AF4200-1.PDF
PDF 555 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains a millwork detail drawing and related federal contract opportunity notice. The millwork detail drawing provides specifications for interior construction elements at the Army Reserve Training Center in Horsham, Pennsylvania, including display case dimensions and materials, mailboxes, and partition and ceiling placements. The related opportunity notice is for HVAC system repairs at the PA 206 facility in Horsham under solicitation number W912BU24R0001, issued by the U.S. Army Corps of Engineers Philadelphia District as a special notice. The notice involves repair work but provides no further details on requirements, response timing, or award information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-542A4 1 1/2" = 1’-0"
MILLWORK DETAIL
A3
1 1/2" = 1’-0"
MILLWORK DETAIL
1’ 2’0 6"
SCALE:1-1/2"=1’
1’ 2’0 6"
SCALE:1-1/2"=1’
AS-BUILT
T R
A
IN
IN
G C
E N
T E
R
IN
T E
R
IO
R D
E T
A
IL
S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-542.dgn
9/11/2012
9:26:14 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -5
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
/8 R .O (V
E R
IF
Y W
IT
H M
A N
U F
A C
T U
R E
R
1’-5" R.O.
(VERIFY WITH MANUFACTURER)
2’-0" R.O.
/8 R .O
PROVIDE KICKERS AS REQUIRED
SCHEDULED CEILING
SCHEDULED PARTITION
BOX BEAM HEADER
PROVIDE ELECTRIC FOR DISPLAY
CASE LIGHTING
DISPLAY CASE WITH SLIDING
GLASS DOORS AND ADJ. GLASS
SHELVING
(SEE SPECIFICATIONS)
3/4" FIRE RETARDANT PLYWOOD
BASE SECURED
TO MTL. FRAMING
SCHEDULED BASE SCHEDULED BASE
3/4" FIRE RETARDANT PLYWOOD
BASE SECURED
TO MTL. FRAMING
9 DOOR HORIZONTAL MAILBOX
UNIT
(SEE SPECIFICATION)
BOX BEAM HEADER
PROVIDE KICKERS AS REQUIRED
SCHEDULED PARTITION
SCHEDULED CEILING
File details come from the government source that posted it. Updated .