FJRP159073-M-302-Amd03.pdf

PDF 420 KB Posted

Attached to
C-17 Refueling Hydrant System Ramp Expansion
Solicitation number
W91242-18-R-0002
Issued by

View the file

Other files

File Type Posted
Questions_and_Answers_96-101__W91242-18-R-0002.pdf PDF
FJRP159073-CG104-Amendment_0007.pdf PDF
FJRP159073-CG103-Amendment_0007.pdf PDF
Amendment_0007.pdf PDF
33_52_43.28_Amd03.pdf PDF
Questions_and_Answers_78-95__W91242-18-R-0002.pdf PDF
Revised_33_52_80_Amendment_0006.pdf PDF
Revised_08_71_00_Amendment_0006.pdf PDF
Revised_33_52_43_Amendment_0006.pdf PDF
Revised_09_96_00_Amendment_0006.pdf PDF
Revised_09_97_13.27_Amendment_0006.pdf PDF
FJRP159073-A-201-Amendment_0006.pdf PDF
Revised_13_34_19_Amendment_0006.pdf PDF
W91242-18-R-0002_0006.pdf PDF
Revised_09_90_00_Amendment_0006.pdf PDF
FJRP159073-A-601-Amendment_0006.pdf PDF
Amendment_0005_Revised_01_45_00.pdf PDF
Amendment_0004_Section_0010_Price_Schedule.pdf PDF
Amendment_0005.pdf PDF
Questions_and_Answers_40-77__W91242-18-R-0002.pdf PDF
Revised_EXIBIT_H_Proposal_Price_Schedule_Amendment_0004.pdf PDF
Amendment_0004.pdf PDF
Questions_and_Answers_18-38__W91242-18-R-0002.pdf PDF
1._Drawings_-COVER_SHEET.pdf PDF
FJRP159073-M-002-Amd03.pdf PDF
FJRP159073-M-301-Amd03.pdf PDF
FJRP159073-GC-003-Amd03.pdf PDF
32_05_33_Amd03.pdf PDF
FJRP159073-EI-503-Amd03.pdf PDF
Exhibit_F_Small_Business_Participation_Format.pdf PDF
33_09_53_Amd03.pdf PDF
FJRP159073-MS502-Amd03.pdf PDF
FJRP159073-CS-121-Amd03.pdf PDF
FJRP159073-MS504-Amd03.pdf PDF
FJRP159073-M-401-Amd03.pdf PDF
FJRP159073-M-512-Amd03_(1).pdf PDF
33_52_43.13_Amd03.pdf PDF
FJRP159073-EP-101-Amd03.pdf PDF
Exhibit_G_-_Subcontracting_Plan_Format.pdf PDF
33_52_43.11_Amd03.pdf PDF
FJRP159073-EI-602-Amd03.pdf PDF
FJRP159073-C-511-Amd03.pdf PDF
FJRP159073-M-003-Amd03.pdf PDF
FJRP159073-MD902-Amd03.pdf PDF
FJRP159073-MS503-Amd03.pdf PDF
FJRP159073-C-510-Amd03.pdf PDF
FJRP159073-CU-121-Amd03.pdf PDF
FJRP159073-CU-224-Amd03.pdf PDF
W91242-18-R-0002_0003.pdf PDF
FJRP159073-M-502-Amd03.pdf PDF
Show 40 more

Latest 50 of 114 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S c a l e

F o r

M i c r o f i l m i n g

I n c h e s

M i l l i m e t e r s date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

NORTH CAROLINA AIR NATIONAL GUARD

DOUGLAS INTERNATIONAL AIRPORT

CHARLOTTE, NORTH CAROLINA

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

Project No. - FJRP159073

C-17 TYPE III HYDRANT

REFUELING SYSTEM/

RAMP EXPANSION

94893

C O

P Y

R I G

H T

B U

R N

S

M c D

O N

N E

L L

E

N G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

D

2 3

C

4 5

A

B

MECHANICAL

SECTIONS 2 OF 3

FJRP159073-M-302.DWG

R.PERUEB.COOVER

V.KEEBLE

M-302

GENERAL NOTE: THIS DRAWING ONLY

1. REFER TO DRAWINGS M-001 AND M-002 FOR

LEGENDS, ABBREVIATIONS AND GENERAL

PROJECT NOTES.

