AF97A7-1.PDF

PDF 794 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains architectural plans and drawings for renovations to the HVAC systems at the Army Reserve Training Center in Horsham, Pennsylvania. The plans show layouts and details for mechanical, electrical, and plumbing systems in various buildings on site. Renovations include installation of new air handling units, ductwork, controls, and other HVAC components. The solicitation number for related repair work is W912BU24R0001, issued by the U.S. Army Corps of Engineers Philadelphia District. The drawings provide specifications and notes regarding materials, dimensions, partitions, finishes, and other requirements applicable to the HVAC systems repair project at this facility.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-403 1/4" = 1’-0"

A4

ENLARGED PLAN

D3 1/4" = 1’-0"1/4" = 1’-0"

D1

C1 1/4" = 1’-0"

SECTION AT VAULT

SECTION AT VAULT

SECTION AT VAULT

AS-BUILT

T R

A

IN

IN

G C

E N

T E

R E

N L

A R

G E

D P

L A

N S

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-403.dgn

9/11/2012

9:24:02 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

4’ 8’0 2’

SCALE:1/4"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -4

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

6.4 7

B

116B

VAULT

10’-5"12’-11" 8’-7" 2’-6"

12’-11"

/8

/8

116A

ARMORY

116A.2

5’-8"5’-8" 4"

/2

/2

5’-8"5’-8"4"

5’-8" 5’-8" 4"

/2

/2

10 1/8 "

PLAN

NORTH

TYP.

TYP.

DEHUMIDIFIER, PLUMBER TO PROVIDE FLOOR DRAIN

CAST-IN-PLACE FLOOR ANCHORS - NEENAH MOORING EYE R-3490 OR EQUAL

RIFLE RACKS: GFGI

SHOWN FOR LOCATION PURPOSES

WIRE MESH CAGE WALLS AND DOORS INSTALLED FLOOR TO CEILING

FIRE EXTINGUISHER (BRACKET MOUNTED)

CONCRETE CAST IN PLACE WALLS, SEE STRUCTURAL FOR DIMENSIONS

INTRUSION DETECTION SYSTEM PANEL

A .1

/2

/2

/2

/2

/2

/2

/2

/2

C L

C L

C L

C L

C L

C L

C L

3’-11"3’-0"3’-0"3’-0"

C L

C L

C L

C L

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

SLIDE

DIRECTION

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

100’-0"

FIRST FLOOR

110’-0"

T.O. VAULT

00-A-402

A2A2

00-A-402

00-A-402

A2

PADLOCK LUG WELDED TO

SLIDING DOOR FRAME

PROVIDE CORRESPONDING

LUG WELDED TO CAGE POST

(TYP)

STEEL U BRACKET

SIM.

SIM. SIM.

D3

D1

C1

COLUMN BEYOND

00-A-402

D2

D4

D1

COLUMN BEYOND

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND

00-A-500.

8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.

4’ 8’0 2’

SCALE:1/4"=1’

GENERAL NOTES

GRAPHIC SCALE

KEY NOTES

File details come from the government source that posted it. Updated .