This document contains architectural drawings and specifications for building renovations as well as details for a related federal contract opportunity. The architectural drawings depict exterior elevations and sections for renovations to an existing Army Reserve Training Center building located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The project involves repairs and upgrades to the building's HVAC systems. The related federal contract opportunity is solicitation number W912BU24R0001 issued by the U.S. Army Corps of Engineers Philadelphia District for HVAC system repairs at the PA 206 Horsham facility. The opportunity is designated as a special notice and responses are due based on the solicitation schedule.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-A-2011/8" = 1’ 0" A4

SOUTH ELEVATION

1/8" = 1’ 0" C4

WEST ELEVATION

8’0 4’ 16’

SCALE:1/8"=1’

8’0 4’ 16’

SCALE:1/8"=1’

AS-BUILT

O M

S A

M S

A E

X T

E R

IO

R E

L E

V A

T

IO

N S

S

O U

T H A

N D W

E S

T

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-201.dgn

9/11/2012

9:33:04 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -2

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

NOTE: EXTERIOR MATERIAL PALETTE TO MATCH

EXISTING BUILDING: SECURITY FORCES SQUADRON 111

EDC.5CB.5BA

NOTE: SEE SHEET 10-A-203 FOR MASONRY

CONTROL JOINT LOCATIONS

NOTE: SEE SHEET 10-A-203 FOR MASONRY

CONTROL JOINT LOCATIONS

1 2 3 4 5

FIRST FLOOR

100’-0"

T.O.S.

118’-1 1/2" T.O.S.

T.O.S. RIDGE

FIRST FLOOR

100’-0"

T.O.S.

118’-1 1/2" T.O.S.

T.O.S. RIDGE

/8

/8

/8

1.5

/8

/8

/8

10-A-303

A1 A1

10-A-302

A2

10-A-302

10-A-303

A2

62223432

10-A-301

B3

A5

B3

14’-8"

1’-0"

8’-0" 1’-4"10’-10"

2’-0" 4’-8"

131’-2 1/8"

113’-10 7/8"

131’-2 1/8"

113’-10 7/8"

SHEET NOTES

61CLOSURE

SHINGLE ROOFING

RIGID ROOF INSULATION (R-30)

METAL ROOF DECK

MEMBRANE ROOFING

WOOD BLOCKING

AIR SPACE

RIGID INSULATION (R-12.5)

6" METAL STUDS AT 16" O.C.

BATT INSULATION (R-19)

METAL SOFFIT PANEL

BRICK VENEER

CONCRETE SLAB ON GRADE

AIR BARRIER

8" CMU

STEEL LINTEL

SCHEDULED CEILING

METAL FURRING CHANNEL

5/8" GYPSUM BOARD

PERIMETER INSULATION (R-10)

SECTIONAL OVERHEAD DOOR

METAL COPING

H.M. DOOR AND FRAME

MASONRY TIES AT 16" O.C.

METAL ROOF PANELS

METAL ROOF PURLIN

METAL WALL PANELS

EAVE STRUT

STEEL BASE ANGLE

BASE CLOSURE

STEEL FRAME BEYOND

ENDWALL POST BEYOND

CONTOUR GABLE TRIM

CAP FLASHING

HALF HEIGHT MASONRY

STARTER COURSE

STEEL GRATE PLATFORM -

SEE STRUCTURAL

FIRE TREATED OSB EXTERIOR

SHEATHING

CONCRETE SLAB W/ METAL DECK -

SEE STRUCTURAL DRAWINGS

CONCRETE FOUNDATION -

SEE STRUCTURAL DRAWINGS

ALUMINUM STORE FRONT

W/ LAMINATED INSULATING GLASS

STEEL BEAM -

SEE STRUCTURAL DRAWINGS

STEEL JOIST -

SEE STRUCTURAL DRAWINGS

METAL SIDEWALL GIRT VAPOR BARRIER

PRE-FINISHED SHEET MTL. FASCIA

PANEL WITH STIFFENING RIBS

LIGHT GA. CLIP

STL. ANGLE CLIP: SEE STRUCT.

PRE-FINISHED SHEET MTL. WALL

PANEL

ALUMINUM SUPPORT ANGLE - SEE

STRUCTURAL

PRE-ENGINEERED CANOPY WITH

METAL DOWN SPOUT

SEE DETAILS A4 AND C4 ON SHEET

00-A-533

6"X6" METAL GUTTER WITH 4"X5"

DOWN SPOUT

METAL OVERFLOW SCUPPER WITH

6"X6" DOWNSPOUT:

SEE C5 / D5 ON SHEET 00-A-531

STL. FRAME MAIN ENTRY CANOPY

EXTERIOR GYPSUM SHEATHING

ROOF INSULATION (R-20)

WALL INSULATION (R-15)

METAL LINER PANEL

LOUVER - SEE MECHANICAL

OPENING FOR MECHANICAL

EQUIPMENT - SEE MECHANICAL

SPLIT FACED CMU VENEER - USE

SMOOTH FACE AT CANOPIES

62 FIXED ALUMINUM WINDOW

PRECAST CONCRETE SILL

File details come from the government source that posted it. Updated .