doors 264 Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - passage function 630
1 A156.16 Wall Stop 630
Hardware Set #026 Interior Classroom Doors 325 and 326
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset classroom function
1 A156.3 Rim Exit Device 630
SECTION 08 71 00 Page 26
Gasketing (at head, jambs, and sill to comply with UL 1784)
1 A156.4 Overhead stop push side 689 Match Door
Theory of Operation: Door is always open from interior side and locked from exterior. Door is unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is unlatched from interor side by use of exit device. Door is automatically relocked upon closing. Door is fail secure.
Hardware Set #027 Interior Classroom Doors 126, 146, 147, 436 and 455
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset classroom function
1 A156.4 Surface Closer with stop function - pull side mounting
689 Match Door
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #028 Interior Janitor, Storage Comm Chase Doors
108A, 113A, 117A, 121 and 316
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function 630
1 A156.16 Wall Stop 630
Hardware Set #029 Interior Automatic Sliding Vestibule Doors 134B and 229B
FORCED ENTRY RESISTANT
Qty BHMA/ANSI Government Description BHMA Finish
SECTION 08 71 00 Page 27
CBurdick Text Box , 313A
CBurdick Cloud
1 A156.5 Cylinder 630
Emergency Exit devices (Provided by door manufacture)
Emergency Closers (Provided by door manufacture)
689 Match Door
Theory of Operation: Door opens from exterior by use of access control device as provided under Section 28 10 05. Egress from interior is activated by motion sensor device as provided under Section 28 10 05. Exit devices operate emergency breakout function when power is out. Sliding leaves are locked in place when doors closed and unlock to allow door operation when activated by access control device or unlocked by keyed cylinder.
Hardware Set #030 Interior Water Service Room Paired Door 138 Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function - Active Leaf
1 A156.16 Flush Bolts - Inactive Leaf 630
2 A156.16 Wall Stop LH Leaf 630
Hardware Set #031 Interior Stair Enclosure Paired Doors 140A,140B,329A,432A,432B,504A and 504B
Qty BHMA/ANSI Government Description BHMA Finish
8 A156.1 Butt Hinges 630
2 A156.3 Concealed Vertical Rod Exit Device -passage function with lever trim
2 A156.4 Surface Closers (stair enclosure side mounting) 689 Match Door
2 A156.15 Electromagnetic Door Holders 630
Theory of Operation: Both leaves are always open from both interior and exterior sides. Latch bolts operated by exit devices from interior side.
Latch bolt operated by levers from exterior side. Both leaves can be held in the open position by the Electromagnetic door holders during normal conditions. When fire protection systems are activated, the electromagnetic door holder release both doors and the vertical rod latches engage with the floor and head strikes.
Hardware Set #032 Interior Classroom Doors 145 and 436
SECTION 08 71 00 Page 28
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset -classroom function
1 A156.16 Surface Closer with stop function - pull side 689 Match Door
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #033 Interior Office Doors 157,244,246 and 247 Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mechanical Push-Button Mortise Lockset -office function
1 A156.16 Wall Stop 630
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #034 Interior Storage Doors 158, 242, 245 and 252
Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
3 A156.13 Mortise Lockset - Storeroom Function 630
3 A156.16 Wall Stop 630
Hardware Set #035 Interior Toilet Room Door 159 and 160 Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.6 Push/Pull Operating hardware:3" by 12" by 0.062" thick rounded Corner Push Plate and 1" diameter, 8" offset pull
SECTION 08 71 00 Page 29
1 A156.4 Surface Closer -Pull Side 689 Match door
2 A156.16 Wall Stop 630
Hardware Set #036 Interior Horizontal Exit Paired Smoke Doors 201 and 301 Qty BHMA/ANSI Government Description BHMA Finish
8 A156.1 Butt Hinges 630
1 A156.3 Concealed Vertical Rod Exit Device - passage function
