AF641E-1.PDF

PDF 2 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document is a life safety plan for a training building at the Army Reserve Training Center in Horsham, Pennsylvania. It provides details on the building construction type, allowable heights and areas, fire resistance ratings for building elements, occupancy classifications, travel distances, and means of egress requirements. The related federal contract opportunity is a special notice from the U.S. Army Corps of Engineers Philadelphia District seeking repairs to HVAC systems at the PA 206 Horsham facility. No response date, award date, or pricing information is included.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-G-101

A2

FIRST FLOOR LIFE SAFETY PLAN - TRAINING BLDG

1/16" = 1’-0"

T R

A

IN

IN

G C

E N

T E

R F

IR

S T F

L O

O R L

IF

E S

A F

E T

Y P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\General\AFRC5500-G-101.dgn

9/11/2012

9:18:20 AM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-G

-1 .d g n

/1

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

EXIT

PLAN

NORTH

EXIT LOCATION

EXIT SIGN

FIRE EXTINGUISHER (RECESSED WALL CABINET)

LEGEND

FIRE EXTINGUISHER (BRACKET MOUNTED)

CONSTRUCTION TYPE / USE GROUP / FIRE PROTECTION

CONSTRUCTION TYPE (IBC 2006 SECTION 602.2):

TYPE 2B - UNPROTECTED NONCOMBUSTIBLE

A3 ASSEMBLY (ACCESSORY USE; SECTION 508.3.1)

(FULLY SPRINKLED)

FIRE PROTECTION SYSTEM(S):

AUTOMATIC SPRINKLERS:

USE GROUP (IBC 2006):

BUILDING HEIGHT: (IBC 2006 TABLE 503)

ACTUAL HEIGHT:

ALLOWABLE HEIGHT: 3 STORY, 55 FEET

2 STORY, 42 FEET

ALLOWABLE AREA:

Tabular Area - per floor (Table 503)

Frontage Increase (506.2) = 75%

PLAN AREA DATA (S1 USE GOVERNS)

BUILDING & STRUCTURE ELEMENTS: (IBC 2006 TABLE 601

FIRE RESISTANCE RATINGS : (IBC CHAPTER 7)

COLUMNS

SHAFTS

FLOOR CONSTRUCTION

ROOF CONSTRUCTION

ELEVATOR ENCLOSURES

LOAD BEARING WALLS

HORIZONTAL EXIT

EXIT ENCLOSURES:

EXIT CORRIDORS

EXIT PASSAGEWAY

STAIR ENCLOSURES

1 HOUR

1 HOUR

1 HOUR

0 HOURS

0 HOURS*

0 HOURS

0 HOURS

0 HOURS

1 HOUR

2 HOUR

3 STORIES OR LESS: ALLOWABLE AREA - per floor

Sprinkler Increase (506.3) = 200%

S.F. AREA:

17,500

35,000

65,625

41,916ACTUAL AREA - per floor (1st floor worst case)

73,080ACTUAL AREA - Total Building

*NOTE: The rating of the building structure can not be less than the assembly it supports.

APPLICABLE CODES

TRAVEL DISTANCE:

TRAVEL DISTANCES (NFPA 101)

TRAVEL DISTANCE

B BUSINESS (SECTION 304)

NON-SEPARATED MIXED USE (SECTION 508.3.2)

ELEVATOR ROOM 2 HOUR

OCCUPANCY

ASSEMBLY

BUSINESS

STORAGE

250 FEET

300 FEET

400 FEET

DEAD ENDS:

DEAD END LENGTHOCCUPANCY

ASSEMBLY

BUSINESS

STORAGE

20 FEET

50 FEET

100 FEET

COMMON PATH OF TRAVEL:

COMMON PATHOCCUPANCY

ASSEMBLY (>50 OCCUPANTS)

BUSINESS

STORAGE

20 FEET

100 FEET

100 FEET

ASSEMBLY (<50 OCCUPANTS) 75 FEET

ALLOWABLE AREA - Total Building 131,250

S1 MODERATE HAZARD STORAGE (SECTION 311)

