About this file

This architectural drawing is a building section for West Point Building 606, specifically showing a core section looking east. The detailed technical drawing includes multiple floor levels, elevator lobbies, and various architectural elements such as skylights, curtain wall systems, and material specifications. Key architectural components include existing limestone, granite, metal panel systems, precast concrete elements, and custom curtain wall details. The drawing provides technical cross-sectional views with precise measurements, material annotations, and construction specifics for different floor levels, with a focus on structural and exterior design elements. Detailed notes describe materials like insulated metal panels, fixed steel ladders, and specific wall system compositions, indicating a comprehensive architectural design for a multi-story building project.

View the file

Other files

File Type Posted
Solicitation Amendment W912DS25RA0020009 SF 30.pdf PDF
Solicitation Amendment W912DS25RA0020008 SF 30.pdf PDF
E-512_AM 7.pdf PDF
I-108_AM 6.pdf PDF
I-105_AM 6.pdf PDF
I-100.3_AM 6.pdf PDF
I-100.2_AM 6.pdf PDF
AD-101_AM 6.pdf PDF
A-304_AM 6.pdf PDF
A-315_AM 6.pdf PDF
A-503_AM 6.pdf PDF
A-003_AM 6.pdf PDF
A-002_AM 6.pdf PDF
H-103_AM 6.pdf PDF
H-104_AM 6.pdf PDF
H-102_AM 6.pdf PDF
H-001_AM 6.pdf PDF
H-108_AM 6.pdf PDF
MP-102_AM 6.pdf PDF
MH-104_AM 6.pdf PDF
M-505_AM 6.pdf PDF
S-316_AM 6.pdf PDF
S-311_AM 6.pdf PDF
S-310_AM 6.pdf PDF
S-113_AM 6.pdf PDF
S-110_AM 6.pdf PDF
S-109_AM 6.pdf PDF
S-001_AM 6.pdf PDF
Submittal Register_AM 6.pdf PDF
Appendix G_AM 5.pdf PDF
A-602_AM 4.pdf PDF
A-564_AM 4.pdf PDF
M-303_AM3.pdf PDF
E-512 - DETAILS - ELECTRICAL_AM3.pdf PDF
MSEC- Building 606 - Amendment 3 - RFIs - 16 Sep 25.pdf PDF
Solicitation Amendment W912DS25RA0020003 SF 30.pdf PDF
A-319.pdf PDF
Site Walk through sign in sheet_04Sept25.pdf PDF
S-318.pdf PDF
S-112.pdf PDF
A-406.pdf PDF
A-122.pdf PDF
Solicitation Amendment W912DS25RA0020001 SF 30.pdf PDF
Solicitation - W912DS25RA002.pdf PDF
JA-007-25 Monaco Fire Alarm MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
JA-004-25 Best Cylinders MSEC - 31 Jan 25 signedJF sDL -_Redacted.pdf PDF
JA-008-25 IDS MSEC - 31 Jan 25 signedJF sDL_Redacted.pdf PDF
JA-006-25 CAC MSEC - 31 Jan 25 signedJF sDL -_Redacted.pdf PDF
W912DS19C0034 PN 94078 Repair Building 606 Revised RTA Drawings - Volume 3.pdf PDF
W912DS19C0034 PN 94078 Repair building 606 REV.RTA Specification Manual Volume 2.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NORTH

TOSL-1ST FLR (159'-3")

0"

TOSL-2ND FLR (172'-3")

13' - 0"

TOSL-3W FLR (183'-6")

24' - 3"

TOSL-4W FLR (196'-10")

37' - 7"

TOSL-5W FLR (208'-6")

49' - 3"

BA BBAB AC CL1 AD AE DBDA DC

E1

A-301

W92 W92 W92

BL19 BL19 BL19 BL19 BL19 BL19

SKYLIGHT

SKYLIGHT

WELLNESS RM

HC TLT

ELEV LOBBY

ELEV LOBBY

ELEV LOBBY

ELEV LOBBY

A-314

D1

SIM,

OPH

A-305

C8

A-314

C4

SIM,

OPH

A-315

A8 A-315

A8

A-314

A4 SIM,

OPH

A-315

A3

1'

3/

4"

WATER SERVICE &

BACKFLOW

PREVENTER

TOS - INFILL (221'-10")

62' - 7"

SIM,

OPH

BL24 BL24 BL24

BL24 BL24 BL24

A-314

D1

A-314

A1

A-314

A1

SIM

BL22

A-555

D8

A-555

A1

03 04

ROOF OVERFLOW

DOWNSPOUT; SEE

PLUMBING DRAWINGS.

BC

BL21 BL21 BL22

BL20 BL20 BL20 BL20

BL20 BL20 BL20 BL20

AREA OF 2 HOUR RATED

FLOOR ENCLOSURE,

REFER TO DETAILS.

BORROWED LITES,

HIDDEN BEYOND, REFER

TO SCHEDULE, AND

DETAILS.

BL22BL22

ELEV LOBBY

A-305

A1

AREA OF 2 HOUR RATED FLOOR

ENCLOSURE, REFER TO DETAILS.

B5

A-406

A-315

E6

OPH

TOSL-5W FLR (208'-6")

49' - 3"

POUR STOP; REFER TO

STRUCT DWGS.

