This document package includes architectural drawings and plans for renovations to restrooms and locker rooms at the Army Reserve Training Center in Willow Grove, Pennsylvania, as well as a related federal contract opportunity notice.
The architectural drawings show layouts and details for enlarged first and second floor restroom plans, including locations and dimensions of fixtures, partitions, lockers, and other features. The drawings also provide general notes specifying construction requirements such as partition types and heights. Meanwhile, the federal contract opportunity seeks proposals for HVAC system repairs at the PA 206 Horsham facility. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Philadelphia as a special notice. Interested offerors should reference solicitation number W912BU24R0001 for additional details on response dates and other contractual terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-401 1/4" = 1’-0"
A4 1/4" = 1’-0"
A1 ENLARGED SECOND FLOOR RESTROOM PLAN ENLARGED FIRST FLOOR RESTROOM AND LOCKER PLAN
T R
A
IN
IN
G C
E N
T E
R E
N L
A R
G E
D F
L O
O R P
L A
N S
1/4" = 1’-0" D1
ENLARGED FIRST FLOOR MAIL DISTRIBUTION PLAN
REVISED AS-BUILT
F
IE
L D C
O N
D
IT
IO
N
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-401.dgn
9/11/2012
9:23:45 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
4’ 8’0 2’
SCALE:1/4"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -4
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
00-A-411
00-A-411 00-A-411
00-A-411
00-A-411
00-A-411
3’-4"3’-4"3’-4"5’-9 1/4 "
9’-6 1/4 "
3’-8"
3’-4" 3’-4"
15’-9 1/4 "2’-1 7/8 " 3’-2"
2’-9" 11’-5 1/8 "2’-4"11’-1 1/8 "
2’-10"
B
CC
2K
T
SW
3A
T
SW
1A
U
1A
U
2A
T
SW
2A
T
SW
1’-4" 2’-10"
A
A
2’-4"11’-6"2’-9"
/4
/8
/8
/8
/4
/2
/8
/4
/8
7’-2"
27’-2 1/8 "2’-2"
B1
D2
B2 / C2
A3
A4
B4 / C4
D2
D4
00-A-411A1
D4 00-A-412
1A
U
1A
U
A
C
B
B
A
D
C
D
CCCC
D
CC
/8
1A
U
1A
U
3A
S
SW
5’-1 1/2 " 3’-1" 3’-1" 3’-1" 3’-1"
/8
/4
/8
/8
5’-4 7/8 "3’-4"20’-0 1/8 "4’-9" 5’-11"
TYP.
TYP.
TYP.
2A
U
1A
U
1A
U
/8
16’-4 7/8 " 2’-4 1/4 " 3’-10 3/4 "
/8
4’-0"
4’-10 1/8 "
E E E
E
A
D D D
CC
D
C
C C
/4
C
E E
ALIGN
A L
IG
N
A L
IG
N A
L
IG
N
A L
IG
N
2K
T
SW
2D
S
SW
SW
2E
S
2F
S
SW
F H
F
E E
H
EEE
F H
D
G
J J
J
J J
J
J
J
K
K
L
J J J J
G
E
FEEEE
H
K
/2
210F
BREAK / VENDING
WOMEN
MEN
JANITOR
126B
MENS LOCKERS
FOOD STORAGE
126A
MEN
127A
WOMEN
127B
LOCKER
JANITOR
K
2F
S
SW
6 6
A L
IG
N
18 LOCKERS @ 18’-0"
18 LOCKERS @ 18’-0"
L
O C
K E
R S
PLAN
NORTH
2A
U
SW
SW
2A
U SW
21 LOCKERS @ 21’-0"
8 1/4 "
10’-9 1/8 "3’-3 5/8 "
2A
T
SW
2A
T
SW
2E
S
SW
2A
T
SW
CL CL CL
CL
CLCLCL
CL
SW
2A
T
SW
3’-9 5/8 "3’-9 5/8 "EQ. EQ.
