AF54B2-1.PDF

PDF 558 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document package includes architectural drawings and specifications for elevator modernization work, along with details of a related federal contract opportunity. The drawings show first and second floor plans, sections and details for elevator replacement at the Army Reserve Training Center in Horsham, Pennsylvania. Specifications reference fire rated assembly standards and include scope items like hoist beams, elevator cabs, guide rails and pit construction.

The related solicitation seeks proposals for HVAC system repairs at the same PA 206 Horsham facility. The special notice was released by the U.S. Army Corps of Engineers Philadelphia District for an unrestricted procurement. No further information is provided on response dates, award timing, pricing structure or other procurement details. Architectural modernization drawings and a brief HVAC repair solicitation notice are the extent of the documentation included.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-811

A5 1/4" = 1’-0"

A1 1/2" = 1’-0"

ELEVATOR - FIRST FLOOR PLAN

B5 1/4" = 1’-0"

ELEVATOR - SECOND FLOOR PLAN

ELEVATOR - SECTION

A3

1/2" = 1’-0"

ELEVATOR - SECTION

T R

A

IN

IN

G C

E N

T E

R E

N L

A R

G E

D P

L A

N A

N D S

E C

T

IO

N E

L E

V A

T O

R

C5 1/4" = 1’-0"

ELEVATOR - PIT PLAN

2’ 4’0 1’

SCALE:1/2"=1’-0"

2’ 4’0 1’

SCALE:1/2"=1’-0"

4’ 8’0 2’

SCALE:1/4"=1’

PLAN

NORTH

4’ 8’0 2’

SCALE:1/4"=1’

PLAN

NORTH

4’ 8’0 2’

SCALE:1/4"=1’

PLAN

NORTH

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-811.dgn

9/11/2012

9:27:45 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -8

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

D

/8

A3

A1

8’-10 1/4 " CLEAR 2’-9 3/8 "

1’-11 1/4 " 7’-7 3/8 " 2’-7 5/8 "

D

210J

CLOSET

A

ELEVATOR

ELEVATOR RM.

A

ELEVATOR

4A

S

4A

S

4A

S

4A

S

4A

S

1A

S

1A

S

2A

T

2A

T

210J

D

2’-9 3/8 "8’-10 1/4 "

2E

S

2E

S

2E

S

1’-1 5/8 "

3’-6"4’-2 5/8 "

4’-2 5/8 " 3’-6" 1’-1 5/8 "

SW

SW

SW

SW

SW

SW

SW

ELEVATOR

GUIDE RAILS

ACCESS LADDER

ELEVATOR PIT

FOUNDATION

WALL

LINE OF

ELEVATOR PIT

FOUNDATION

SUMP PIT

2’-0" D.

SW

SW

SW

2’-0"

3.22.7

/8

C L E

A R

/2

/8

C L E

A R

/2

A3

A1

8’-10 1/4 " CLEAR 2’-9 3/8 "

/8

C L E

A R

/2

100’-0"

1ST FLOOR

114’-0"

2ND FLOOR

94’-8"

ELEVATOR PIT

2ND FLOOR

114’-0"

1ST FLOOR

100’-0"

ELEVATOR PIT

94’-8"

00-A-812

C4

A4

3 D

2’-10" 6 1/2 "

128’-0"

RATED SHAFT CEILING

128’-0"

RATED SHAFT CEILING

HOIST BEAM

HOIST BEAM

2HR RATED SHAFT WALL ASSEMBLY

2HR RATED SHAFT WALL

ASSEMBLY

ACCESS LADDER

LIGHT FIXTURE

LIGHT SWITCH AND

GFIC OUTLET

ELEVATOR CAB

WATERPROOFING MEMBRANE

SEE SPEC

TUBE STEEL STRUCTURAL BACKUP

BEYOND

A2

00-A-812

FIRE RATED CEILING ASSEMBLY

REFER TO NER 258

FIRE RATED CEILING ASSEMBLY

REFER TO NER 258

File details come from the government source that posted it. Updated .