AF8D0A-1.PDF

PDF 1 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains reflected ceiling plans and details for the second floor of an Army Reserve Training Center located at Willow Grove Naval Air Station in Horsham, Pennsylvania. The plans show the layout of ceilings, lighting fixtures, sprinkler heads, air diffusers, and other mechanical equipment. Dimensions and notes provide specifications for ceiling heights and materials. Related to this is a federal contract opportunity for HVAC system repairs at the PA 206 facility in Horsham. The solicitation is a Special Notice issued by the Department of the Army Corps of Engineers Philadelphia District. Services required include repairs to existing HVAC systems. No further details are provided on response date, award date, pricing or terms, set asides, or incumbent contractors.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-1161/8" = 1’ 0" A4

SECOND FLOOR RELFECTED CEILING PLAN - EAST

T R

A

IN

IN

G C

E N

T E

R S

E C

O N

D F

L O

O R

R E

F L E

C T

E D C

E

IL

IN

G P

L A

N E

A S

T

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-116.dgn

5/30/2013

4:21:46 PM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

8’0 4’ 16’

SCALE:1/8"=1’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/3

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

00-A-515

A5

226B

427 PS OFC

226C

427 F/T OFC

226A

427 F/T OFC

218A

TM32 154 PS OFC

217A

TM32 154 PS OFC210C

GENERAL SUPPORT

216A

TM26 150 PS OFC

213P

157 PS OFFICE

213O

157 PS OFFICE

213G

157 F/T OFFICE

213H

213I

210A

UNIT COMMON

220A

338 UE OFFICE

220B

201A

CORR

220C

220D

B

STAIR

220I

338 F/T OFC

220H

338 F/T OFFICE

220O

338 PS OFFICE

220P

338 PS OFC

201H

220M

F/T OFFICE

220N

F/T OFFICE

202A

ELEC

223A

TM1 153 UE OFFICE

223B

223C

224A

HQ 223 UE OFFICE

224B

HQ 223 F/T OFFICE

224C

224D

224E

220G

220F

220E

220J

220K

220L

201F

220Q

220R

220S

220T

220U

338 PS OFC

223D

TM8

153 PS OFC

221A

TM8 153 PS OFC

222A

TM8 153 OFFICE

220W

220V

201G

8’-0"

8’-0"

8’-0"

8’-0"

8’-0"8’-0"

8’-0"

8’-0"

8’-0"8’-0"

M A

T C

H L

IN

E

A

-A -1

PLAN

NORTH

10’-0"

6 6.4 7 7.8 8 9 10

A

B

C

D

E

S

S

S

S

P

P

F

C

A C

A

CA

C

A

C

A

C A

C

A

C

A

C A

C A

C

A

C

A

C

A

L O

C

S S S

S S S

S

SS

S S

S

S

S

S S

S

S

S

S

S S S S S S S S

S S S

S S

S S S S S S

S

S S S

S S

S S S S S

SS

S

S

TC

REFLECTED CEILING LEGEND

8’-8"

R

CEILING TAG

PROJECTION SCREEN

CAN LIGHT

SUSPENDED LIGHT

FIXTURE

SURFACE MOUNTED

LIGHT FIXTURE

UPRIGHT

SPRINKLER

HEAD

SPRINKLER

HEAD

LAY IN

LIGHT

FIXTURE

RETURN/

EXHAUST

SUPPLY

PROJECTOR

ACOUSTICAL

CEILING TILE

GYP. BOARD

CEILING

SEE FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR FURTHER INFORMATION

1. ALL CEILINGS ON THE FIRST FLOOR OF THE TRAINING BUILDING TO

BE 8’-8" A.F.F., U.N.O.

2. ALL CEILINGS ON THE SECOND FLOOR OF THE TRAINING BUILDING

TO BE 8’-8" A.F.F., U.N.O.

3. ALL CEILINGS IN THE OMS / AMSA BUILDING TO BE 8’-8" A.F.F.,

U.N.O.

4. REFER TO THE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE

LIGHTING AND DIFFUSER LAYOUT.

5. ALL BULKHEADS ARE TO BE TYPE 2A / T, SEE REFLECTED CEILING

PLANS FOR HEIGHTS.

6. PROJECTION SCREENS AND PROJECTORS ARE SHOWN FOR

LOCATION SUGGESTION ONLY, SEE ELECTRICAL DRAWINGS FOR

FINAL LOCATIONS.

7. ALL CEILINGS NOTED AS O.T.S. (OPEN TO STRUCTURE) SHALL BE PAINTED