A-305_AM 6.pdf
PDF 804 KB Posted
- Solicitation number
- W912DS25RA002
About this file
This architectural drawing is a building section for West Point Building 606, specifically showing a core section looking east. The detailed technical drawing includes multiple floor levels, elevator lobbies, and various architectural elements such as skylights, curtain wall systems, and material specifications. Key architectural components include existing limestone, granite, metal panel systems, precast concrete elements, and custom curtain wall details. The drawing provides technical cross-sectional views with precise measurements, material annotations, and construction specifics for different floor levels, with a focus on structural and exterior design elements. Detailed notes describe materials like insulated metal panels, fixed steel ladders, and specific wall system compositions, indicating a comprehensive architectural design for a multi-story building project.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NORTH
TOSL-1ST FLR (159'-3")
0"
TOSL-2ND FLR (172'-3")
13' - 0"
TOSL-3W FLR (183'-6")
24' - 3"
TOSL-4W FLR (196'-10")
37' - 7"
TOSL-5W FLR (208'-6")
49' - 3"
BA BBAB AC CL1 AD AE DBDA DC
E1
A-301
W92 W92 W92
BL19 BL19 BL19 BL19 BL19 BL19
SKYLIGHT
SKYLIGHT
WELLNESS RM
HC TLT
ELEV LOBBY
ELEV LOBBY
ELEV LOBBY
ELEV LOBBY
A-314
D1
SIM,
OPH
A-305
C8
A-314
C4
SIM,
OPH
A-315
A8 A-315
A8
A-314
A4 SIM,
OPH
A-315
A3
1'
3/
4"
WATER SERVICE &
BACKFLOW
PREVENTER
TOS - INFILL (221'-10")
62' - 7"
SIM,
OPH
BL24 BL24 BL24
BL24 BL24 BL24
A-314
D1
A-314
A1
A-314
A1
SIM
BL22
A-555
D8
A-555
A1
03 04
ROOF OVERFLOW
DOWNSPOUT; SEE
PLUMBING DRAWINGS.
BC
BL21 BL21 BL22
BL20 BL20 BL20 BL20
BL20 BL20 BL20 BL20
AREA OF 2 HOUR RATED
FLOOR ENCLOSURE,
REFER TO DETAILS.
BORROWED LITES,
HIDDEN BEYOND, REFER
TO SCHEDULE, AND
DETAILS.
BL22BL22
ELEV LOBBY
A-305
A1
AREA OF 2 HOUR RATED FLOOR
ENCLOSURE, REFER TO DETAILS.
B5
A-406
A-315
E6
OPH
TOSL-5W FLR (208'-6")
49' - 3"
POUR STOP; REFER TO
STRUCT DWGS.
FIRE SAFING (TYP @
EACH FLOOR LINE).
INSULATED SPANDREL
PANEL; SEAL FULL
PERIMETER AT CURTAIN
WALL FRAME (TYP).
PROVIDE MET SKIN TO
MATCH CURTAIN WALL
WHEN EXPOSED TO
INTERIOR (TYP)
1 5/8" OR 2 1/2" STUDS @ 16" OC
STEEL CLIP @
48" OC (TYP)
CONT FRAMING
ANGLE (TYP)
TOSL-4W FLR (196'-10")
37' - 7"
INS SPANDREL
GLAZING; SEE EL'S.
CURTAIN WALL SYSTEM;
REFER TO ELEVATIONS.
FLOORING, AS
SCHEDULED.
CONC SLAB ON METAL
DECK; SEE
STRUCTURAL DWGS.
POUR STOP; REFER TO
STRUCT DWGS.
FIRE SAFING (TYP @
EACH FLOOR LINE).
HVAC EQUIP; SEE
MECHANICAL DWGS.
STEEL COL; REFER TO
STRUCT DWGS.
PROVIDE REQD
FIREPROOFING (TYP).