FIRE SAFING (TYP @

EACH FLOOR LINE).

INSULATED SPANDREL

PANEL; SEAL FULL

PERIMETER AT CURTAIN

WALL FRAME (TYP).

PROVIDE MET SKIN TO

MATCH CURTAIN WALL

WHEN EXPOSED TO

INTERIOR (TYP)

1 5/8" OR 2 1/2" STUDS @ 16" OC

STEEL CLIP @

48" OC (TYP)

CONT FRAMING

ANGLE (TYP)

TOSL-4W FLR (196'-10")

37' - 7"

INS SPANDREL

GLAZING; SEE EL'S.

CURTAIN WALL SYSTEM;

REFER TO ELEVATIONS.

FLOORING, AS

SCHEDULED.

CONC SLAB ON METAL

DECK; SEE

STRUCTURAL DWGS.

POUR STOP; REFER TO

STRUCT DWGS.

FIRE SAFING (TYP @

EACH FLOOR LINE).

HVAC EQUIP; SEE

MECHANICAL DWGS.

STEEL COL; REFER TO

STRUCT DWGS.

PROVIDE REQD

FIREPROOFING (TYP).

CURTAIN WALL CLIP

SYSTEM; ATTACH TO

STRUCTURE.

1 1/2"

INSULATED SPANDREL

PANEL; SEAL FULL

PERIMETER AT CURTAIN

WALL FRAME (TYP).

PROVIDE MET SKIN TO

MATCH CURTAIN WALL

WHEN EXPOSED TO

INTERIOR (TYP)

STEEL BEAM; SEE

STRUCT DWGS,

PROVIDE REQD

FIREPROOFING (TYP).

WOOD SYSTEM

WITH Z CLIPS

6"

CMU INFILL.

7/12 SLOPED CLG. GWB SOFFIT.

STL BEAM.

STEEL COL BEYOND.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt

10/13/2025 2:32:22 PM

A-305

B U

IL

D

IN

G

S E

C T

IO

N

S

U N

IT

E

D S

T A

T E

S M

IL

IT

A R

Y A

C A

D E

M Y

W

E S

T P

O

IN

T

N Y

P N

F

Y

N E

W Y

O R

K D

IS

T

R

IC

T N

E W

Y O

R K

N

Y

W D

R

E A

L

M P

K

V N

S

E P

T E

M B

E R

W

D

S

C

Q P

K J

O B

N O

.0

ADDENDUM #6

R E

P A

IR

B

L D

G

G E

N E

R A

L I N

S T

R U

C T

IO

N

B L

D G

C1

A-305

SCALE: NO SCALE

KEY PLAN

04 8 16268

SCALE: 1/8" = 1'-0"

SCALE: 1/8" = 1'-0"C1

BUILDING SECTION - CORE LOOKING EAST

KEYED NOTES - ELEVATIONS & SECTIONS

NUMBER COMMENT

01 EXISTING LIMESTONE.

02 EXISTING GRANITE.

03 INSTALL SALVAGED LIMESTONE COPING; REFER TO ROOF PLAN & DETAILS.

03A EXISTING LIMESTONE COPING; REPLACE SEALANTS, PROVIDE WEEPS, AND PROVIDE

LEAD "T" COVERS. REFER TO ROOF PLANS, DETAILS, AND PRESERVATION DWGS.

04 EXISTING LIMESTONE TRIM BAND.

05 INSULATED METAL PANEL SYSTEM.

06 OVERFLOW SCUPPER; REFER TO PLUMBING DRAWINGS.

07 FIXED GALVANIZED STEEL LADDER.

08 ROOFTOP EQUIPMENT METAL PANEL SCREENING.

09 ENTRY STAIRS AND HANDRAIL; REFER TO CIVIL DRAWINGS.

10 CURTAIN WALL SYSTEM.

11 EXISTING LIMESTONE WINDOW SURROUND.

12 EXISTING BRICK.

13 BRICK VENEER - RUNNING BOND. MATCH EXST ADJACENT BRICK SIZE, COLOR, AND

TEXTURE. RETURN BRICK AT EXPOSED ENDS TO BACK OF PARAPET WALL.

14 EXISTING CONCRETE.

15 CUSTOM CURTAIN WALL CAP PROFILE TYPE A. REFER TO PLAN DETAIL.

16 CUSTOM CURTAIN WALL CAP PROFILE TYPE B. REFER TO PLAN DETAIL.

17 CURTAIN WALL METAL CORNER TRIM; MATCH COLOR OF CURTAIN WALL FRAME.

18 PRECAST CONCRETE COPING.

19 EXST PRECAST WINDOW LINTEL / SILL.

20 MCM WALL SYSTEM.

21 LIGHT FIXTURE / EXIT SIGN; REFER TO ELECTRICAL DRAWINGS.

22 INSTALL SALVAGED LIMESTONE PANELS; REFER TO SECTION DETAIL.SCALE: 1 1/2" = 1'-0"A1

SECTION DTL - CORE LOOKING EAST

SCALE: 1 1/2" = 1'-0"C8

SECTION DTL - CURTAIN WALL @ 4TH FLOOR STEP

A

D D

E N

D U

M

/1

/2

File details come from the government source that posted it. Updated .