AFD0DC-1.PDF
PDF 791 KB Posted
- Attached to
- PA 206 HORSHAM HVAC SYSTEMS REPAIRS
- Solicitation number
- W912BU24R0001
About this file
This document contains architectural drawings and specifications for repairs to HVAC systems at the PA 206 Horsham facility. The solicitation is being conducted by the Department of the Army Corps of Engineers Engineering District Philadelphia under number W912BU24R0001. The drawings depict existing wall sections, floor plans, and details for the facility and specify repairs to the HVAC systems, including replacement of air handling units, fans, ductwork, controls and other components. Proposed repairs are intended to improve energy efficiency and indoor air quality at the facility. The response deadline is not stated in the document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-303 1/2" = 1’-0"
A3
WALL SECTION
1/2" = 1’-0" A1
WALL SECTION
T R
A
IN
IN
G C
E N
T E
R W
A L L S
E C
T
IO
N S
2’ 4’0 1’
SCALE:1/2"=1’-0"
2’ 4’0 1’
SCALE:1/2"=1’-0"
AS-BUILT
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-303.dgn
9/11/2012
9:23:01 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -3
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
100’-0"
1ST FLOOR
T.O. STEEL
126’-2"
114’-0"
2ND FLOOR
1’-8" 5’-0"
1’-8"
T.O. WALL
115’-4"
115’-4"
T.O. WALL
2ND FLOOR
114’-0"
126’-2"
T.O. STEEL
100’-0"
1ST FLOOR
41’-4"
1’-8"
1’-8" 5’-0"
B A 2 1
2 2
13 13
15 15
14’-8"
00-A-521
00-A-531
00-A-701
A4
A5
C4
B3
OPP
A5
TYP.
TYP.
54 54
112’-0"
T.O. STEEL
111’-6 7/8"
T.O. STEEL
A2
00-A-533
SIM.
CLOSURE
SHINGLE ROOFING
RIGID ROOF INSULATION (R-30)
METAL ROOF DECK
WOOD BLOCKING
RIGID INSULATION (R-12.5)
6" METAL STUDS AT 16" O.C.
BATT INSULATION (R-19)
EXTERIOR GYPSUM SHEATHING
BRICK VENEER
CONCRETE SLAB ON GRADE
8" CMU
STEEL LINTEL
SCHEDULED CEILING
METAL FURRING CHANNEL
5/8" GYPSUM BOARD
PERIMETER INSULATION (R-10)
SECTIONAL OVERHEAD DOOR
METAL COPING
H.M. DOOR AND FRAME
MASONRY TIES AT 16" O.C.
METAL ROOF PANELS
METAL ROOF PURLIN
ROOF INSULATION
METAL WALL PANELS
EAVE STRUT
WALL INSULATION
STEEL BASE ANGLE
BASE CLOSURE
STEEL FRAME BEYOND
ENDWALL POST BEYOND
CONTOUR GABLE TRIM
CAP FLASHING
SHEET NOTES
HALF HEIGHT MASONRY
STARTER COURSE
STEEL GRATE PLATFORM -
SEE STRUCTURAL
FIRE TREATED OSB EXTERIOR
SHEATHING
CONCRETE SLAB W/ METAL DECK -
SEE STRUCTURAL DRAWINGS
CONCRETE FOUNDATION -
SEE STRUCTURAL DRAWINGS
ALUMINUM STORE FRONT
W/ LAMINATED INSULATING GLASS
STEEL BEAM -
SEE STRUCTURAL DRAWINGS
STEEL JOIST -
SEE STRUCTURAL DRAWINGS
METAL SIDEWALL GIRT
VAPOR BARRIER
PRE-FINISHED SHEET MTL. FASCIA
PANEL WITH STIFFENING RIBS
STL. ANGLE CLIP: SEE STRUCT.
PRE-FINISHED SHEET MTL. WALL
PANEL
ALUMINUM SUPPORT ANGLE - SEE
STRUCTURAL
PRE-ENGINEERED CANOPY WITH
METAL DOWN SPOUT
SEE DETAILS A4 AND C4 ON SHEET
00-A-533
6"X6" METAL GUTTER WITH 4"X5"
DOWN SPOUT
METAL OVERFLOW SCUPPER WITH
6"X6" DOWNSPOUT:
SEE C5 / D5 ON SHEET 00-A-531
STL. FRAME MAIN ENTRY CANOPY
METAL LINER PANEL
LOUVER - SEE MECHANICAL
OPENING FOR MECHANICAL
EQUIPMENT - SEE MECHANICAL
SPLIT FACED CMU VENEER - USE
SMOOTH FACE AT CANOPIES
EPDM MEMBRANE ROOFING
EPDM MEMBRANE ROOFING ON
TAPERED INSULATION
COLUMN BEYOND
LIGHT GA. CLIP WITH SLIP
CONNECTION
BOND BEAM
AIR SPACE - 1 1/2" MIN.
VENTED METAL SOFFIT PANEL
CONTINUOUS AIR AND MOISTURE
BARRIER SYSTEM (A.M.B.S.)
PRE-FINISHED ALUMINUM LOUVER
REFER TO LOUVER SCHEDULE
ON SHEET 00-A-602
PRECAST CONCRETE SILL
66 FIXED ALUMINUM WINDOW
PARTIAL HEIGHT WALL PER
FLOOR PLAN. RETURN TOP
OF WALL TO EXTERIOR WALL
File details come from the government source that posted it. Updated .