AF2AEE-1.PDF
PDF 2 MB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains a life safety plan drawing and specifications for building renovations. The project involves HVAC systems repairs to an existing training facility located at the Naval Air Station Joint Reserve Base Willow Grove in Horsham, Pennsylvania under Solicitation Number W912BU24R0001. The scope of work includes replacing air handling units, fans, ductwork, controls and other HVAC components. The facility is a three-story unprotected noncombustible structure with an automatic sprinkler system. Construction must meet the requirements for Type II-B construction and Use Group B occupancy.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-G-102
A2
SECOND FLOOR LIFE SAFETY PLAN - TRAINING BLDG
1/16" = 1’-0"
T R
A
IN
IN
G C
E N
T E
R S
E C
O N
D F
L O
O R L
IF
E S
A F
E T
Y P
L A
N
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\General\AFRC5500-G-102.dgn
9/11/2012
9:18:36 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-G
-1 .d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
PLAN
NORTH
USE GROUP B
1 HR FIRE BARRIER UL #U495
32’8’
SCALE:1/16"=1’-0"
0 16’
1 HR FIRE BARRIER UL #U495
1 HR FIRE BARRIER UL #U417
1 HR FIRE BARRIER UL #U495
107’
107’ 244’
FEC
FEC
FEC
FEC
FE
188’
FEC
150’
FEC
146’
FEC
FEC
FEC
FEC
SMOKE ENCLOSURE
SMOKE ENCLOSURE
SMOKE
ENCL.
SMOKE
ENCL.
SMOKE
ENCL. SMOKE
ENCL.
21 2.7 3 3.2 4 5 6 6.4 7 7.8 8 9 10
1 2 3 3.2 4 5 6 6.4 7 7.8 8 9 10
A
B
C
D
E
A
B
C
D
D.1
E
D.6
2.7
A
STAIR
230B
UC AREA
210A
UNIT COMMON
202A
ELEC
202B
ELEC
MECH
JANITOR
210G
STORAGE
TER.
210B
ADMIN COMMON
210F
BREAK / VENDING
210J
CLOSET
211A
DET 317 UE OFC
211B
DET 317 UE OFC
211C
DET 317 PS OFC
211D
DET 317 PS OFC
212A
DET 430 PS OFC
213A
157 UE OFFICE
213C
213D
157 PS OFFICE
213E
157 F/T OFFICE
213F
213G
213H
213I
213J
213K
213L
213M
213N
213O
213P
214A
DRT 733 F/T OFC
215A
367 F/T OFFICE
215B
367 UE OFFICE
215C
215D
215E
216A
TM26 150 PS OFC
217A
TM32 154 PS OFC
218A
TM32 154 PS OFC
219A
109 PS OFC
220C
338 UE OFFICE
220D
220E
338 F/T OFFICE
220F
220G
220H
220I
338 F/T OFC
220J
220K
220L
220M
F/T OFFICE
220N
F/T OFFICE
220O
338 PS OFFICE
220P
338 PS OFC
220Q
220R
220S
220T
338 PS OFFICE 220U
338 PS OFC
220V
220W
221A
TM8 153 PS OFC
222A
TM8 153 OFFICE
223A
TM1 153 UE OFFICE223B
TM1 153 UE OFFICE
223C
TM1 153 UE OFFICE
