AFC8A7-1.PDF
PDF 755 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains roofing details and specifications for the Army Reserve Training Center in Willow Grove, Pennsylvania. The details show various roof construction elements including flashing at parapets, penetrations, valleys, and ridges. Specified materials include metal decking, rigid insulation, asphalt shingles, and fully adhered EPDM membrane. Mechanical equipment such as vents and plumbing stacks are also detailed.
The related federal contract opportunity is a special notice for HVAC system repairs at the PA 206 Horsham facility. The solicitation was issued by the U.S. Army Corps of Engineers Philadelphia District. The opportunity involves repair work for HVAC systems but provides no further details on requirements, response dates, or incumbent contractors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-532A4
ROOF DETAIL
3" = 1’-0"3" = 1’-0"
A3 3" = 1’-0"
A2
C3 3" = 1’-0" 3" = 1’-0"
ROOF DETAIL
C4
WATERPROOFING DETAIL AT STEEL LINTEL
3" = 1’-0" B4
ROOF DETAIL - PIPE PENETRATION
C2
FRAMED PARAPET FLASHING DETAIL
N.T.S.
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"0
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"0
SCALE: 3"=1’
3" 6" 9" 12"
SCALE: 3"=1’
3" 6" 9" 12"
DORMER RIDGE DETAIL VALLEY DETAIL
AS-BUILT
T R
A
IN
IN
G C
E N
T E
R R
O O
F D
E T
A
IL
S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-532.dgn
9/11/2012
9:25:50 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -5
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
8"
6"
2" MIN.
/2
/2
137’-3 1/2" T.O.S.
136’-7 3/8" T.O.S.
135’-5 3/8" B.M.D.
METAL DECKING
SEE STRUCTURAL
BAR JOIST
SEE STRUCTURAL
NAILER FACED
RIGID INSUL.
ASPHALT
SHINGLES
CORRUGATED
ROOF VENT
WD. NAILER
BEYOND
FLASHING
ROOF EDGE
INSTALL BRICK TIES OVER
SELF ADHERING MEMBRANE
FLASHING PATCH
EXTERIOR SHEATHING
9" SELF ADHERING MEMBRANE FLASHING
INSTALLED TO SHEATHING BEHIND AIR &
MOISTURE BARRIER (CUT FLAP OPEN)
EXTEND OVER LOWER MEMBRANE
FLASHING MIN. 3"
FOLD AIR & MOISTURE BARRIER FLAP &
SEAL ALL SEAMS w/ STRIP OF SELF
ADHERING MEMBRANE FLASHING
9" SELF ADHERING MEMBRANE FLASHING
OVER AIR & MOISTURE BARRIER, LINTEL &
OVER BACK LEG OF FLASHING PAN
BACKER ROD TO SUPPORT
FLASHING - TYP.
GALV. STL. LINTEL -
SEE STRUCTURAL
NAILER FACED
RIGID INSUL.
ASPHALT
SHINGLES
VENT SPACE
METAL DECKING
SEE STRUCTURAL
METAL DECKING
SEE STRUCTURAL
VENT SPACE
NAILER FACED
RIGID INSUL.
ASPHALT
SHINGLES
ASPHALT
SHINGLES
RIDGE VENT
PRE-FINISHED WIND
DEFLECTION AIR-FOIL
PRE-FINISHED WIND
DEFLECTION AIR-FOIL
PLUMBING VENT
STACK
METAL DECKING
SEE STRUCTURAL
ADHESIVE
LAP SEALANT
PRE-MOLDED
PIPE FLASHING
STAINLESS STEEL
CLAMPING RING
WATER CUT-OFF
MASTIC
RIGID INSUL.
THRU WALL FLASHING
SCHED. BRICK
SELF-ADHERED COUNTER
FLASHING
EXTERIOR GYP. SHEATHING
2 PIECE FLASHING
GALVANIZED FINISH
NON-CORROSIVE FASTENER
@ 24" O.C.
TERMINATION BAR WITH
SEALANT AT TOP OF BAR
LOCKING STRAP
SEE STRUCTURAL
SELF-ADHERED COUNTER
FLASHING
CONTINUOUS P.T. WOOD BLOCKING
W/ STAGGERED ANCHORS @ 32" O.C.
2 PIECE FLASHING
GALVANIZED FINISH
THRU WALL FLASHING
SCHED. BRICK
2" RIGID INSUL.
EXTERIOR GYP. SHEATHING
ON 6" MTL STUDS
SELF-ADHERED FLASHING SADDLE
APPLIED UNDER PARAPET WALL
ROOF MEMBRANE, ON TOP OF
THRU WALL FLASHING AND CONTINUED
VERTICALLY ON MAIN WALL.
ROOF UNDERLAYMENT
ROOF UNDERLAYMENT
FLEXIBLE THRU WALL FLASHING
w/ PREFORMED END DAMS
A.M.B.S.
A.M.B.S.
A.M.B.S.
VENTED WEEPS
@ 24" O.C. (TYP.)
SELF-ADHERING
WATERPROOFING
EPDM MEMBRANE
EPDM ROOF MEMBRANE
FULLY ADHERED EPDM MEMBRANE
WITH WATER CUT OFF SEALANT
EPDM ROOF MEMBRANE
FULLY ADHERED EPDM
MEMBRANE WITH WATER
CUT OFF SEALANT
VALLEY FLASHING
TREATED WOOD BLOCKING
BATT INSUL
A.M.B.S.
EPDM
ROOF MEMBRANE
SELF-ADHERING
MEMBRANE FLASHING
CONTRACTOR OPTION:
PRIVIDE MFR
PROPRIETARY
RIDGE VENT PRODUCT
CONTRACTOR OPTION:
PRIVIDE MFR
PROPRIETARY
RIDGE VENT PRODUCT
File details come from the government source that posted it. Updated .