AF17A7-1.PDF

PDF 1 MB Posted

Attached to
PA 206 HORSHAM HVAC SYSTEMS REPAIRS
Solicitation number
W912BU24R0001
Issued by

About this file

This document contains a reflected ceiling plan for an Army Reserve Training Center and related federal contract opportunity for HVAC system repairs. The ceiling plan provides details on ceiling heights, lighting fixtures, sprinkler heads, and other components for the various rooms in the training facility. The related federal contract opportunity is a special notice from the Department of the Army Corps of Engineers seeking HVAC repairs for building PA 206 at Horsham, Pennsylvania. The solicitation number is W912BU24R0001 and is titled "PA 206 Horsham HVAC Systems Repairs." No further information is provided on response dates, pricing terms, or other procurement details.

View the file

Other files

File Type Posted
W912BU24R0001 Amendment 0009_Cancellation.pdf PDF
W912BU24R0001 Amendment 0005.pdf PDF
10-M-800.pdf PDF
AF85D7-1.PDF PDF
AFA040-1.PDF PDF
00-M-806.pdf PDF
AF0F76-1.PDF PDF
00-MP-4.PDF PDF
AF6B67-1.PDF PDF
10-M-803.pdf PDF
AFDA0C-1.PDF PDF
00-M-201.pdf PDF
AF7DA6-1.PDF PDF
AF5B0D-1.PDF PDF
AF4200-1.PDF PDF
10-MH-1.PDF PDF
AF2EB8-1.PDF PDF
AF7BD0-1.PDF PDF
AF4273-1.PDF PDF
00-M-803.pdf PDF
10-M-801.pdf PDF
00-MP-2.PDF PDF
AF1533-1.PDF PDF
AF9D68-1.PDF PDF
AFC2EA-1.PDF PDF
AF2AEE-1.PDF PDF
AFD99B-1.PDF PDF
AF26AC-1.PDF PDF
W912BU24R0001 Amendment 0004.pdf PDF
AFFB36-1.PDF PDF
00-M-807.pdf PDF
00-M-808.pdf PDF
AF9FDC-1.PDF PDF
AF47CB-1.PDF PDF
AFRC55-2.PDF PDF
00-M-802.pdf PDF
AFFC3F-1.PDF PDF
AFC8A7-1.PDF PDF
AF8E75-1.PDF PDF
AFD903-1.PDF PDF
AF54B2-1.PDF PDF
AFD078-1.PDF PDF
00-MH-1.PDF PDF
AF0EF7-1.PDF PDF
00-MP-1.PDF PDF
00-M-805.pdf PDF
00-MH-4.PDF PDF
AF377B-1.PDF PDF
AF9D55-1.PDF PDF
AFE9FE-1.PDF PDF
Show 40 more

Latest 50 of 102 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

00-A-111

1/16" = 1’ 0" A4

OVERALL FIRST FLOOR REFLECTED CEILING PLAN

T R

A

IN

IN

G C

E N

T E

R O

V E

R A

L L F

IR

S T F

L O

O R

R E

F L E

C T

E D C

E

IL

IN

G P

L A

N

AS-BUILT

S:\USACE_Projects\6-609-063_AFRC-Willow_Grove_PA\Con_Docs\CAD_Sheets\Architectural\AFRC5500-A-111.dgn

5/30/2013

4:20:36 PM

rifem

F O

R U

M S

T U

D

IO

I

N N

E R

B E

L T B

U S

IN

E S

S C

E N

T E

R D

R

S T L

O U

IS

M O

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T N

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

SHEET OF

fi

US Army Corps of Engineers

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

L O

U

IS

V

IL

L E D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K Y

GENERAL NOTES

KEY PLAN

KEY NOTES

GRAPHIC SCALE

32’8’

SCALE:1/16"=1’

0 16’

F S

B A

Z

C L

A Y

C O C

O N

S T

R U

C T

IO

N

.1

.1

-W

Q R -0

-R -0

P -1

1 3

C O

N C

E P

T D

E S

IG

N S

U B

M

IT

T A

L .1

.0

.1

.0

R

E V

IS

E D C

H A

R R

E T

T E C

O N

C E

P T S

U B

M

IT

T A

L

IN

T

E R

IM

S

U B

M

IT

T A

L .1

.1

.2

.1

A F

R C

-A -1

.d g n

/3

/2

F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L

A R

M Y R

E S

E R

V E T

R A

IN

IN

G C

E N

T E

R W

IL

L O

W G

R O

V E N

A V

A L A

IR

S

T A

T

IO

N W

Q R -0

-C -0

H O

R S

H A

M P

A

C

O R

R E

C T

E D F

IN

A L D

E S

IG

N S

U B

M

IT

T A

L .0

.1

.1

.1

C

E R

T

IF

IE

D F

IN

A L S

U B

M

IT

T A

L

B R

IC

E Z

IC

K U

H R

REFLECTED CEILING LEGEND

8’-8"

