AFDA0C-1.PDF

PDF 2 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains construction drawings for stair details at an Army Reserve Training Center. The drawings show steel stringers, pan treads and risers, wood and steel handrails, and concrete landings for two staircases (Stairs A and B). Dimensions and materials are provided for stair components. Notes specify requirements like fireproofing, slip tracks for movement, and tile joints at slab edges. The related federal contract opportunity is a special notice from the US Army Corps of Engineers Philadelphia District seeking repairs to HVAC systems at the PA 206 Horsham facility.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-803 A4

1" = 1’-0"

STAIR DETAIL - INTERMEDIATE LANDING (STAIR "A")

1" = 1’-0" C4

STAIR DETAIL - TOP LANDING (STAIR "A")

STAIR DETAIL - INTERMEDIATE LANDING (STAIR "B")

1" = 1’-0"

A2

STAIR DETAIL - TOP LANDING (STAIR "B")

C2

1" = 1’-0" C1

1" = 1’-0"

DETAIL - TOP LANDING (STAIR "A")

DETAIL - TOP LANDING (STAIR "A")

1" = 1’-0"

A1

SCALE:1"=1’

1’ 2’0

SCALE:1"=1’

1’ 2’0

SCALE:1"=1’

1’ 2’

SCALE:1"=1’

1’ 2’ 0

SCALE:1"=1’

1’ 2’ 0

SCALE:1"=1’

1’ 2’

AS-BUILT

T R

A

IN

IN

G C

E N

T E

R S

T A

IR

D

E T

A

IL

S

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-803.dgn

9/11/2012

9:27:20 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -8

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

LC

SEE PLAN

EQUALEQUAL3 3/4 "

1"

1"

" 3

3 3/4 "

3 3/4 "

3 3/4 "EQEQ

1"

1"

SEE PLAN

3 3/4 "SEE PLAN

109’-0"

SOFFIT

109’-0"

SOFFIT

114’-0"

FINISH FLOOR

/2

3 3/4 "

00-A-804

C3

C4

D4

D3

00-A-804

OPP

D2

00-A-804

OPP

D2

CAP WALL ENDS OF GUARD

& HAND RAILS, TYP.

1 1/2" STL

HANDRAIL

1 1/2" SQUARE STL

GUARDRAIL

1/2" X 1/2" STL.

BARS

1 1/2" STL

HANDRAIL

5/8" x 1 1/2" STL BAR

FIRE PROOFING

STL. PLATE BY STAIR MFR.

1 1/2" SQUARE STL.

GUARDRAIL & POST

STL. HANDRAIL

PROVIDE SLIP TRACK TO

ALLOW FOR

MOVEMENT/DEFLECTION,

TYP

STL. ROD BY STAIR MFR.

1/2" x 1/2" STL. BARS

5/8" x 1 1/2" STL. BAR

BRACKET ANGLE WELDED TO

STRINGER BY STAIR MFR.

STL. CLOSURE PLATE

CONC. LANDING

CONC. FILLED STL. PAN

RISERS & TREADS

STL. CLIP ANGLE BY STAIR MFR.

STL. PLATE BY STAIR MFR.

FIRE PROOFING

PROVIDE SLIP TRACK TO

ALLOW FOR

MOVEMENT/DEFLECTION,

TYP

STL. ROD BY STAIR MFR.

BRACKET ANGLE WELDED TO

STRINGER BY STAIR MFR.

1 1/2" DIA. WOOD HAND

RAIL

(STAINED)

2" DIA. WOOD TOP RAIL

(STAINED)

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

WELDED TO STRINGER

1/2" THK. PANEL

INSERT

STL. CLOSURE PLATE

CONC. LANDING

(TILED)

STL. CHANNEL TO FIT

BETWEEN STRINGER &

GYP. PARTITION.

CONCRETE LANDING,

BEYOND.

CONCRETE LANDING, BEYOND.

STL. CHANNEL TO FIT BETWEEN

STRINGER & GYP. PARTITION.

1 1/2" DIA. WOOD HAND

RAIL (STAINED)

STL.

STRINGER.

STL. STRINGER.

SCHEDULED FURRING

CONC. FILLED STL.

PAN RISERS &

TREADS.

SCHEDULED PARTITION

HOLD TIGHT TO UNDERSIDE

OF STL. STRINGER

BACKER ROD AND SEALANT

1/2" THK. PANEL INSERT

CONC. FILLED STL. PAN

RISERS & TREADS. (TILED)

CONC. FILLED STL. PAN

RISERS & TREADS. (TILED)

PROVIDE TILE JOINT

AT EDGE OF SLAB

GYP. BD. SOFFIT

STL. STRINGER

1/2" THK. PANEL

INSERT

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

WELDED TO STRINGER

1 1/2" DIA. WOOD HAND

RAIL (STAINED)

2" DIA. WOOD TOP RAIL

(STAINED)

2" DIA. WOOD TOP RAIL

(STAINED)

STL. STRINGER (PAINT)

BACKER ROD AND SEALANT

2" DIA. WOOD TOP RAIL

(STAINED)

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

1 1/2" DIA. WOOD HAND

RAIL (STAINED)

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

WELDED TO STRINGER

1/2" THK. PANEL

INSERT

3/8" X 1 1/2" STL/. PLATE

(PAINTED)

STL. STRINGER (PAINT)

CONC. LANDING (TILED)

RECESS 2ND FLOOR LANDING

CONC. POUR TO ACCEPT FLUSH

TILE FIT

RECESS 2ND FLOOR LANDING

CONC. POUR TO ACCEPT FLUSH

TILE FIT

File details come from the government source that posted it. Updated .