AFRC55-2.PDF
PDF 1 MB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains a first floor plan and general notes for the PA 206 Horsham HVAC Systems Repairs project. The project involves repairs to the HVAC systems at the Army Reserve Training Center located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The solicitation is being conducted by the Department of the Army Corps of Engineers Engineering District Philadelphia under number W912BU24R0001. The first floor plan depicts the layout of the training center building and notes various features including wall types, equipment locations, and furnishing details. Repairs are needed to address issues with the HVAC systems serving the training center facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-1031/8" = 1’ 0" A4
FIRST FLOOR PLAN - WEST
T R
A
IN
IN
G C
E N
T E
R F
IR
S T F
L O
O R P
L A
N W
E S
T
REVISED AS-BUILT
F
IE
L D C
O N
D
IT
IO
N
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-103.dgn
9/11/2012
9:19:34 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
GENERAL NOTES
KEY PLAN
KEY NOTES
GRAPHIC SCALE
8’0 4’ 16’
SCALE:1/8"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -1
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
20’-4" 20’-7 3/8 " 18’-10 7/8 " 5’-0"
7’-11" 6’-11 7/8 "
2’-0 5/8 "
20’-2" 8’-0 3/4 " 7’-8"
3’-0"
13’-9 3/4 " 17’-3 1/4 "
/4
/8
/2
/4
/8 " 3
" 2
/4
/2
5’-3 1/4 "
/8
28’-10 1/2 "
5’-2 7/8 "
/4
/8
/8
29’-10"
1’-0" 5’-8"6’-4"
1’-8"
10"
10"
2’-6"
S
2C
100A.1100A.2
A
B
A
.1
.2
115.1
115.2
122A.2
122B
122A.3100B.2
100B.1
C
B
123A.1
122A.1
A
B
B
B
A
102A
A .1
B .1
A .2
B .2
118B
121B
A .2
00-A-410 B1
12 12
00-A-410
M A
T C
H L
IN
E
A
-A -1
T
1B
/8
/8
A4
A2
B4
B2
00-A-410
C4
D4
00-A-801
A5
00-A-811
00-A-511
B5
TYP
B5
00-A-511
TYP
A4
00-A-511
TYP
A2
00-A-402
B5
00-A-401
A4
15’-8 1/4 " –4’-6"15’-9 3/4 " –4’-9"
5’-7"8’-10 1/2 " –
4’-6"
8’-10 1/2 " –4’-11 1/2 "
2’-6 1/8 "
/8
/8
2’-0"
/8
3’-0"
2’-5 7/8 "
/8
27’-9"
30’-0"
/8
A
A
A
1’-5"
14’-8"
8’-7"
/4
SIM
00-A-401
D1
5’-4"11’-8 1/2 "
A L
IG
N
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
1C
SW
S
1A
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2D
SW
S
2C
SW
SW
S
1A
SW
S
2F
SW
S
2F
SW
S
2F
SW
S
2F
SW
S
2J
SW
S
2D
SW
S
2F
SW
S
2H
SW
ALIGN ALIGN
A L
IG
N
AT COLUMN
LINE
@ DOOR-
FRAME
@ DOOR-
FRAME
CENTER OF
WALL
S
2G
SW
S
2D
SW
@ DOOR-
FRAME
S
2H
SW
PLAN
NORTH
01 01 01 01 01 01 01 01
CENTER
ON WALL
CENTER
ON WALL
CENTER
ON WALL
S
2L
SW
S
2M
SW
A L
IG
N
CENTER
ON WALL
CENTER
ON WALL
S
2F
SW
S
2A
SW
S
1A
S
1B
S
1B
S
1B
S
1B
S
1B
S
1B
S
2A
SW
ALIGN
4’-8 3/8 "
S
2D
/8
/4
/2
E Q
"6
E Q
/4
CONTROL JOINT, SEE DETAIL ON SHEET 00-A-501 FOR INFORMATION
PROVIDE CHAIR RAIL ON ALL WALLS OF THIS ROOM, SEE MOUNTING HEIGHTS
ELEVATION ON 00-G-003 FOR MORE INFORMATION
OPERABLE PARTITION, SEE SPECIFICATIONS FOR MORE DETAILS
PROVIDE MAP RAIL ON ALL WALLS IN THIS ROOM, SEE MOUNTING
HEIGHTS ELEVATION ON 00-G-003 FOR MORE INFORMATION
PROVIDE 1" POWDER COATED BLINDS ON INTERIOR SIDELITE, SEE FINISH
SCHEDULE FOR COLOR SPECIFICATIONS
APPLY PAINTED FRP BOARD ON ALL WALLS IN THIS ROOM, 4" A.F.F. TO 4’-0" H.