2 A156.4 Surface Closer (push side mounting) 689 Match Door
2 A156.15 Electromagnetic Door Holders 630
1 A156.22 Gasketing: (at head, jambs and meeting stile) to comply with UL 1784 black
Hardware Set #037 Interior Classroom Doors 217
Qty BHMA/ANSI Government Description BHMA Finish
4 A156.1 Butt Hinges 630
1 A156.3 Mechanical Push-Button Mortise Lockset Classroom Function
1 A156.4 Surface Closer (pull-side mounting) 689 Match Door
1 A156.16 Wall Stop 630
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #038 Interior Unequal Leaf Paired Smoke Doors 218 and 323 Qty BHMA/ANSI Government Description BHMA Finish
8 A156.1 Butt Hinges 630
1 A156.3 Concealed Vertical Rod Exit Device (Unequal Leaves) - passage function
2 A156.4 Surface Closer (push side mounting) 689 Match Door
SECTION 08 71 00 Page 30
2 A156.15 Electromagnetic Door Holders 630
1 A156.22 Gasketing: (at head, jambs and meeting stile) Black
Hardware Set #039 Interior Office Doors 222, 223 and 224 Qty BHMA/ANSI Government Description BHMA Finish
Butt Hinges (By door manufacturer)
1 A156.13 Mechanical Push-Button Mortise Lockset -office function
1 A156.16 Floor Stop 630
Theory of Operation: Door is always open from interior side and locked from exterior. Door unlocked from exterior by use of mechanical cipher lock or by keyed cylinder. Door is automatically relocked upon closing.
Door is fail secure.
Hardware Set #040 Interior Stair Enclosure Paired Door 231A
Qty BHMA/ANSI Government Description BHMA Finish
6 A156.1 Butt Hinges 630
2 A156.3 Concealed Vertical Rod Exit Device - passage function with lever trim
2 A156.4 Surface Closers (stair enclosure-side mounting) 689 Match Door
2 A156.15 Electromagnetic Door Holders 630
2 A156.15 Electromagnetic Door Holders 630
Theory of Operation: Both leaves are always open from both interior and exterior sides. Latch bolt operated by exit devices from interior side.
Latch bolt operated by levers from exterior side. Both leaves can be held in the open position by the Electromagnetic hold opens during normal conditions. When fire protection systems are activated, the electromagnetic hold opens release both doors and the vertical rod latches engage with the floor and head strikes.
Hardware Set #041 Interior Stair Enclosure Paired Door 231B
SECTION 08 71 00 Page 31
6 A156.1 Butt Hinges 630
2 A156.3 Concealed Vertical Rod Exit Device - passage function with lever trim
2 A156.4 Surface Closers (stair enclosure-side mounting) 689 Match Door
2 A156.15 Electromagnetic Door Holders 630
1 A156.22 Gasketing: (at head, jambs and meeting stile) to comply with UL 1784
Black
Theory of Operation: Both leaves are always open from both interior and exterior sides. Latch bolt operated by exit devices from interior side.
Latch bolt operated by levers from exterior side. Both leaves can be held in the open position by the Electromagnetic hold opens during normal conditions. When fire protection systems are activated, the electromagnetic hold opens release both doors and the vertical rod latches engage with the floor and head strikes.
Hardware Set #042 Existing Interior Stair Door 231C Qty BHMA/ANSI Government Description BHMA Finish
Remove existing lockset patch holes
1 A156.13 Replace existing lockset with:
Mortise Lockset storeroom function
3 A156.1 Remove existing butt hinges Replace existing butt hinges with:
Butt Hinges - verify existing size. Patch any holes left after Removals
All other existing hardware to remain.
Hardware Set #043 Interior Janitor Doors 233,331 and 434 Qty BHMA/ANSI Government Description BHMA Finish
3 A156.1 Butt Hinges 630
1 A156.13 Mortise Lockset - storeroom function 630
1 A156.16 Floor Stop 630
Hardware Set #044 Interior Electrical Room Doors 248,348,452 and 530
SECTION 08 71 00 Page 32
3 A156.1 Butt Hinges 630
1 A156.3 Rim Exit Device - storeroom function 630
1 A156.6 Lever Trim 630
1 A156.4 Surface Closer with stop function - push side mounting
689 (Match Door)
1 A156.16 Floor Stop 630
Hardware Set #045 Office Suite Paired Controlled Access Door 254A Qty BHMA/ANSI Government Description BHMA Finish
Bu…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .