About this file

This is an electrical engineering drawing set for the United States Military Academy at West Point, NY, specifically detailing electrical infrastructure components. The document includes multiple technical drawings focused on lightning protection installation details, ductbank conduit configurations, and smoke damper wiring diagrams. Key technical specifications include ductbank details with 4000 PSI concrete, multiple conduit schedules for service feeders and electrical circuits, and lightning protection mounting instructions for equipment such as exhaust fans and rooftop units. The drawings are part of a project (Job No. 219208.00) with a solicitation number W912DS19C0034QPK, issued by the US Army Corps of Engineers New York District, with submission dates of 09/12/2025 and 10/13/2025 noted as addendum dates. The technical drawings provide precise installation guidelines for electrical infrastructure components, including conduit spacing, concrete embedment, and bonding requirements for various electrical and mechanical systems.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS25RA0020009 SF 30.pdf PDF
Solicitation Amendment W912DS25RA0020008 SF 30.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
I-100.3_AM 6.pdf PDF
I-100.2_AM 6.pdf PDF
AD-101_AM 6.pdf PDF
A-304_AM 6.pdf PDF
A-315_AM 6.pdf PDF
A-503_AM 6.pdf PDF
A-003_AM 6.pdf PDF
A-002_AM 6.pdf PDF
H-103_AM 6.pdf PDF
H-104_AM 6.pdf PDF
H-102_AM 6.pdf PDF
H-001_AM 6.pdf PDF
H-108_AM 6.pdf PDF
MP-102_AM 6.pdf PDF
MH-104_AM 6.pdf PDF
M-505_AM 6.pdf PDF
S-316_AM 6.pdf PDF
S-311_AM 6.pdf PDF
S-310_AM 6.pdf PDF
S-113_AM 6.pdf PDF
S-110_AM 6.pdf PDF
S-109_AM 6.pdf PDF
S-001_AM 6.pdf PDF
Submittal Register_AM 6.pdf PDF
Appendix G_AM 5.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
A-601_AM 4.pdf PDF
Solicitation Amendment W912DS25RA0020004 SF 30.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
MS-100_AM3.pdf PDF
01 91 19_AM3.pdf PDF
01 30 00_AM3.pdf PDF
A-319.pdf PDF
E-513.pdf PDF
A-121.pdf PDF
07 60 00.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
MSEC- Building 606 - Amendment 1 - RFIs - 20 Aug 25.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 4.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 1.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AIR TERMINAL

BONDING PLATE

TIE TO LP SYSTEM

ON ROOF (TYP)

AIR TERMINAL

BONDING PLATE (TYP.

AT EACH DOWNLEAD)

TIE TO LP SYSTEM

ON ROOF (TYP)

ILLUSTRATED ABOVE ARE TYPICAL

INSTALLATION DETAILS. REFER TO

GENERAL INSTALLATION NOTES FOR

BONDING REQUIREMENTS. ACTUAL

BONDING TO BE DETERMINED IN THE

FIELD. NO POINTS REQUIRED ON

METAL OBJECTS 3/16" THICK.

BELOW ROOF

RUN IN CLG. SPACE

BONDING CONDUCTOR

TYPICAL AIR TERMINAL

BUILDING PARAPET

MTD. AIR TERMINAL

TYPICAL EQUIPMENT

BONDING CONDUCTOR LOOP

TYPICAL SIDE MOUNTED

NOTE:

ADDRESSABLE DUCT SMOKE DETECTOR:

FURNISHED BY DIV. 28 CONTRACTOR;

INSTALLED BY DIV. 23 CONTRACTOR.

WIRED TO BAS BY DIV. 25 CONTRACTOR;

WIRED TO FIRE ALARM BY DIV. 28 CONTRACTOR.

SMOKE DAMPER (SPRING-CLOSED, POWER TO OPEN): SUPPLIED AND

INSTALLED BY DIV. 23 CONTRACTOR. POWERED BY DIV. 26

CONTRACTOR.

ADDRESSABLE INTERFACE MODULE BY DIV. 28

NORMALLY CLOSED CONTACT OF

ADDRESSABLE INTERFACE MODULE

BY DIV. 28

1. FIRE ALARM SYSTEM TO CLOSE SMOKE DAMPER UPON

ACTIVATION OF DUCT MOUNTED SMOKE DETECTOR, AND SEND

SIGNAL TO DDC SYSTEM SO BAS SYSTEM WILL SHUT DOWN FAN

SYSTEM.

2. BAS SYSTEM SHALL SEND SIGNAL TO FIRE ALARM SYSTEM WHEN FAN

SYSTEM IS TO BE ENERGIZED. FA SYSTEM SHALL OPEN ALL SMOKE

DAMPER. AFTER A TIME DELAY, DDC SHALL START FAN SYSTEM.

3. WHENEVER DDC SHUTS DOWN A FAN SYSTEM (IN A NON-FIRE

RELATED SITUATION), THE DDC SYSTEM SHALL CLOSE ALL SMOKE

DAMPERS.

N H

120V WIRING

(BY DIV. 26)

TO FIRE ALARM SYSTEM

C TO FIRE ALARM

SYSTEM BY DIV. 28

STAGGER COUPLINGS

BOTH HORIZONTALLY

AND VERTICALLY

TYPICAL CONDUIT

SPACERS

DUCTBANK CONCRETE

ENVELOPE

4" MIN.

2" MIN.

UNDISTURBED

EARTH

(6) 4" SCH. 40

PVC TYPICAL

4000 PSI CONCRETE

#4 DEFORMED BAR

EACH CORNER

DEPTH AS

SPECIFIED

36" MIN

FINISHED GRADE

YELLOW LINE MARKER AS

SPECIFIED 18" BELOW GRADE

ENTIRE WIDTH OF DUCTBANK

TOP 1" SHALL BE SPRINKLED AND

THROUGHLY MIXED WITH RED DYE

#3 STIRRUPS,

4'-0" ON CENTER

-1

/2

M

IN

5"

CONDUIT SPACERS

5"

29 -1/2"

CONDUIT SCHEDULE

1 - ACTIVE - SERVICE FEEDER

2 - ACTIVE - SERVICE FEEDER

3 - ACTIVE-SERVICE FEEDER

7-1/2"

MIN.

7-1/2"

MIN.

4 - ACTIVE - SERVICE FEEDER

5 - ACTIVE - SERVICE FEEDER

6 - SPARE, PULLWIRE ONLY

UNDISTURBED

EARTH

(9) SCH. 40 PVC

4000 PSI CONCRETE

#4 DEFORMED BAR

EACH CORNER

DEPTH AS

SPECIFIED

36" MIN

FINISHED GRADE YELLOW LINE MARKER AS

SPECIFIED 18" BELOW GRADE

ENTIRE WIDTH OF DUCTBANK

TOP 1" SHALL BE SPRINKLED AND

THROUGHLY MIXED WITH RED DYE

#3 STIRRUPS,

4'-0" ON CENTER

-1

/2

M

IN

5"

CONDUIT SPACERS

5"

29 -1/2"

CONDUIT SCHEDULE

1 ACTIVE - 4"C - TEMP CHILLER FEEDER

2 ACTIVE - 2"C - TEMP GEN. FEEDER(FIRE PUMP)

3 ACTIVE - 1"C - RECEPT BRANCH CKT AP-EB-1 #1

4 ACTIVE - 1"C - RECEPT BRANCH CKT AP-EB-1 #40,42

5 ACTIVE - 4"C - TEMP CHILLER FEEDER

6 ACTIVE - 4"C - TEMP GEN. FEEDER

7 ACTIVE - 4"C - TEMP GEN. FEEDER

8 ACTIVE - 4"C - TEMP GEN. FEEDER

9 ACTIVE - 4"C - TEMP GEN. FEEDER

10 ACTIVE - 4"C - TEMP GEN. FEEDER

7-1/2"

MIN.

7-1/2"

MIN.

8 9 10

-1

/2

M

IN

3 4

2 RESPONSE TO RFI #345

NOT FOR

CONSTRUCTION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

E-512

D E

T A

IL

S

E

L E

C T

R

IC

A L

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T N

Y P

/N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

M J P

M J P

D K

M

A Y

W D

S C

Q P

K J

O B

N O

.0

REV RTA SUBMISSION

R E

P A

IR

B

L D

G

G

E N

E R

A L I N

S T

R U

C T

IO

N

B L D

G

SCALE: NTSE-512

LIGHTNING PROTECTION - EXHAUST FAN AIR TERMINALA8

SCALE: NTSE-512

LIGHTNING PROTECTION - RTUA5

SCALE: NTSE-512

LIGHTNING PROTECTION TYPICAL INSTALLATIONA2

SCALE: NTSE-512

DUCT SMOKE DAMPER WIRING DIAGRAMD8

SCALE: NTSE-512

DUCTBANK CONDUIT COUPLINGSD5

SCALE: NTSE-512

DUCTBANK DETAIL - A-AD2

A

D D

E N

D U

M

/1

/2

A

D D

E N

D U

M

/1

/2

SCALE: NTSE-512

DUCTBANK DETAIL - B-BF5

File details come from the government source that posted it. Updated .