AF970C-1.PDF

PDF 841 KB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains architectural plans and specifications for renovations to an Army Reserve Training Center located at Naval Air Station Willow Grove in Horsham, Pennsylvania. The plans detail layouts for classrooms, offices, mechanical and electrical rooms, restrooms, and storage areas for the one-story OMS/AMSA building and two-story training building. Renovations include installation of partition walls, doors, coat hooks, corner guards, blinds, and furniture and equipment as specified. Mechanical, electrical, and civil drawings are also referenced. The related federal contract opportunity is a special notice from the U.S. Army Corps of Engineers Engineering District Philadelphia seeking bids for HVAC system repairs at the same PA 206 Horsham facility.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-A-101

1/16" = 1’ 0" A4

OVERALL FLOOR PLAN

O M

S A

M S

A O

V E

R A

L L F

L O

O R P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5510-A-101.dgn

9/11/2012

9:32:00 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

10-A-301

A5

A5

10-A-201

A4

10-A-201

C4

10-A-202

A4

10-A-202

C4

B3

B3

B5

B5 149

AMSA BATTERY ROOM

OMS FLAM STOR

AMSA SHOP OFFICE

150C

ALCOVE

150B

EQUIP ALCOVE

150A

WORK BAYS

143A

OMS SHOP OFFICE

143C

F/T OFFICE

143B

F/T OFFICE

AMSA CLASS

BREAK ROOM

ARNET/IT CLOSET

ELEC COMMO

145A

OMS STORAGE

153B

MENS LOCKERS

140C

VESTIBULE

153A

MENS

TLT / SHOWER

154A

WOMENS

TLT / SHOWER

154B

WOMENS LOCKERS

155A

AMS PARTS ROOM

155B

AMS TOOL ROOM

145B

OMS TOOL & PARTS

AMSA

CNTL WASTE STOR

AMSA FLAM STOR

LIBRARY

MECHANICAL

ELECTRICAL

OMS

CNTL WASTE STOR

140D

VESTIBULE

169’-4"

22’-4" 20’-4" 45’-8" 35’-10" 45’-2"

M A

T C

H L

IN

E

A

-A -1

M A

T C

H L

IN

E

A

-A -1

PLAN

NORTH

1 FROST SLAB W/ LEAN CONCRETE FILL

2 CONC. APRON RE: CIVIL

3 ROCK MULCH RE: CIVIL

1 11

11 3

5’-0"

1 1.5 2 3 4 5

E

D

C.5

C

B

A

B.5

1. ALL PARTITIONS ON THE FIRST FLOOR OF THE TRAINING BUILDING

TO BE TYPE 2A / S, SW. U.N.O.

2. ALL PARTITIONS ON THE SECOND FLOOR OF THE TRAINING

BUILDING TO BE TYPE 2A / T @ 10’-0", SW. U.N.O.

3. ALL PARTITIONS IN THE OMS / AMSA BUILDING TO BE TYPE 2A / S,

SW. U.N.O.

4. INSTALL A COAT HOOK ON THE WALL BEHIND THE DOOR IN ITS

OPENED POSITION IN THE SUPPLY OFFICE, FACILITY MANAGER,

FAMILY SUPPORT, REC / RET OFFICE, AND ALL PRIVATE OFFICES,

SEE THE TYPICAL MOUNTING HEIGHTS ELEVATION ON 00-G-003.

5. INSTALL POLYVINYL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN FOR ALL PUBLIC

SPACES.

6. INSTALL STEEL CORNER GUARDS 6" A.F.F. TO 6" BELOW THE

CEILING WHERE INDICATED ON THE PLAN IN THE UNIT STORAGE

SPACE ONLY.

7. PROVIDE BLINDS AT ALL EXTERIOR WINDOWS.

8. SEE THE INTERIOR DRAWINGS FOR ALL FURNITURE AND

EQUIPMENT LAYOUTS.

9. DIMENSIONS ARE TO COLUMN LINES, FACE OF MASONRY, OR FACE

OF GYP.

10. REFER TO 00-G-003 FOR MATERIAL LEGEND OF HATCHED WALL TYPES.