PAINT TO MATCH ADJACENT WALL
PROVIDE COAT HOOK IN SHOWN LOCATIONS, SEE
MOUNTING HEIGHTS ELEVATION ON 00-G-003 FOR
MORE INFORMATION
PROVIDE MARLITE BOARD FROM FLOOR TO CEILING AND THE
ENTIRE WIDTH OF THE WALL. BEHIND THE MARLITE BOARD
INSTALL GRADE 1 SELECT WOOD BLOCKING
TROPHY / DISPLAY CASES TO BE INSTALLED IN ALCOVE, SEE MILLWORK
SECTIONS / ELEVATIONS FOR MORE INFORMATION
MAILBOX SLOTS, SEE SPECIFICATIONS FOR MORE DETAILS
CLASS 5 SAFE (GFGI)
PROVIDE 8’x4’ MARKER BOARD WITH 1/2" ALUMINUM TRIM AND A 2" MAP RAIL
ON TOP AND A 2" TRAY ON BOTTOM, SEE MOUNTING HEIGHTS ELEVATION ON
00-G-003 FOR MORE INFORMATION. CENTER ON WALL
PROVIDE 4x3 TACKBOARD WITH 1/2" ALUMINUM TRIM, SEE MOUNTING HEIGHTS
ELEVATION ON 00-G-003 FOR MORE INFORMATION
ENCLOSED 6’x4’ BUILDING DIRECTORY BOARD, SEE MOUNTING HEIGHTS
ELEVATION ON 00-G-003 FOR MORE INFORMATION
’MINUTEMAN PLAQUE’ SUPPLIED BY THE GOVERN. AND INSTALLED BY
CONTRACTOR. PROVIDE ADDITIONAL WOOD BLOCKING FOR SUPPORT.
VIDEO TELECONFERENCING UNIT - (GFGI)
PROVIDE 6’X4’ ENCLOSED BUILDING BULLETIN BOARD WITH 1/2" ALUMINUM
FRAME, SEE MOUNTING HEIGHTS ELEVATION ON
00-G-003 FOR MORE INFORMATION
EST COMPRESSOR (GFGI)
8" x 8" ACCESS DOOR
KNOX BOX - 54" A.F.F.
FIRE ALARM CONTROL PANEL, SEE FIRE ALARM DRAWINGS FOR INFORMATION
NOT USED
SEMI-RECESSED FIRE EXTINGUISHER, SEE TYPICAL MOUNTING HEIGHTS FOR
MORE INFORMATION
FIRE EXTINGUISHER (BRACKET MOUNTED)
UNDERCOUNTER REFRIGERATOR PROVIDED BY OTHERS
OUTLINE OF RADON SUMP BELOW SLAB - SEE SHEET 00-A-522 FOR DETAILS
LOCATION OF 6" DIA. OF RADON SUMP VENT (V.T.R.)
/8
/4
6’-4"14’-4"
1’-4"
6’-8"29’-3"31’-9"3’-4"2’-8"
1’-8"
20’-6" 41’-2" TO GRID 6
17’-2"2’-6"4’-0"4’-0"4’-0"3’-8"5’-4"4’-0"5’-4"4’-0"4’-4"6’-4"4’-0"5’-4"4’-0"5’-4"
2’-11 1/4 "
9’-3 3/4 "12’-4 1/2 "7’-0 1/2 "4’-0"6’-0"4’-0"4’-4"
1’-8"
24’-0" TO GRID 6
/4
/4
/2
/2
5’-0" 15’-8 3/8 " 5’-0"
2’-3 1/2 "
14’-6 1/8 "
2’-3 1/2 "
26’-2"12’-8 1/2 "3’-6"
/2
/8
5’-0"5’-7 1/2 "16’-5 1/2 "14’-8"
5’-4"6’-4 1/2 "5’-4"5’-4"
/8
/8
3’-3 5/8 "5’-7 7/8 "
11’-4"
10"
6’-8"4’-11 1/8 "
2’-3 1/8 "
/8
/8
1 2 3 3.2 4 5
A
B
C
D
D.1
E
D.6
2.7
122A
ASSEMBLY
HALL / DRILL HALL
A
STAIR
119B
TER.
129A
DIST. LEARNING
102A
MAIL DISTRIBUTION
FAMILY SUPPORT
111A
CLASSROOM
111B
112A
112B
SIPRNET CAFE
TRNG AIDS
LOBBY
127A
WOMEN
106B
CORR
106C
106A
106E
106F
123B
CONTROL RM.
109A
LIBRARY
READING ROOM
109B
RAPIDS OFF
126B
MENS LOCKERS
127B
LOCKER
118B
ELEC
121B
MECH
FOOD STORAGE
JANITOR
ELEVATOR RM.
129B
REC/RET OFF
101A
FAC MANAGER
126A
MEN
122B
CHAIR STOR
100A
VESTIBULE
100B
VESTIBULE
106D
A
ELEVATOR
LRNG CTR
123C
CONTROL
ROOM STORAGE
123A
WEAPONS SIMULATOR
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS
OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,
FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,
SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.
5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE
SPACE ONLY.
7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.
8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.
File details come from the government source that posted it. Updated .