223D
TM8
153 PS OFC
224A
HQ 223 UE OFFICE
224B
HQ 223 F/T OFFICE
224C
224D
224E
225A
369 UE OFFICE
225B
369 F/T OFFICE
225C
369 F/T OFFICE
226A
427 F/T OFC
226B
427 PS OFC
226C
427 F/T OFC
227A
RSC 99 F/T OFC
227B
227C
B
STAIR
A
ELEVATOR
210H
201D
CORR
201B
201G
201F
201A
201H
201C
210I
210D
FACILITY STORAGE
210C
GENERAL SUPPORT
WOMEN
MEN
LOBBY
213B
220A
220B
EXIT EXIT LOCATION
EXIT SIGN
FIRE EXTINGUISHER (RECESSED WALL CABINET)
LEGEND
FIRE EXTINGUISHER (BRACKET MOUNTED)
CONSTRUCTION TYPE / USE GROUP / FIRE PROTECTION
CONSTRUCTION TYPE (IBC 2006 SECTION 602.2):
TYPE 2B - UNPROTECTED NONCOMBUSTIBLE
A3 ASSEMBLY (ACCESSORY USE; SECTION 508.3.1)
(FULLY SPRINKLED)
FIRE PROTECTION SYSTEM(S):
AUTOMATIC SPRINKLERS:
USE GROUP (IBC 2006):
BUILDING HEIGHT: (IBC 2006 TABLE 503)
ACTUAL HEIGHT:
ALLOWABLE HEIGHT: 3 STORY, 55 FEET
2 STORY, 42 FEET
ALLOWABLE AREA:
Tabular Area - per floor (Table 503)
Frontage Increase (506.2) = 75%
PLAN AREA DATA (S1 USE GOVERNS)
BUILDING & STRUCTURE ELEMENTS: (IBC 2006 TABLE 601
FIRE RESISTANCE RATINGS : (IBC CHAPTER 7)
COLUMNS
SHAFTS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
ELEVATOR ENCLOSURES
LOAD BEARING WALLS
HORIZONTAL EXIT
EXIT ENCLOSURES:
EXIT CORRIDORS
EXIT PASSAGEWAY
STAIR ENCLOSURES
1 HOUR
1 HOUR
1 HOUR
0 HOURS
0 HOURS*
0 HOURS
0 HOURS
0 HOURS
1 HOUR
2 HOUR
3 STORIES OR LESS: ALLOWABLE AREA - per floor
Sprinkler Increase (506.3) = 200%
S.F. AREA:
17,500
35,000
65,625
41,916ACTUAL AREA - per floor (1st floor worst case)
73,080ACTUAL AREA - Total Building
*NOTE: The rating of the building structure can not be less than the assembly it supports.
APPLICABLE CODES
TRAVEL DISTANCE:
TRAVEL DISTANCES (NFPA 101)
TRAVEL DISTANCE
B BUSINESS (SECTION 304)
NON-SEPARATED MIXED USE (SECTION 508.3.2)
ELEVATOR ROOM 2 HOUR
OCCUPANCY
ASSEMBLY
BUSINESS
STORAGE
250 FEET
300 FEET
400 FEET
DEAD ENDS:
DEAD END LENGTHOCCUPANCY
ASSEMBLY
BUSINESS
STORAGE
20 FEET
50 FEET
100 FEET
COMMON PATH OF TRAVEL:
COMMON PATHOCCUPANCY
ASSEMBLY (>50 OCCUPANTS)
BUSINESS
STORAGE
20 FEET
100 FEET
100 FEET
ASSEMBLY (<50 OCCUPANTS) 75 FEET
ALLOWABLE AREA - Total Building 131,250
S1 MODERATE HAZARD STORAGE (SECTION 311)
13,125
1 HOUR FIRE BARRIER - UL 495
2 HOUR FIRE BARRIER - UL417, UL495
OCCUPANCY:
OFFICE
LOCKER ROOM
MECH/ELEC/STORAGE
TOTAL
AREA:
3,243
2,588
1,165
2,332
9,428
ROOMS W/ INDIVIDUAL