USE GROUP S-1

USE GROUP B

ACCESSORY USE GROUP A-3

169’

131’

40’ 40’

158’

191’

13,125

1 HOUR FIRE BARRIER - UL 495

2 HOUR FIRE BARRIER - UL417, UL495

1 HR FIRE BARRIER UL #U495

1 HR FIRE BARRIER UL #U495

1 HR FIRE BARRIER UL #U495

1 HR FIRE BARRIER UL #U417

OCCUPANCY:

OFFICE

LOCKER ROOM

MECH/ELEC/STORAGE

TOTAL

AREA:

3,243

2,588

1,165

2,332

9,428

ROOMS W/ INDIVIDUAL

EXITS

TOTAL

LOAD

FACTOR:

OCCUPANT

LOAD:

20 SF/PERSON

100 SF/PERSON

50 SF/PERSON

300 SF/PERSON

OCCUPANCY:

WEAPONS SIMULATOR

ASSEMBLY HALL

ELECTRICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

ELECTRICAL ROOM

AREA:

LOAD

FACTOR:

OCCUPANT

LOAD:

1,480 20 SF/PERSON 74

520 300 SF/PERSON 2

1,527 300 SF/PERSON 6

96 300 SF/PERSON 1

1,530 20 SF/PERSON 77

3,652 15 SF/PERSON 243

161 300 SF/PERSON 1

168 300 SF/PERSON 1

15,700 300 SF/PERSON 52

OCCUPANT LOAD (NFPA 101 TABLE 7.3.1.2)

EF

TOTAL

AREA:

LOAD

FACTOR:

OCCUPANT

LOAD:

OCCUPANCY:

2,995 300 SF/PERSON 7MECH/ELEC/STORAGE

20,849 100 SF/PERSON 192OFFICE

TOTAL 238

EXIT CAPACITY (NFPA 101 TABLE 7.3.3.1)

FIRE AREA: SINGLE

CLEAR

WIDTH:

CAPACITY

FACTOR:

EXIT

CAPACITY:EXIT LOCATION:

136 INCHES 0.2 IN/PERSON

TYPICAL DOUBLE

DOORS (2) 680

CLEAR

WIDTH:

CAPACITY

FACTOR:

EXIT

CAPACITY:EXIT LOCATION:

68 INCHES 0.2 IN/PERSON

68 INCHES 0.2 IN/PERSON

136 INCHES 0.2 IN/PERSON 680

68 INCHES 0.2 IN/PERSON 340

TOTAL 3,220

CLEAR

WIDTH:

CAPACITY

FACTOR:

EXIT

CAPACITY:

EXIT LOCATION:

60 INCHES 0.3 IN/PERSONSTAIR A

46 INCHES 0.3 IN/PERSONSTAIR B

TOTAL

MIN. NUMBER OF EXITS: <500 OCCUPANTS = 2 (NFPA 7.4.1.2)

MIN. NUMBER OF EXITS: 500 - 1000 OCCUPANTS = 3 (NFPA 7.4.1.2)

UNIT STORAGE

WEAPONS SIMULATOR

MECHANICAL ROOM

MECHANICAL ROOM

EF

ASSEMBLY HALL

ELECTRICAL ROOM

ELECTRICAL ROOM

UNIT STORAGE

68 INCHES 0.2 IN/PERSON 340

68 INCHES 0.2 IN/PERSON 340

68 INCHES 0.2 IN/PERSON 340

32 INCHES 0.2 IN/PERSON 160

68 INCHES 0.2 IN/PERSON 340

FIRST FLOOR OCCUPANT LOAD

FIRST FLOOR OCCUPANT LOAD OF ROOMS W/ INDIVIDUAL EXITS

SECOND FLOOR OCCUPANT LOAD

EXIT CAPACITY OF ROOMS W/ INDIVIDUAL EXITS

FIRST FLOOR EXIT CAPACITY

SECOND FLOOR EXIT CAPACITY

CODE / LIFESAFETY DATA - TRAINING BUILDING

32’8’

SCALE:1/16"=1’’-0"

0 16’

FEC

FEC

FEFE

164’