R

CEILING TAG

PROJECTION SCREEN

CAN LIGHT

SUSPENDED LIGHT

FIXTURE

SURFACE MOUNTED

LIGHT FIXTURE

UPRIGHT

SPRINKLER

HEAD

SPRINKLER

HEAD

LAY IN

LIGHT

FIXTURE

RETURN/

EXHAUST

SUPPLY

PROJECTOR

ACOUSTICAL

CEILING TILE

GYP. BOARD

CEILING

SEE FIRE PROTECTION, MECHANICAL, PLUMBING AND ELECTRICAL

DRAWINGS FOR FURTHER INFORMATION

1. ALL CEILINGS ON THE FIRST FLOOR OF THE TRAINING BUILDING TO

BE 8’-8" A.F.F., U.N.O.

2. ALL CEILINGS ON THE SECOND FLOOR OF THE TRAINING BUILDING

TO BE 8’-8" A.F.F., U.N.O.

3. ALL CEILINGS IN THE OMS / AMSA BUILDING TO BE 8’-8" A.F.F.,

U.N.O.

4. REFER TO THE ELECTRICAL AND MECHANICAL DRAWINGS FOR THE

LIGHTING AND DIFFUSER LAYOUT.

5. ALL BULKHEADS ARE TO BE TYPE 2A / T, SEE REFLECTED CEILING

PLANS FOR HEIGHTS.

6. PROJECTION SCREENS AND PROJECTORS ARE SHOWN FOR

LOCATION SUGGESTION ONLY, SEE ELECTRICAL DRAWINGS FOR

FINAL LOCATIONS.

7. ALL CEILINGS NOTED AS O.T.S. (OPEN TO STRUCTURE) SHALL BE PAINTED

1 2 3 4 5 6 6.4 7 7.8 8 9 10

A

B

C

D

D.1

E

D.6

2.7 3.2

M A

T C

H L

IN

E

A

-A -1

M A

T C

H L

IN

E

A

-A -1

PLAN

NORTH

116B

VAULT

STAGING

122A

ASSEMBLY

HALL / DRILL HALL

A

STAIR

119B

TER.

116A

ARMORY

129A

DIST. LEARNING

102A

MAIL DISTRIBUTION

FAMILY SUPPORT

111A

CLASSROOM

111B

112A

112B

SIPRNET CAFE

TRNG AIDS

LOBBY

127A

WOMEN

106B

CORR

106C

106A

106E

106F

123B

CONTROL RM.

117D

OFFICE

117C

OFFICE

109A

LIBRARY

READING ROOM

109B

RAPIDS OFF

126B

MENS LOCKERS

127B

LOCKER

102B

MAIL SCAN

102C

MAIL

SCAN VESTIBULE

UNIT STOR

118A

ELEC

118B

ELEC

119A

ENT FACILITY

121A

MECH

121B

MECH

FOOD STORAGE

JANITOR

ELEVATOR RM.

129B

REC/RET OFF

101A

FAC MANAGER

117B

338 OFFICE

SUPPLY OFF

117A

HQ. 223

126A

MEN

122B

CHAIR STOR

100A

VESTIBULE

100B

VESTIBULE

B

STAIR

106D

ELEVATOR

LRNG CTR

123C

CONTROL

ROOM STORAGE

123A

WEAPONS SIMULATOR

F

F

F

F

F

FF

F

F

F

F

F

AAAAA

A A A A A

AAAA

A

CCCCC

C C C C C

CCCC

C

T N

A C

TNAC

TNAC

FACP

S

S

S S

S

S

S

S

S

S

S

S

P

PPP

P

P

P

S

S

P

S

S

SSSSS

S

S

S

S S S

S

S

S

SS

S

S

S

S

S

S

C

A

C

A

C

A

C A

CA

C

A

C

A

C A

C A

C

A

CA

C A

C A

CA

C

A

C A

C

A

C A

C

A

C A

CA

C A

C A

CA

CA

CA

C

A

CA

C A

C

A

C

A

C

A

C

A

S

S

S

S

S

S

S

S

L O

C

L O

C

F

S

S

S

S

P

S

S

S

S

S

S

S

S

S

LOC

S

F

F

F

S

S

C

File details come from the government source that posted it. Updated .