2. ALL LARGE BORE MANUAL VALVES

LOCATED 72 INCHES OR HIGHER ABOVE

FINISHED FLOOR SHALL BE PROVIDED WITH

CHAIN OPERATORS.

3. PROVIDE INSULATING FLANGE KITS AT ALL

CARBON STEEL TO STAINLESS STEEL

TRANSITIONS.

4. PROVIDE FBE COATING A MINIMUM OF 6

INCHES BEYOND TRANSITION FROM BELOW

GRADE TO ABOVE GRADE PIPING.

5. REFER TO DIFFERENTIAL PRESSURE

TRANSMITTER DETAIL A1/M-514 AND

RETURN VENTURI DETAIL C1/M-514.

6. REFER TO S-551 TO S-555 FOR PIPE

SUPPORT DETAILS.

C1

SECTION

SCALE: 3/8"=1'-0"

6'

SCALE IN FEET

0 2' 4'

A1

SECTION

SCALE: 3/8"=1'-0"

6'

SCALE IN FEET

0 2' 4'

6'

SCALE IN FEET

0 2' 4'

10" CS

10" CS

SURGE ARRESTOR

TANK (TYP OF 2)

8" MOV BALL

VALVE

10"x6" REDUCER

(TYP OF 2)

6" BALL

VALVE (FB)

6" RETURN

VENTURI

(SEE NOTE 5)

PS-2

PS-2

PS-2

6" BPCV-1

6" BALL

VALVE

(FB)

8"x6"

RED

6" CS SUPPLY TO HHT

CHECKOUT STAND,

SEE NOTE 4

8" D/FV-1

8" BALL

VALVE

8" BALL

VALVE

10" CS

8" CS

6" CS

C

S

6" SS FROM EXISTING

TRUCK OFFLOAD,TIE-IN

(SEE NOTE 4)

8" DBB

PLUG

VALVE

6" DBB

PLUG

VALVE

6" BASKET

STRAINER

6" BALL

VALVE

C

S

C

S

8" CS

8" CS

8" BALL

VALVE

(NOTE 2)

8" DBB PLUG

VALVE W/

LIMIT SWITCH

(TYP OF 6)

10" DBB

PLUG VALVE

10" DBB

PLUG VALVE

12" CS

12" CS

8" CS TO

TK-1

8" CS TO

TK-3

8" CS TO

TK-2

8" CS8" CS

6" DBB

PLUG VALVE

12" CS

10" DBB

PLUG VALVE

FOR CONTINUATION

SEE CU228

FOR CONTINUATION

SEE CU227

FOR CONTINUATION

SEE CU227

C S

S S

PS-6

PS-2C

PS-2

PS-2

PS-5

PS-1

PS-5 PS-2

PS-2C

PS-2C

PS-2C

TRV

TRV

TRV

PG

MAV

PG

PG

PG

MAV

PT

MAV

MAV

M-512

B4

SURGE

ARRESTOR

TANK DETAIL

2" MOV

BALL

VALVE

PIT

DR

8"x6"

REDUCER

DR

DR

2" PCV-1

PT

2" SS DRAIN AND TRV

TRV

TRV

MAV

MAV

2" SS DRAIN AND TRV

2" SS F/S

SLOW FILL

2" SS DRAIN

AND TRV

2" SS DRAIN

AND TRV

2" SS TO PRT

INDICATES BID OPTION 3

PS-2

PS-2

DECEMBER 2016

8" CS RETURN FROM

HHTC STAND (NOTE 4)

5'-0" (MIN)

5'-0"

PS-2

PS-2C

PS-2

TRV

2" SS FROM PST'S

2" CS

FROM PRT

PG

SAMPLE

PORT

(BEHIND)

MAV

C S

S S

C S

S S

C S

S S

C S

S S

C S

S S

C S

S S

C S

S S

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

INIT

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text 10/13/17

AutoCAD SHX Text

B-3 FINAL SUBMITTAL

AutoCAD SHX Text

AutoCAD SHX Text 02/07/18

AutoCAD SHX Text

AMENDMENT 0003

AutoCAD SHX Text

AutoCAD SHX Text

BC

AutoCAD SHX Text

IF

AutoCAD SHX Text

IF

AutoCAD SHX Text

IF

AutoCAD SHX Text

BC

2018-02-07T15:14:58-0600
Coover, Bra

File details come from the government source that posted it.