189’

FE

FEC

FE

FEC

FEC

FE

FE

FE

FE

FE

FE

FE

E X

IT

E X

IT

E X

IT

E X

IT

E X

IT

EXIT

E X

IT

EXIT

EXIT

EXIT

EXIT

E X

IT

EXIT

E X

IT

E X

IT

E X

IT

CLASSROOM/LEARNING

STAIRS FROM SECOND

FE

FEC

BREAK AREA 279 15 SF/PERSON 19

CLASSROOMS/LEARNING (2)

CLASSROOM/LEARNING

EXIT LOAD (OCCUPANTS)

TRAVEL DISTANCE

OCCUPANT LOAD25

24 24

UFC 1-200-01; GENERAL BUILDING REQUIREMENTS

UFC 3-600-01; FIRE PROTECTION ENGINEERING FOR FACILITIES

UFC 4-010-01; MINIMUM ANTI TERRORISM STANDARDS

IBC 2006; INTERNATIONAL BUILDING CODE

NFPA 101 2009; LIFE SAFETY CODE

ADAAG; ADA ACCESSIBILITY GUIDELINES

DASHED OUTLINE INDICATES COLUMNS

TO RECEIVE 1 HR FIRE PROOFING UL

#X772 TYPICAL OF (4) (1ST FLOOR TO

UNDERSIDE OF 2ND FLOOR ONLY)

DASHED OUTLINE INDICATES COLUMNS

TO RECEIVE 1 HR FIRE PROOFING UL

#X772 TYPICAL OF (6) (1ST FLOOR TO

UNDERSIDE OF 2ND FLOOR ONLY)

BOLD LINES INDICATE EXTENT OF

STRUCTURAL FLOOR BEAMS TO RECEIVE

1 HR FIRE PROOFING - UL #D847

BOLD LINES INDICATE EXTENT OF

STRUCTURAL FLOOR BEAMS TO RECEIVE

1 HR FIRE PROOFING - UL #D847

INCIDENTAL USE: STORAGE ROOMS > 100 S.F., BOILER ROOMS, REFRIGERATION

COMPARTMENT ROOMS AND MECHANICAL ROOMS MAY BE EXCUSED WITH SMOKE

PARTITIONS IF BUILDING IS FULLY SPRINKLED

SMOKE

ENCLOSURE

SMOKE

ENCLOSURE

SMOKE

ENCLOSURE

SMOKE

ENCLOSURE

SMOKE BARRIER

21 2.7 3 3.2 4 5 6 6.4 7 7.8 8 9 10

1 2 3 3.2 4 5 6 6.4 7 7.8 8 9 10

A

B

C

D

E

A

B

C

D

D.1

E

D.6

2.7

116B

VAULT

STAGING

122A

ASSEMBLY

HALL / DRILL HALL

A

STAIR

119B

TER.

116A

ARMORY

129A

DIST. LEARNING

102A

MAIL DISTRIBUTION

FAMILY SUPPORT

111A

CLASSROOM

111B

112A

112B

SIPRNET CAFE

TRNG AIDS

LOBBY

127A

WOMEN

106B

CORR

106C

106A

106E

106F

123B

CONTROL RM.

117D

OFFICE

117C

OFFICE

109A

LIBRARY

READING ROOM

109B

RAPIDS OFF

126B

MENS LOCKERS

127B

LOCKER

102B

MAIL SCAN

102C

MAIL

SCAN VESTIBULE

UNIT STOR

118A

ELEC

118B

ELEC

119A

ENT FACILITY

121A

MECH

121B

MECH

FOOD STORAGE

JANITOR

ELEVATOR RM.

129B

REC/RET OFF

101A

FAC MANAGER

117B

338 OFFICE

SUPPLY OFF

117A

HQ. 223

126A

MEN

122B

CHAIR STOR

100A

VESTIBULE

100B

VESTIBULE

B

STAIR

106D

A

ELEVATOR

LRNG CTR

123C

CONTROL

ROOM STORAGE

123A

WEAPONS SIMULATOR

File details come from the government source that posted it. Updated .