AF1533-1.PDF

PDF 1 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains elevator details and specifications for the PA 206 Horsham HVAC Systems Repairs project. The project involves repairs to HVAC systems at the Army Reserve Training Center in Horsham, Pennsylvania. Elevator details include shaftwall construction, pit ladder details, guide rail details, and sill details. Specifications require fire rated partitions, shaft wall construction of metal studs and two layers of 5/8 inch type X gypsum board. The opportunity is a special notice from the Department of the Army Corps of Engineers Engineering District Philadelphia solicitation number W912BU24R0001 for HVAC system repairs. No response or award dates are included.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-812 A5

1 1/2" = 1’-0" A4

1 1/2" = 1’-0" A3

1 1/2" = 1’-0"

C5 1 1/2" = 1’-0"

C4 1 1/2" = 1’-0"

C3 1 1/2" = 1’-0"

ELEVATOR DETAIL @ SHAFTWALLELEVATOR PIT DETAIL @ SILLPIT LADDER DETAIL

ELEVATOR SHAFT DETAILELEVATOR SILL DETAILGUIDE RAIL DETAIL

1’ 2’0 6"

SCALE:1-1/2"=1’

1’ 2’0 6"

SCALE:1-1/2"=1’

1’ 2’0 6"

SCALE:1-1/2"=1’

1’ 2’0 6"

SCALE:1-1/2"=1’

1’ 2’0 6"

SCALE:1-1/2"=1’

1’ 2’0 6"

SCALE:1-1/2"=1’

A2

RATED CEILING DETAIL

3" = 1’-0" 0

SCALE: 3"=1’

3" 6" 9" 12"

AS-BUILT

T R

A

IN

IN

G C

E N

T E

R E

L E

V A

T O

R D

E T

A

IL

S

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-812.dgn

9/11/2012

9:27:51 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -8

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

CL

CL

CL CL

CL

CL

SEE PLAN

1 1/2 " E.O.S.

SEE PLAN

1 1/2 " E.O.S.

SEE PLAN

SEE PLAN

FIRE RATED PARTITION - SEE

PLAN FOR SPECIFIC P-TYPE

AND REQ’D UL ASSEMBLY

CONCRETE SLAB

CONCRETE FOUNDATION/

PIT WALL

PROVIDE

BENTONITE

WATERSTOP, TYP.

PROVIDE

BENTONITE

WATERSTOP, TYP.

CONCRETE FOUNDATION / PIT

WALL

CONCRETE SLAB

STEEL SILL ANGLE.

ASSEMBLY BY

ELEVATOR

CONTRACTOR

NON-SHRINK

GROUT

ELEVATOR FRAME

BEYOND

ELEVATOR DOOR

STEEL CLIP ANGLE

& ANCHORS-

SEE STRUCTURAL

5/8" TYPE "X" GYP. BD. ON

MTL. STUDS @ 16" O.C. -

SEAL TO DECKING TO

MAINTAIN FIRE RATING

(HOLD TIGHT)

FIRE PROOFING-

REFER TO RATED STRUCT

PLANS

STEEL BEAM.-

SEE STRUCTURAL

PROVIDE 1" GYP. BD.

SHAFT LINER AS REQ’D

BY LOCAL AUTHORITIES

CONCRETE FLOOR

SLAB-

SEE STRUCTURAL

STEEL EDGE ANGLE-

SEE STRUCTURAL

SEAL PARTITION TO SLAB-

AIR TIGHT

FIRE RATED PARTITION - SEE

PLAN FOR SPECIFIC P-TYPE AND

REQ’D UL ASSEMBLY

5/8" TYPE "X" GYP. BD. ON

MTL. STUDS @ 16" O.C. -

SEAL TO DECKING TO

MAINTAIN FIRE RATING.

(HOLD TIGHT.)

FIRE PROOFING. REFER TO

RATED STRUCT PLANS

STEEL BEAM-

SEE STRUCTURAL

CONCRETE FLOOR

SLAB-

SEE STRUCTURAL

STEEL EDGE ANGLE-

SEE STRUCTURAL

NON-SHRINK

GROUT

ELEVATOR FRAME

BEYOND

ELEVATOR DOOR

CONCRETE FLOOR

SLAB.

RE: STRUC.

3/8" x 2 1/2" x 6" BENT

PLATE W/ (3) LEGS,

PAINT, TYP.

RADIUSED TOP EDGE

OF RAILS. PAINTED.

3/8" x 2 1/2" STEEL

BAR RAILS. PAINTED.

(WELDED TO BENT

PLATES)

FINISHED FLOORING

-SEE FINISH PLAN

FINISHED FLOORING

-SEE FINISH PLAN

FIRE RATED PARTITION - SEE

PLAN FOR SPECIFIC P-TYPE

AND REQ’D UL ASSEMBLY

BASE PLATE -

SEE

STRUCTURAL

STEEL TUBE SUPPORT

GUIDE RAIL -

SEE STRUCTURAL

EDGE OF PIT WALL

BELOW (@ 1ST FLOOR)

LAMINATE 1" SHAFT

LINER OVER EXPOSED

TUBE STEEL (EXTEND

PAST TUBE 2" EA. SIDE)

ELEVATOR GUIDE

RAIL BY ELEVATOR

CONTRACTOR

ELEVATOR

EDGE OF SLAB BELOW

(@ 2ND FLOOR.)

STEEL TUBE TO

SUPPORT ELEVATOR

GUIDE RAIL - SEE

STRUCTURAL

STEEL TUBE TO

SUPPORT ELEVATOR

GUIDE RAIL - SEE

STRUCTURAL

FIRE RATED PARTITION - SEE PLAN

FOR SPECIFIC P-TYPE AND REQ’D

UL ASSEMBLY

STEEL TUBE TO

SUPPORT ELEVATOR

GUIDE RAIL - SEE

STRUCTURAL

SHAFTWALL

STUD (C-H

STUDS, TYP.)

GUIDE RAIL BRACKET

BY ELEVATOR

CONTRACTOR

WATERPROOFING

MEMBRANE- SEE SPEC

WATERPROOFING

MEMBRANE-

SEE SPEC

/4

R

U N

G S /4

O .C

4 1/2" MIN.

3/8" x 2 1/2" BENT

PLATE

1" DIA. STEEL RUNGS

W/ TEXTURED

SURFACE TYP.

PAINTED.

( WELD TO RAILS)

6" SHAFT WALL

FRAMING

SCHEDULED PARTITION

W/ SOUND ATTENUATING

INSULATION

SOUND ATTENUATING

INSULATION

1" SHAFT LINER

2 LAYERS

5/8" TYPE X GYP BD

1" SHAFT LINER

File details come from the government source that posted it. Updated .