This document contains architectural drawings and specifications for repairs to HVAC systems at the PA 206 Horsham facility. The solicitation is being conducted by the Department of the Army Corps of Engineers Engineering District Philadelphia under number W912BU24R0001. The drawings depict existing wall sections, floor plans, and details for the facility and specify repairs to the HVAC systems, including replacement of air handling units, fans, ductwork, controls and other components. Proposed repairs are intended to improve energy efficiency and indoor air quality at the facility. The response deadline is not stated in the document.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-303 1/2" = 1’-0"

A3

WALL SECTION

1/2" = 1’-0" A1

WALL SECTION

T R

A

IN

IN

G C

E N

T E

R W

A L L S

E C

T

IO

N S

2’ 4’0 1’

SCALE:1/2"=1’-0"

2’ 4’0 1’

SCALE:1/2"=1’-0"

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-303.dgn

9/11/2012

9:23:01 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -3

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

100’-0"

1ST FLOOR

T.O. STEEL

126’-2"

114’-0"

2ND FLOOR

1’-8" 5’-0"

1’-8"

T.O. WALL

115’-4"

115’-4"

T.O. WALL

2ND FLOOR

114’-0"

126’-2"

T.O. STEEL

100’-0"

1ST FLOOR

41’-4"

1’-8"

1’-8" 5’-0"

B A 2 1

2 2

13 13

15 15

14’-8"

00-A-521

00-A-531

00-A-701

A4

A5

C4

B3

OPP

A5

TYP.

TYP.

54 54

112’-0"

T.O. STEEL

111’-6 7/8"

T.O. STEEL

A2

00-A-533

SIM.

CLOSURE

SHINGLE ROOFING

RIGID ROOF INSULATION (R-30)

METAL ROOF DECK

WOOD BLOCKING

RIGID INSULATION (R-12.5)

6" METAL STUDS AT 16" O.C.

BATT INSULATION (R-19)

EXTERIOR GYPSUM SHEATHING

BRICK VENEER

CONCRETE SLAB ON GRADE

8" CMU

STEEL LINTEL

SCHEDULED CEILING

METAL FURRING CHANNEL

5/8" GYPSUM BOARD

PERIMETER INSULATION (R-10)

SECTIONAL OVERHEAD DOOR

METAL COPING

H.M. DOOR AND FRAME

MASONRY TIES AT 16" O.C.

METAL ROOF PANELS

METAL ROOF PURLIN

ROOF INSULATION

METAL WALL PANELS

EAVE STRUT

WALL INSULATION

STEEL BASE ANGLE

BASE CLOSURE

STEEL FRAME BEYOND

ENDWALL POST BEYOND

CONTOUR GABLE TRIM

CAP FLASHING

SHEET NOTES

HALF HEIGHT MASONRY

STARTER COURSE

STEEL GRATE PLATFORM -

SEE STRUCTURAL

FIRE TREATED OSB EXTERIOR

SHEATHING

CONCRETE SLAB W/ METAL DECK -

SEE STRUCTURAL DRAWINGS

CONCRETE FOUNDATION -

SEE STRUCTURAL DRAWINGS

ALUMINUM STORE FRONT

W/ LAMINATED INSULATING GLASS

STEEL BEAM -

SEE STRUCTURAL DRAWINGS

STEEL JOIST -

SEE STRUCTURAL DRAWINGS

METAL SIDEWALL GIRT

VAPOR BARRIER

PRE-FINISHED SHEET MTL. FASCIA

PANEL WITH STIFFENING RIBS

STL. ANGLE CLIP: SEE STRUCT.

PRE-FINISHED SHEET MTL. WALL

PANEL

ALUMINUM SUPPORT ANGLE - SEE

STRUCTURAL

PRE-ENGINEERED CANOPY WITH

METAL DOWN SPOUT

SEE DETAILS A4 AND C4 ON SHEET

00-A-533

6"X6" METAL GUTTER WITH 4"X5"

DOWN SPOUT

METAL OVERFLOW SCUPPER WITH

6"X6" DOWNSPOUT:

SEE C5 / D5 ON SHEET 00-A-531

STL. FRAME MAIN ENTRY CANOPY

METAL LINER PANEL

LOUVER - SEE MECHANICAL

OPENING FOR MECHANICAL

EQUIPMENT - SEE MECHANICAL

SPLIT FACED CMU VENEER - USE

SMOOTH FACE AT CANOPIES

EPDM MEMBRANE ROOFING

EPDM MEMBRANE ROOFING ON

TAPERED INSULATION

COLUMN BEYOND

LIGHT GA. CLIP WITH SLIP

CONNECTION

BOND BEAM

AIR SPACE - 1 1/2" MIN.

VENTED METAL SOFFIT PANEL

CONTINUOUS AIR AND MOISTURE

BARRIER SYSTEM (A.M.B.S.)

PRE-FINISHED ALUMINUM LOUVER

REFER TO LOUVER SCHEDULE

ON SHEET 00-A-602

PRECAST CONCRETE SILL

66 FIXED ALUMINUM WINDOW

PARTIAL HEIGHT WALL PER

FLOOR PLAN. RETURN TOP

OF WALL TO EXTERIOR WALL