AFC2EA-1.PDF

PDF 2 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This reflected ceiling plan and federal contract opportunity document provides details for HVAC system repairs at the PA 206 Horsham facility. The reflected ceiling plan outlines the layout of the second floor ceiling for the Army Reserve Training Center in Horsham, PA, including ceiling heights, light fixtures, sprinkler heads, and other reflected ceiling details. The related federal contract opportunity is solicitation number W912BU24R0001 from the U.S. Army Corps of Engineers Philadelphia District for HVAC system repairs at the PA 206 Horsham facility. The opportunity type is listed as a special notice. No other salient details are provided regarding response dates, award dates, set-asides, pricing terms, incumbents or required products/services.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
AF2040-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-112

1/16" = 1’ 0" A4

OVERALL SECOND FLOOR REFLECTED CEILING PLAN

T R

A

IN

IN

G C

E N

T E

R O

V E

R A

L L S

E C

O N

D F

L O

O R

R E

F L E

C T

E D C

E

IL

IN

G P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-112.dgn

5/30/2013

4:20:52 PM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/3

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

223A

TM1 153 UE OFFICE

223B

223C

224A

HQ 223 UE OFFICE

224B

HQ 223 F/T OFFICE

224C

224D

224E

220V

338 PS OFFICE

220W

222A

TM8 153 OFFICE

221A

TM8 153 PS OFC

223D

TM8

153 PS OFC

220N

F/T OFFICE

220M

F/T OFFICE

220U

338 PS OFC

220T

220S

220R

338 PS OFFICE220Q

220J

338 F/T OFFICE

220K

220L

220E

220F

220G

220O

220P

338 PS OFC

220H

220I

338 F/T OFC

220A

338 UE OFFICE 220B

338 UE OFFICE

220C

220D

B

STAIR

202A

ELEC

210A

UNIT COMMON

213I

157 F/T OFFICE

216A

TM26 150 PS OFC

226A

427 F/T OFC

226B

427 PS OFC

226C

427 F/T OFC

MECH

218A

TM32 154 PS OFC

217A

TM32 154 PS OFC

213P

157 PS OFFICE

213H

213G

213O

213N

213F

213E

213M

230B

UC AREA

213L

213K

210G

STORAGE

213J

213D

225B

369 F/T OFFICE

225C

369 F/T OFFICE

215E

367 F/T OFFICE

215D

215C

214A

DRT 733 F/T OFC

213C

157 UE OFFICE

213B

213A

225A

369 UE OFFICE

215A

215B

367 UE OFFICE

211B

DET 317 UE OFC

211A

DET 317 UE OFC

A

STAIR

227B

RSC 99 F/T OFC

227C

LOBBY

A

ELEVATOR

210H

210J

CLOSET

211C

DET 317 PS OFC

211D

DET 317 PS OFC

212A

DET 430 PS OFC

219A

109 PS OFC

210F

BREAK / VENDING

WOMEN

JANITOR

MEN

202B

ELEC

227A

210B

ADMIN COMMON

B

C

D

D.1

E

PLAN

NORTH

2 3 4 5 6 6.4 7 7.8 8 9 10

D.6

2.7 3.2

210C

GENERAL SUPPORT

210D

FACILITY STORAGE

TER.

210I

201C

CORR

201D

201A

201B

201G

201F

201H

M A

T C

H L

IN

E

A

-A -1

M A

T C

H L

IN

E

A

-A -1

S

S

S

S

S

S

S

S

S

S

S

S S S

S

S

S

P

P P P P

P

P

P

TNAC

H

F

F

C A

CA

C A CA

C

A

C

A

C A

C

A

C

A

C

A

C A

C A

C

A

C

A

C

A

C

A

C

A

C

A

C

A

CA

C

A

C

A

C A

C

A

C

A

C A

C A

C

A

C

A

C

A

C

A

S S

L O

C

L O

C

S

S S SS

S

S

S

S S

SS

S S S S S

S

S S S

S S

S S S S S S S S S

S

SSSSSSSS

S

S S

S

S

S

S S

S

S

S

S

S S S S S S S S

S S S

S S

S S S S S S

S

S S S

S S

S S S S S

SS

S

S

REFLECTED CEILING LEGEND

8’-8"

R

CEILING TAG

PROJECTION SCREEN

CAN LIGHT

SUSPENDED LIGHT

FIXTURE

SURFACE MOUNTED

LIGHT FIXTURE

UPRIGHT

SPRINKLER

HEAD

SPRINKLER

HEAD

LAY IN

LIGHT

FIXTURE

RETURN/

EXHAUST

SUPPLY

PROJECTOR

ACOUSTICAL

CEILING TILE

GYP. BOARD

CEILING

SEE FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR FURTHER INFORMATION

1. ALL CEILINGS ON THE FIRST FLOOR OF THE TRAINING BUILDING TO

BE 8’-8" A.F.F., U.N.O.

2. ALL CEILINGS ON THE SECOND FLOOR OF THE TRAINING BUILDING

TO BE 8’-8" A.F.F., U.N.O.

3. ALL CEILINGS IN THE OMS / AMSA BUILDING TO BE 8’-8" A.F.F.,

U.N.O.

4. REFER TO THE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE

LIGHTING AND DIFFUSER LAYOUT.

5. ALL BULKHEADS ARE TO BE TYPE 2A / T, SEE REFLECTED CEILING

PLANS FOR HEIGHTS.

6. PROJECTION SCREENS AND PROJECTORS ARE SHOWN FOR

LOCATION SUGGESTION ONLY, SEE ELECTRICAL DRAWINGS FOR

FINAL LOCATIONS.

7. ALL CEILINGS NOTED AS O.T.S. (OPEN TO STRUCTURE) SHALL BE PAINTED

File details come from the government source that posted it. Updated .