EXITS
TOTAL
LOAD
FACTOR:
OCCUPANT
LOAD:
20 SF/PERSON
100 SF/PERSON
50 SF/PERSON
300 SF/PERSON
OCCUPANCY:
WEAPONS SIMULATOR
ASSEMBLY HALL
ELECTRICAL ROOM
MECHANICAL ROOM
MECHANICAL ROOM
ELECTRICAL ROOM
AREA:
LOAD
FACTOR:
OCCUPANT
LOAD:
1,480 20 SF/PERSON 74
520 300 SF/PERSON 2
1,527 300 SF/PERSON 6
96 300 SF/PERSON 1
1,530 20 SF/PERSON 77
3,652 15 SF/PERSON 243
161 300 SF/PERSON 1
168 300 SF/PERSON 1
15,700 300 SF/PERSON 52
OCCUPANT LOAD (NFPA 101 TABLE 7.3.1.2)
EF
TOTAL
AREA:
LOAD
FACTOR:
OCCUPANT
LOAD:
OCCUPANCY:
2,995 300 SF/PERSON 7MECH/ELEC/STORAGE
20,849 100 SF/PERSON 192OFFICE
TOTAL 238
EXIT CAPACITY (NFPA 101 TABLE 7.3.3.1)
FIRE AREA: SINGLE
CLEAR
WIDTH:
CAPACITY
FACTOR:
EXIT
CAPACITY:EXIT LOCATION:
136 INCHES 0.2 IN/PERSON
TYPICAL DOUBLE
DOORS (2) 680
CLEAR
WIDTH:
CAPACITY
FACTOR:
EXIT
CAPACITY:EXIT LOCATION:
68 INCHES 0.2 IN/PERSON
68 INCHES 0.2 IN/PERSON
136 INCHES 0.2 IN/PERSON 680
68 INCHES 0.2 IN/PERSON 340
TOTAL 3,220
CLEAR
WIDTH:
CAPACITY
FACTOR:
EXIT
CAPACITY:
EXIT LOCATION:
60 INCHES 0.3 IN/PERSONSTAIR A
46 INCHES 0.3 IN/PERSONSTAIR B
TOTAL
MIN. NUMBER OF EXITS: <500 OCCUPANTS = 2 (NFPA 7.4.1.2)
MIN. NUMBER OF EXITS: 500 - 1000 OCCUPANTS = 3 (NFPA 7.4.1.2)
UNIT STORAGE
WEAPONS SIMULATOR
MECHANICAL ROOM
MECHANICAL ROOM
EF
ASSEMBLY HALL
ELECTRICAL ROOM
ELECTRICAL ROOM
UNIT STORAGE
68 INCHES 0.2 IN/PERSON 340
68 INCHES 0.2 IN/PERSON 340
68 INCHES 0.2 IN/PERSON 340
32 INCHES 0.2 IN/PERSON 160
68 INCHES 0.2 IN/PERSON 340
FIRST FLOOR OCCUPANT LOAD
FIRST FLOOR OCCUPANT LOAD OF ROOMS W/ INDIVIDUAL EXITS
SECOND FLOOR OCCUPANT LOAD
EXIT CAPACITY OF ROOMS W/ INDIVIDUAL EXITS
FIRST FLOOR EXIT CAPACITY
SECOND FLOOR EXIT CAPACITY
CODE / LIFESAFETY DATA - TRAINING BUILDING
CLASSROOM/LEARNING
STAIRS FROM SECOND
FE
FEC
BREAK AREA 279 15 SF/PERSON 19
CLASSROOMS/LEARNING (2)
CLASSROOM/LEARNING
EXIT LOAD (OCCUPANTS)
TRAVEL DISTANCE
OCCUPANT LOAD25
UFC 1-200-01; GENERAL BUILDING REQUIREMENTS
UFC 3-600-01; FIRE PROTECTION ENGINEERING FOR FACILITIES
UFC 4-010-01; MINIMUM ANTI TERRORISM STANDARDS
IBC 2006; INTERNATIONAL BUILDING CODE
NFPA 101 2009; LIFE SAFETY CODE
ADAAG; ADA ACCESSIBILITY GUIDELINES
INCIDENTAL USE: STORAGE ROOMS > 100 S.F., BOILER ROOMS, REFRIGERATION
COMPARTMENT ROOMS AND MECHANICAL ROOMS MAY BE EXCUSED WITH SMOKE
PARTITIONS IF BUILDING IS FULLY SPRINKLED
SMOKE BARRIER