Revised_08_71_00_Amendment_0006.pdf

PDF 69 KB Posted

Attached to
C-17 Refueling Hydrant System Ramp Expansion Federal contract opportunity
Solicitation number
W91242-18-R-0002
Issued by
Department of the Army North Carolina Army National Guard

About this file

Revised 08 71 00 Amendment 0006

View the file

Other files for this federal contract opportunity

Other files attached to C-17 Refueling Hydrant System Ramp Expansion, newest first.
File Type Posted
Questions_and_Answers_96-101__W91242-18-R-0002.pdf PDF
Amendment_0007.pdf PDF
FJRP159073-CG103-Amendment_0007.pdf PDF
33_52_43.28_Amd03.pdf PDF
Questions_and_Answers_78-95__W91242-18-R-0002.pdf PDF
FJRP159073-A-601-Amendment_0006.pdf PDF
Revised_33_52_80_Amendment_0006.pdf PDF
Revised_09_96_00_Amendment_0006.pdf PDF
Revised_09_97_13.27_Amendment_0006.pdf PDF
FJRP159073-A-201-Amendment_0006.pdf PDF
Amendment_0005.pdf PDF
Amendment_0005_Revised_01_45_00.pdf PDF
FJRP159073-MS503-Amd03.pdf PDF
01_33_29_Amd03.pdf PDF
FJRP159073-M-603-Amd03.pdf PDF
FJRP159073-B-101-Amd03_(1).pdf PDF
31_32_11_Amd03.pdf PDF
FJRP159073-CU-223-Amd03.pdf PDF
FJRP159073-GC-002-Amd03.pdf PDF
EXIBIT_H_Proposal_Price_Schedule.pdf PDF
FJRP159073-GC-001-Amd03.pdf PDF
SpecTOC_Amd03.pdf PDF
33_52_80_Amd03.pdf PDF
Exhibit_D_Letter_of_Commitment.pdf PDF
FJRP159073-MS501-Amd03.pdf PDF
FJRP159073-EI-503-Amd03.pdf PDF
FJRP159073-CS-121-Amd03.pdf PDF
Exhibit_G_-_Subcontracting_Plan_Format.pdf PDF
33_52_43.11_Amd03.pdf PDF
FJRP159073-EI-602-Amd03.pdf PDF
FJRP159073-M-502-Amd03.pdf PDF
FJRP159073-E-703-Amd03.pdf PDF
Exhibit_C_Past_Performance_Questionnaire_Package.pdf PDF
FJRP159073-ES-401-Amd03_(1).pdf PDF
03_30_00_Amd03.pdf PDF
Exhibit_B_Subcontractor_Consent_Form.pdf PDF
FJRP159073-EI-501-Amd03.pdf PDF
Questions_and_Answers_1-17__W91242-18-R-0002.pdf PDF
Pre-proposal_Conference_Sign_in_sheet.pdf PDF
1.3_Drawings-CIVIL_1_of_4.pdf PDF
1.6_Drawings-CATHODIC_PROTECTION.pdf PDF
Exhibit_F_Small_Business_Participation_Format.pdf PDF
Exhibit_G_-_Subcontracting_Plan_Format.pdf PDF
1.1_Drawings-INDEX_SHEET_(1).pdf PDF
1._Drawings_-COVER_SHEET.pdf PDF
1.5_Drawings-ARCHITECTURE.pdf PDF
6_-_SAP_SINGLE_SOURCE_DETERMINATION,_1_PGS.pdf PDF
1.7_Drawings-MECHANICAL.pdf PDF
8_-_PRE-PROPOSAL_SITE_VISIT_INSTRUCTIONS.pdf PDF
1.9_Drawings-FIRE_DETECTION.pdf PDF
Show all 50

C-17 Refueling Hydrant System Ramp Expansion has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C-17 Type III Fuel System & Ramp Expansion FJRP159073 145th Airlift Wing, North Carolina Air National Guard

Section 08 71 00 Page 1

SECTION 08 71 00

DOOR HARDWARE

02/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2004; R 2012) Determining the Rate of Air

Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2013) Butts and Hinges

ANSI/BHMA A156.13 (2012) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.16 (2013) Auxiliary Hardware

ANSI/BHMA A156.18 (2016) Materials and Finishes

ANSI/BHMA A156.21 (2014) Thresholds

ANSI/BHMA A156.22 (2012) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and

Holders

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 101 (2015; ERTA 2015) Life Safety Code

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for

Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

Section 08 71 00 Page 2

36 CFR 1191 Americans with Disabilities Act (ADA)

Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Hardware Schedule; G

Keying System

SD-03 Product Data

Hardware Items; G

SD-08 Manufacturer's Instructions

Installation

SD-11 Closeout Submittals

Key Bitting

1.3 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.4 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

1.5 KEY BITTING CHART REQUIREMENTS

Section 08 71 00 Page 3

1.5.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.6 QUALITY ASSURANCE

1.6.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.6.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.7 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule. Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal doors must be manufactured using a template.

Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 101 for exit doors, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph

HARDWARE SCHEDULE.

