AF85D7-1.PDF

PDF 463 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This file contains architectural drawings and plans for stairwell and ceiling improvements at the Army Reserve Training Center in Willow Grove, Pennsylvania. The drawings depict details for Stair B, including section views, floor plans on the first and second levels, and notes specifying fire rated ceiling assemblies. The related federal contract opportunity is a special notice from the U.S. Army Corps of Engineers Philadelphia District seeking proposals to repair HVAC systems at the PA 206 facility in Horsham, Pennsylvania. No additional details are provided on the requirements, response timeline, or anticipated award date for the HVAC repair work.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-802

A5 1/4" = 1’-0"

A1 1/2" = 1’-0"

STAIR B - SECTION

C5 1/4" = 1’-0"

STAIR B - SECOND FLOOR PLAN

STAIR B - FIRST FLOOR PLAN T

R

A

IN

IN

G C

E N

T E

R E

N L

A R

G E

D P

L A

N A

N D S

E C

T

IO

N S

T A

IR

B

4’ 8’0 2’

SCALE:1/4"=1’

PLAN

NORTH

4’ 8’0 2’

SCALE:1/4"=1’

PLAN

NORTH

2’ 4’0 1’

SCALE:1/2"=1’-0"

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-802.dgn

9/11/2012

9:27:14 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -8

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

B1.1

B1.2

B2

E

E

1’-5 1/4 "

/4

T

R E

A D

S

/8

/8

5 3/8 "9’-4 1/8 "

11"

2E

S

1A

S

A1

A1

2E

S

1A

S

2E

S

2E

S

8’-5 1/8 " 11"

/8

/2

6 1/2 "

3’-11 1/4 " 3’-11 1/4 "

/2

/8

T

R E

A D

S

4’-5 7/8 " 3’-11 1/4 "

STAIR

STAIR

SW SW

SW

SW

SW

SW

100’-0"

1ST FLOOR

114’-0"

2ND FLOOR

107’-0"

INTERMEDIATE LANDING

R

IS

E R

S

E A

R

IS

E R

S

E A

E

00-A-804

A5

C5

00-A-803

A2

00-A-803

C2

122’-8"

RATED STAIRWELL CEILING

B2

A2

FIRE RATED CEILING ASSEMBLY

REFER TO NER-258

File details come from the government source that posted it. Updated .