AF7BD0-1.PDF
PDF 760 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains architectural drawings and specifications for proposed masonry control joint locations on an Army Reserve Training Center located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The drawings depict the south and west exterior elevations of the building and include details for masonry control joints, joints at loose lintels, and waterproofing requirements. Control joint locations are shown along grid lines A and B with notes specifying alignments with windows and doors and sealant color transitions. The related federal contract opportunity is solicitation number W912BU24R0001 from the Department of the Army Corps of Engineers Engineering District Philadelphia for HVAC system repairs at the PA 206 facility in Horsham.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-2031/8" = 1’ 0" A4
SOUTH ELEVATION
1/8" = 1’ 0" C4
WEST ELEVATION
D4
PLAN DETAIL @ MASONRY CONTROL JOINT (TYP)
3" = 1’ 0"3" = 1’ 0"
D3
DETAIL @ MASONRY CONTROL JOINT WITH LINTEL
SCALE: 3"=1’
3" 6" 9" 12"0
SCALE: 3"=1’
3" 6" 9" 12"
AS-BUILT
O M
S A
M S
A E
X T
E R
IO
R E
L E
V A
T
IO
N S
S
O U
T H A
N D W
E S
T M
A S
O N
R Y C
O N
T R
O L J
O
IN
T L
O C
A T
IO
N S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-203.dgn
9/11/2012
9:33:24 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -2
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
EDC.5CB.5BA
1 2 3 4 51.5
12’-8"6’-4"11’-4"16’-8"13’-4"16’-8"11’-4"6’-4"12’-8"
3’-8"12’-0"16’-0"16’-0"18’-8"18’-0"6’-4"16’-0"4’-0"16’-0"4’-0"16’-0"4’-0"16’-0"6’-4"
MASONRY CONTROL JOINT LOCATION SEE DETAIL D4 ON SHEET 10-A-203
CONTROL JOINT LOCATIONS ALONG GRID LINE "B" CONTROL JOINT LOCATIONS ALONG GRID LINE "A"
TYP.
TYP.
1. ALIGN CONTROL JOINTS WITH WINDOW AND DOOR OPENINGS AS SHOWN
2. SEE DETAIL D3 ON SHEET 10-A-203 FOR CONTROL JOINT CONDITION AT
LOOSE LINTELS
3. PROVIDE SEALANT COLOR TRANSITIONS TO MATCH ADJACENT BRICK
OR CMU BLOCK ALONG LENGTH OF MASONRY CONTROL JOINT.
4. SEE DETAIL C3 ON SHEET 10-A-531 FOR WATERPROOFING CONDITION AT
LOOSE LINTELS AND MASONRY TIES
A B B.5 C C.5 D E
1 2 3 4 51.5
BACKER ROD AND SEALANT
COMPRESSIBLE MATERIAL
FLASHING USED FOR
SLIP PLANE
FLASHING
CONTROL JOINT - BACKER ROD AND SEALANT
WINDOW OR DOOR FRAME
SCHEDULED BRICK OR CMU BLOCK
GALVANIZED STEEL LINTEL
BACKER ROD AND SEALANT
SCHEDULED BRICK
OR CMU BLOCK
BRICK TIE
2" RIGID INSULATION
A.M.B.S.
BATT INSUL. (R-19)
6" MTL. STUD
5/8" GYP. BD.
5/8" EXTERIOR GYP. SHEATHING
8’0 4’ 16’
SCALE:1/8"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
File details come from the government source that posted it. Updated .