AFA040-1.PDF
PDF 456 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document package includes architectural drawings and plans for an Army Reserve Training Center renovation project. The drawings show details for Stair A, including section views, first and second floor plans, and dimensions. The project is located at the Willow Grove Naval Air Station in Horsham, Pennsylvania. The related federal contract opportunity is a Special Notice from the U.S. Army Corps of Engineers Philadelphia District seeking proposals for HVAC system repairs at the PA 206 facility in Horsham. The solicitation number is W912BU24R0001 and responses are due based on the details in the Special Notice.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF | ||
| AF2040-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-801 A5
1/4" = 1’-0"
B5 1/4" = 1’-0"
A1 1/2" = 1’-0"
STAIR A - SECTION STAIR A- FIRST FLOOR PLAN
STAIR A - SECOND FLOOR PLAN
T R
A
IN
IN
G C
E N
T E
R E
N L
A R
G E
D P
L A
N A
N D S
E C
T
IO
N S
T A
IR
PLAN
NORTH
PLAN
NORTH
4’ 8’0 2’
SCALE:1/4"=1’
4’ 8’0 2’
SCALE:1/4"=1’
2’ 4’0 1’
SCALE:1/2"=1’-0"
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-801.dgn
9/11/2012
9:27:07 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -8
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
E
E
A1
A
A
2E
S
1A
S
2E
S
2E
S
2E
S
STAIR
STAIR
2E
S
2.7 3.2
2.7 3.2
4’-5 5/8 "
7" 11"
2’-3 3/4 " 11 TREADS @ 11" = 10’-1" 7’-5 7/8 "
10 5/8 "
11 1/4 " 1’-0"
1’-11"
/8
/8
/4
/4
/2
/2
/4
/4
1/4 " 1’-11"
1’-0"
6’-4 1/2 "
7 1/4 " E.O.D.
1’-8 1/2 " 11 TREADS @ 11" = 10’-1" 8’-4 7/8 " 10 5/8 "
5’-9 1/2 " 7" 11"
/8
/8
26’-9 1/4 "
25’-10 1/4 "
11 1/4 "
5’-0 5/8 " 2 1/4 "
1A
S
00-A-803
C4
00-A-803
SW
SW
SW
SW
SW
SW
RECESS 2ND FLOOR LANDING
CONC. POUR TO ACCEPT FLUSH
TILE FIT
114’-0"
2ND FLOOR
107’-0"
1ST FLOOR
100’-0"
INTERMEDIATE LANDING
R
IS
E R
S
E A
R
IS
E R
S
E A
00-A-803
OPP
A4
00-A-803
C1
122’-8"
RATED STAIRWELL CEILING
MTL. STUD AND GYP. ENCLOSURE
UNDER STAIR BEYOND
FIRE RATED CEILING ASSEMBLY
REFER TO NER-258
WALL MOUNTED HANDRAIL
A2
00-A-804
File details come from the government source that posted it. Updated .