CURTAIN WALL CLIP
SYSTEM; ATTACH TO
STRUCTURE.
1 1/2"
INSULATED SPANDREL
PANEL; SEAL FULL
PERIMETER AT CURTAIN
WALL FRAME (TYP).
PROVIDE MET SKIN TO
MATCH CURTAIN WALL
WHEN EXPOSED TO
INTERIOR (TYP)
STEEL BEAM; SEE
STRUCT DWGS,
PROVIDE REQD
FIREPROOFING (TYP).
WOOD SYSTEM
WITH Z CLIPS
6"
CMU INFILL.
7/12 SLOPED CLG. GWB SOFFIT.
STL BEAM.
STEEL COL BEYOND.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P R
O J E
C T
N O
Autodesk Docs://West Point Bldg 606/219208-WP606-A20.rvt
10/13/2025 2:32:22 PM
A-305
B U
IL
D
IN
G
S E
C T
IO
N
S
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W
E S
T P
O
IN
T
N Y
P N
F
Y
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
N
Y
W D
R
E A
L
M P
K
V N
S
E P
T E
M B
E R
W
D
S
C
Q P
K J
O B
N O
.0
ADDENDUM #6
R E
P A
IR
B
L D
G
G E
N E
R A
L I N
S T
R U
C T
IO
N
B L
D G
C1
A-305
SCALE: NO SCALE
KEY PLAN
04 8 16268
SCALE: 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"C1
BUILDING SECTION - CORE LOOKING EAST
KEYED NOTES - ELEVATIONS & SECTIONS
NUMBER COMMENT
01 EXISTING LIMESTONE.
02 EXISTING GRANITE.
03 INSTALL SALVAGED LIMESTONE COPING; REFER TO ROOF PLAN & DETAILS.
03A EXISTING LIMESTONE COPING; REPLACE SEALANTS, PROVIDE WEEPS, AND PROVIDE
LEAD "T" COVERS. REFER TO ROOF PLANS, DETAILS, AND PRESERVATION DWGS.
04 EXISTING LIMESTONE TRIM BAND.
05 INSULATED METAL PANEL SYSTEM.
06 OVERFLOW SCUPPER; REFER TO PLUMBING DRAWINGS.
07 FIXED GALVANIZED STEEL LADDER.
08 ROOFTOP EQUIPMENT METAL PANEL SCREENING.
09 ENTRY STAIRS AND HANDRAIL; REFER TO CIVIL DRAWINGS.
10 CURTAIN WALL SYSTEM.
11 EXISTING LIMESTONE WINDOW SURROUND.
12 EXISTING BRICK.
13 BRICK VENEER - RUNNING BOND. MATCH EXST ADJACENT BRICK SIZE, COLOR, AND
TEXTURE. RETURN BRICK AT EXPOSED ENDS TO BACK OF PARAPET WALL.
14 EXISTING CONCRETE.
15 CUSTOM CURTAIN WALL CAP PROFILE TYPE A. REFER TO PLAN DETAIL.
16 CUSTOM CURTAIN WALL CAP PROFILE TYPE B. REFER TO PLAN DETAIL.
17 CURTAIN WALL METAL CORNER TRIM; MATCH COLOR OF CURTAIN WALL FRAME.
18 PRECAST CONCRETE COPING.
19 EXST PRECAST WINDOW LINTEL / SILL.
20 MCM WALL SYSTEM.
21 LIGHT FIXTURE / EXIT SIGN; REFER TO ELECTRICAL DRAWINGS.
22 INSTALL SALVAGED LIMESTONE PANELS; REFER TO SECTION DETAIL.SCALE: 1 1/2" = 1'-0"A1
SECTION DTL - CORE LOOKING EAST
SCALE: 1 1/2" = 1'-0"C8
SECTION DTL - CURTAIN WALL @ 4TH FLOOR STEP
A
D D
E N
D U
M
/1
/2
File details come from the government source that posted it. Updated .