AF377B-1.PDF
PDF 845 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This reflected ceiling plan document details the layout and specifications for ceiling systems in the Army Reserve Training Center and OMS/AMSA buildings at Willow Grove Naval Air Station in Horsham, Pennsylvania. Key details include ceiling heights of 8'-8" throughout both buildings, locations of lighting fixtures, sprinkler heads, projection screens, access panels and other ceiling elements. The document provides ceiling notes specifying finish materials, construction requirements, and references related mechanical, electrical and fire protection drawings.
The related federal contract opportunity is a special notice for HVAC system repairs at the PA 206 Horsham facility. The solicitation is issued by the Department of the Army Corps of Engineers Philadelphia District and seeks contractors to perform repairs to the HVAC systems at the specified location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10-A-113
1/8" = 1’ 0" A4
REFLECTED CEILING PLAN - EAST
O M
S A
M S
A R
E F
L E
C T
E D C
E
IL
IN
G P
L A
N E
A S
T
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-113.dgn
5/30/2013
4:41:59 PM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
GENERAL NOTES
KEY PLAN
KEY NOTES
GRAPHIC SCALE
8’0 4’ 16’
SCALE:1/8"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -1
.d g n
/3
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
AMSA
CNTL WASTE STOR
155B
AMS TOOL ROOM
155A
AMS PARTS ROOM
140D
VESTIBULE
AMSA FLAM STOR
LIBRARY
MECHANICAL
ELECTRICAL
OMS
CNTL WASTE STOR
143B
F/T OFFICE
143C
F/T OFFICE
143A
OMS SHOP OFFICE
AMSA CLASS
BREAK ROOM
AMSA BATTERY ROOM
AMSA SHOP OFFICE
ELEC COMMO
TR.
140C
VESTIBULE
150C
ALCOVE
150B
EQUIP ALCOVE
145B
OMS TOOL & PARTS
145A
OMS STORAGE
153B
MENS LOCKERS
JANITOR
153A
MENS
TLT / SHOWER
154B
WOMENS LOCKERS
154A
WOMENS
TLT / SHOWER
140B
CORRIDOR
140A
CORRIDOR
OMS FLAM STOR
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
O.T.S.
8’-8"
O.T.S.
O.T.S.
8’-0"
8’-0"
8’-8"
8’-0"
8’-0"
M A
T C
H L
IN
E
A
-A -1
8’-0"
8’-0"
8’-8"
8’-8"
PLAN
NORTH
OVERHEAD POWERED PROJECTION SCREEN
ROOF RIDGE LINE FROM ABOVE
OVERHEAD DOOR TRACK
CEILING CONTROL JOINT, SEE 10-A-501 FOR MORE INFORMATION
3 4 5
A
B
B.5
C
C.5
D
E
TC
S
S
S
S
S
S
S
S
FACP F
F
F
P
P
P
P
P
P
P
P P T N
A C
P
P
CA
C A
CA
C A
C
A
CA
CA
C A
C
A
CA
C
A
C
A
C
A
S
S
S
S
S
C A
S
4WZAM
4WZAM
FF
C
A
F
CA
S
F
P
S
S
S
FF
REFLECTED CEILING LEGEND
8’-8"
R
CEILING TAG
PROJECTION SCREEN
CAN LIGHT
SUSPENDED LIGHT
FIXTURE
SURFACE MOUNTED
LIGHT FIXTURE
UPRIGHT
SPRINKLER
HEAD
SPRINKLER
HEAD
LAY IN
LIGHT
FIXTURE
RETURN/
EXHAUST
SUPPLY
PROJECTOR
ACOUSTICAL
CEILING TILE
GYP. BOARD
CEILING
SEE FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR FURTHER INFORMATION
1. ALL CEILINGS ON THE FIRST FLOOR OF THE TRAINING BUILDING TO
BE 8’-8" A.F.F., U.N.O.
2. ALL CEILINGS ON THE SECOND FLOOR OF THE TRAINING BUILDING
TO BE 8’-8" A.F.F., U.N.O.
3. ALL CEILINGS IN THE OMS / AMSA BUILDING TO BE 8’-8" A.F.F.,
U.N.O.
4. REFER TO THE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE
LIGHTING AND DIFFUSER LAYOUT.
5. ALL BULKHEADS ARE TO BE TYPE 2A / T, SEE REFLECTED CEILING
PLANS FOR HEIGHTS.
6. PROJECTION SCREENS AND PROJECTORS ARE SHOWN FOR
LOCATION SUGGESTION ONLY, SEE ELECTRICAL DRAWINGS FOR
FINAL LOCATIONS.
7. ALL CEILINGS NOTED AS O.T.S. (OPEN TO STRUCTURE) SHALL BE PAINTED
File details come from the government source that posted it. Updated .