This document contains interior elevation drawings and notes for the Army Reserve Training Center in Willow Grove, Pennsylvania. The drawings depict wall, door, and casework details for several building areas including the lobby, corridors, and mailroom. Notable elements in the drawings include metal wall panels, wood doors, horizontal mailboxes, tack boards, display cases, and directional signage. The general notes provide information on partition types, corner guards, furniture layouts, dimensions, mounting heights, and finish schedules.

The related federal contract opportunity is a special notice for HVAC system repairs at the PA 206 Horsham facility. Solicitation number W912BU24R0001 seeks offers for repairs to the HVAC systems at the Horsham site. The contracting agency is the Department of the Army Corps of Engineers Engineering District in Philadelphia. No further details are provided on response dates, pricing terms, or other procurement requirements.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/4" = 1’-0" A4 00-A-410

INTERIOR ELEVATION

1/4" = 1’-0" B4

INTERIOR ELEVATION

1/4" = 1’-0" C4

INTERIOR ELEVATION

1/4" = 1’-0" D4

INTERIOR ELEVATION

1/4" = 1’-0" B2

INTERIOR ELEVATION

1/4" = 1’-0" A2

INTERIOR ELEVATION

1/4" = 1’-0"

A1

INTERIOR ELEVATION

B1

INTERIOR ELEVATION

1/4" = 1’-0"

1/4" = 1’-0"

INTERIOR ELEVATION

C1

T R

A

IN

IN

G C

E N

T E

R

IN

T E

R

IO

R E

L E

V A

T

IO

N S

REVISED AS-BUILT

F

IE

L D C

O N

D

IT

IO

N

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-410.dgn

9/11/2012

9:24:11 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

4’ 8’0 2’

SCALE:1/4"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -4

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

00-A-542

A4

00-A-541

C4

A3

2’-6" 2’-9" 2’-6"

FILLER

PANEL

FILLER

PANEL

A3

10 10 10

2 2

Approved By The

Postmaster General

U.S.MAIL

Approved By The

Postmaster General

U.S.MAIL

Approved By The

Postmaster General

U.S.MAIL

00-A-703

C2

CORRIDOR

BEYOND

OPEN TO

LOBBY

TYP.

TYP.

TYP.

TYP.

LOBBY ENTRY FROM BEYOND

CORRIDOR

BEYOND

CORRIDOR

BEYOND

FILLER

3’-0" 3’-0" 3’-0" 3’-0" 3’-0" 3’-0" 3’-0"

C4

00-A-541

9 DOOR 4C HORIZONTAL MAILBOXES WITH 2 1/4" TRIM

ALONG THE OUTER PERIMETER, SEE SPECIFICATIONS FOR

MORE INFORMATION

PAINTED GYP. BOARD WALL, SEE FINISH SCHEDULE FOR

INFORMATION

SCHEDULED RESILIENT BASE, SEE FINISH SCHEDULE FOR

INFORMATION

BUILDING DIRECTORY BOARD

ENCLOSED TACK BOARD

MINUTEMAN PLAQUE (GFCI)

CARD READER, SEE ELECTRICAL DRAWINGS FOR MORE

INFORMATION

SEMI-RECESSED FIRE EXTINGUISHER CABINET

FIRE ALARM CONTROL PANEL, SEE ELECTRICAL PLANS FOR

MORE INFORMATION

WOOD DOOR WITH PAINTED HM FRAME, SEE FINISH

SCHEDULE FOR INFORMATION

CORNER GUARDS

SCHEDULED TILE BASE, SEE FINISH SCHEDULE FOR MORE

INFORMATION

LOCKABLE SLIDING GLASS WINDOW IN H.M. FRAME

8" x8" ACCESS PANELS

NOT USED

RECESSED DISPLAY CASES, SEE MILLWORK SECTIONS FOR

MORE DETAILS

DIRECTIONAL SIGNAGE

SCHEDULED TILE BASE, SEE FINISH SCHEDULE AND PLANS

FOR MORE INFORMATION

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND

00-A-500.

8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.

4’ 8’0 2’

SCALE:1/4"=1’

GENERAL NOTES

GRAPHIC SCALE

KEY NOTES