1’-9"
A L
IG
N
EQ.2’-9"2’-8"2’-9"EQ.
LC LC
A L
IG
N
/8
4’-0"
CL
CL
CL CL CL
CL CL
1A
U
2C
S
SW
2J
S
SW
2A
U
SW
CL LC LC LC LC LC
SW
SW
2A
U
SW
2A
U
SW
CL CL CL CL CL
2A
U
SW
1A
U
2A
U
SW
2A
U
SW
SW
2A
U
SW
2A
U
L
5’-0" 4’-9 1/8 " 5’-1 3/4 " CLEAR 9 1/4 "
5’-1 3/4 " CLEAR
2A
U
C
L
TYP.
L
L
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
C5
00-A-511
1 2
D.1
D
4 3/4 "4’-7 1/8 "8’-1" 8 7/8 "
/8
10-A-410
A1
1’-4 1/8 "1’-0"3’-3"
3A
T
SW
/4
/4
2’-1 1/8 "3’-4"
3A
T
SW
5’-0"
106B
CORR
Q1Q1Q2Q4
Q4
Q4
Q3 Q3
TYP. TYP.
2’-10 3/4 "
EQ 2’-9" 2’-9" 2’-9" 2’-9" 2’-9" EQ
2A
U
SW
2A
U
SW
2A
U
SW
2’-10 3/4 " 2’-10 3/4 " EQ 2’-11" 2’-11" 2’-11" 2’-11" EQ
2’-10"EQ EQ
EQEQ
2’-10 3/4 " 2’-10 3/4 "
2’-5 1/4 "
/8
EQ EQ6’-4 1/4 "
5’-3" 4’-6"
1’-10 1/4 "
9’-3 7/8 " 17’-6" 5’-10" 5’-0 1/8 "
/4
/4
/4
/4
/4
/8
1’-1 7/8 "
5’-2 1/2 " 3’-1" 3’-1" 3’-1" 1’-5 3/4 "
16’-4 3/8 " 1’-6"
TYP.
TYP.
TYP.
TYP.
2’-10 3/4 " 2’-10 3/4 " 2’-10 3/4 " 2’-10 3/4 " 2’-10 3/4 " 2’-10 3/4 " 2’-10 3/4 "
L 3 2
TYP.
3A
S
SW
2K
U SW
DN
M
B
C
B
J
M
N
LOCKER ROOM BENCHES
FIBERGLASS SHOWER SURROUND TO BE APPLIED TO ALL GYP. BOARD
SURFACES IN THE SHOWER AREA, SEE INTERIOR ELEVATIONS FOR MORE
INFORMATION
SHOWER CURTAIN AND ROD TO BE MOUNTED AT 6’-0" A.F.F.
ELECTRIC DRINKING FOUNTAIN
TOILET PARTITION
MOP SINK
STAINLESS STEEL REFRIGERATOR
PROVIDE 8’W x 4’H TACKBOARD WITH 1/4" ALUMINUM TRIM, SEE MOUNTING HEIGHTS ELEVATION ON 00-A-412 FOR
MORE INFORMATION
VENDING MACHINES PROVIDED BY OTHERS
MICROWAVE PROVIDED BY OTHERS
SEMI-RECESSED FIRE EXTINGUISHER CABINET
1 TIER METAL LOCKER 1’-0"W x 1’-6"D x 7’-0"H
2 TIER METAL LOCKER 1’-0"W x 1’-6"D x 7’-0"H (INDICATED WITH A HATCH)
FOODSERVICE EQUIPMENT - SEE SPECIFICATIONS
102A
MAIL DISTRIBUTION
00-A-412
00-A-412
00-A-412
D2
A2
B2 / C2
A4
B4 / C4
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND
00-A-500.
8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.
4’ 8’0 2’
SCALE:1/4"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
TOILET ACCESSORY LEGEND
File details come from the government source that posted it. Updated .