This document contains architectural plans and drawings for renovations to the HVAC systems at the Army Reserve Training Center in Horsham, Pennsylvania. The plans show layouts and details for mechanical, electrical, and plumbing systems in various buildings on site. Renovations include installation of new air handling units, ductwork, controls, and other HVAC components. The solicitation number for related repair work is W912BU24R0001, issued by the U.S. Army Corps of Engineers Philadelphia District. The drawings provide specifications and notes regarding materials, dimensions, partitions, finishes, and other requirements applicable to the HVAC systems repair project at this facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912BU24R0001 Amendment 0009_Cancellation.pdf | ||
| W912BU24R0001 Amendment 0005.pdf | ||
| 10-M-800.pdf | ||
| AF85D7-1.PDF | ||
| AFA040-1.PDF | ||
| 00-M-806.pdf | ||
| AF0F76-1.PDF | ||
| 00-MP-4.PDF | ||
| AF6B67-1.PDF | ||
| 10-M-803.pdf | ||
| AFDA0C-1.PDF | ||
| 00-M-201.pdf | ||
| AF7DA6-1.PDF | ||
| AF5B0D-1.PDF | ||
| AF4200-1.PDF | ||
| 10-MH-1.PDF | ||
| AF2EB8-1.PDF | ||
| AF7BD0-1.PDF | ||
| AF4273-1.PDF | ||
| 00-M-803.pdf | ||
| 10-M-801.pdf | ||
| 00-MP-2.PDF | ||
| AF1533-1.PDF | ||
| AF9D68-1.PDF | ||
| AFC2EA-1.PDF | ||
| AF2AEE-1.PDF | ||
| AFD99B-1.PDF | ||
| AF26AC-1.PDF | ||
| W912BU24R0001 Amendment 0004.pdf | ||
| AFFB36-1.PDF | ||
| 00-M-807.pdf | ||
| 00-M-808.pdf | ||
| AF9FDC-1.PDF | ||
| AF47CB-1.PDF | ||
| AFRC55-2.PDF | ||
| 00-M-802.pdf | ||
| AFFC3F-1.PDF | ||
| AFC8A7-1.PDF | ||
| AF8E75-1.PDF | ||
| AFD903-1.PDF | ||
| AF54B2-1.PDF | ||
| AFD078-1.PDF | ||
| 00-MH-1.PDF | ||
| AF0EF7-1.PDF | ||
| 00-MP-1.PDF | ||
| 00-M-805.pdf | ||
| 00-MH-4.PDF | ||
| AF377B-1.PDF | ||
| AF9D55-1.PDF | ||
| AFE9FE-1.PDF |
Show 40 more
Latest 50 of 102 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
00-A-403 1/4" = 1’-0"
A4
ENLARGED PLAN
D3 1/4" = 1’-0"1/4" = 1’-0"
D1
C1 1/4" = 1’-0"
SECTION AT VAULT
SECTION AT VAULT
SECTION AT VAULT
AS-BUILT
T R
A
IN
IN
G C
E N
T E
R E
N L
A R
G E
D P
L A
N S
S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-403.dgn
9/11/2012
9:24:02 AM
rifem
F O
R U
M S
T U
D
IO
I
N N
E R
B E
L T B
U S
IN
E S
S C
E N
T E
R D
R
S T L
O U
IS
M O
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
fi
US Army Corps of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
A N
S I
D
L O
U
IS
V
IL
L E D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K Y
4’ 8’0 2’
SCALE:1/4"=1’
F S
B A
Z
C L
A Y
C O C
O N
S T
R U
C T
IO
N
.1
.1
-W
Q R -0
-R -0
P -1
1 3
C O
N C
E P
T D
E S
IG
N S
U B
M
IT
T A
L .1
.0
.1
.0
R
E V
IS
E D C
H A
R R
E T
T E C
O N
C E
P T S
U B
M
IT
T A
L
IN
T
E R
IM
S
U B
M
IT
T A
L .1
.1
.2
.1
A F
R C
-A -4
.d g n
/1
/2
F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L
A R
M Y R
E S
E R
V E T
R A
IN
IN
G C
E N
T E
R W
IL
L O
W G
R O
V E N
A V
A L A
IR
S
T A
T
IO
N W
Q R -0
-C -0
H O
R S
H A
M P
A
C
O R
R E
C T
E D F
IN
A L D
E S
IG
N S
U B
M
IT
T A
L .0
.1
.1
.1
C
E R
T
IF
IE
D F
IN
A L S
U B
M
IT
T A
L
B R
IC
E Z
IC
K U
H R
6.4 7
B
116B
VAULT
10’-5"12’-11" 8’-7" 2’-6"
12’-11"
/8
/8
116A
ARMORY
116A.2
5’-8"5’-8" 4"
/2
/2
5’-8"5’-8"4"
5’-8" 5’-8" 4"
/2
/2
10 1/8 "
PLAN
NORTH
TYP.
TYP.
DEHUMIDIFIER, PLUMBER TO PROVIDE FLOOR DRAIN
CAST-IN-PLACE FLOOR ANCHORS - NEENAH MOORING EYE R-3490 OR EQUAL
RIFLE RACKS: GFGI
SHOWN FOR LOCATION PURPOSES
WIRE MESH CAGE WALLS AND DOORS INSTALLED FLOOR TO CEILING
FIRE EXTINGUISHER (BRACKET MOUNTED)
CONCRETE CAST IN PLACE WALLS, SEE STRUCTURAL FOR DIMENSIONS
INTRUSION DETECTION SYSTEM PANEL
A .1
/2
/2
/2
/2
/2
/2
/2
/2
C L
C L
C L
C L
C L
C L
C L
3’-11"3’-0"3’-0"3’-0"
C L
C L
C L
C L
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
SLIDE
DIRECTION
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
100’-0"
FIRST FLOOR
110’-0"
T.O. VAULT
00-A-402
A2A2
00-A-402
00-A-402
A2
PADLOCK LUG WELDED TO
SLIDING DOOR FRAME
PROVIDE CORRESPONDING
LUG WELDED TO CAGE POST
(TYP)
STEEL U BRACKET
SIM.
SIM. SIM.
D3
D1
C1
COLUMN BEYOND
00-A-402
D2
D4
D1
COLUMN BEYOND
1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING
TO BE TYPE 2A / S, SW. U.N.O.
2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING
BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.
3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,
SW. U.N.O.
4. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE
CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC
SPACES.
5. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND
EQUIPMENT LAYOUTS.
6. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE
OF GYP.
7. SEE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003 AND
00-A-500.
8. SEE FINISH SCHEDULE AND FINISH PLANS FOR ALL FINISH INFO.
4’ 8’0 2’
SCALE:1/4"=1’
GENERAL NOTES
GRAPHIC SCALE
KEY NOTES
File details come from the government source that posted it. Updated .