2.3 HARDWARE ITEMS

Section 08 71 00 Page 4

Clearly and permanently mark with the manufacturer's name or trademark, hinges, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1. Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.2 Locks and Latches

2.3.2.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13, Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges.

2.3.3 Exit Devices

Provide in accordance with ANSI/BHMA A156.3, Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices.

2.3.4 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

2.3.5 Keying System

Provide an extension of the existing keying system. Provide construction interchangeable cores.

2.3.6 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.6.1 Lever Handles

Provide lever handles. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that

Section 08 71 00 Page 5 specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.7 Keys

Furnish one file key, one duplicate key, and one working key for each key change. Furnish one additional working key for each lock of each keyed-alike group. Stamp each key with appropriate key control symbol and "U.S.

property - do not duplicate." Do not place room number on keys.

2.3.8 Door Bolts

Provide in accordance with ANSI/BHMA A156.16. Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3, Type 25.

2.3.9 Closers

Provide in accordance with ANSI/BHMA A156.4, Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

2.3.9.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.10 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8.

2.3.11 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6.

2.3.11.1 Sizes of Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors.

2.3.12 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16. Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.13 Thresholds

Provide in accordance with ANSI/BHMA A156.21. Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.14 Weatherstripping Gasketing

Section 08 71 00 Page 6

Provide in accordance with ANSI/BHMA A156.22. Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE. Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed 1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:

2.3.14.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.

2.3.14.2 Interlocking Type

Zinc or bronze not less than 0.018 inch thick.

2.3.14.3 Spring Tension Type

Spring bronze or stainless steel not less than 0.008 inch thick.

2.3.15 Rain Drips

Provide in accordance with ANSI/BHMA A156.22. Provide extruded aluminum rain drips, not less than 0.08 inch thick, factory primed finish. Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.

2.3.15.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.15.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.

2.3.16 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18. Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items

Section 08 71 00 Page 7 not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish. Match exposed parts of concealed closers to lock and door trim.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces. Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.

3.1.2 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves.

3.2 EXIT DOORS

Provide hardware in accordance with NFPA 101 for exit doors.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8, unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors.

Section 08 71 00 Page 8

3.4 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.5 HARDWARE SETS

Set 1.0

Door: 102A

Description: EXT CONTROL ROOM, PAIR

6 Hinge TA2714 4-1/2" x 4-1/2"

US26D MK

1 Removable Mullion

TYPE 22

[WSL980]

PC SA

1 Exit Device TYPE 1, FUNCTION 09 [WS

70 8804 ETJ]

US32D SA

1 Exit Device (exit only)

TYPE 1,

FUNCTION 01 [WS

- 8810]

US32D SA

2 Permanent core

SFIC

BEST to match base standard

US15 BE

2 Door Closer CO2021 [351 PS] EN SA

2 Door Stop L02131 [467] Black RO

1 Threshold J12190 [273x3AFG Pemkote

MSES25SS]

PE

1 Gasketing ROY164 [2891AS [head]]

PE

1 Gasketing [both jambs]

ROY164 [290AS

[jamb]]

PE

1 Rain Guard ROY936 [346C] PE

2 Sweep ROY416 [3452AV] PE

2 Kick Plate J102 [K1050 8"

X 2" LDW X 4BE

X CSK]

US32D RO

Section 08 71 00 Page 9

2 Astragal ROY154 S772D (mounting on mullion)

PE

1 Mort Cylinder 1E-74 (for mullion)

626 BE

Set 2.0

Door: 102B

Description: EXT CONTROL ROOM, SINGLE

3 Hinge TA2714 4-1/2" x 4-1/2"

US26D MK

1 Exit Device TYPE 1, FUNCTION 09 [WS

70 8804 ETJ]

US32D SA

1 Permanent core

SFIC

BEST to match base standard

US15 BE

1 Door Closer CO2021 [351 PS] EN SA

1 Door Stop L02131 [467] Black RO

1 Threshold J12190 [273x3AFG Pemkote

MSES25SS]

PE

1 Gasketing ROY164 [2891AS [head]]

PE

1 Gasketing [both jambs]

ROY164 [290AS

[jamb]]

PE

1 Rain Guard ROY936 [346C] PE

1 Sweep ROY416 [3452AV] PE

1 Kick Plate J102 [K1050 8"

X 2" LDW X 4BE

Set 3.0

Doors: 103

Description: INTERIOR, SINGLE

3 Hinge TA2714 4-1/2" x 4-1/2"

US26D MK

Section 08 71 00 Page 10

Set 3.0

1 Privacy w/ Indicator

F19 [PBR 8802FL

IND]

626 YA

1 Wall Stop L02251 [409] US32D RO

1 Coat Hook RM802 US26D RO

1 Closer CO2011 [R 7500] 689 NO

1 Kick Plate J102 [K1050 8"

X 2" LDW X 4BE

Set 4.0

Doors: 104

Description: EXT MECH, PAIR

6 Hinge TA2714 4-1/2" x 4-1/2"

US26D MK

2 Surface Bolt 580-8 US32D RO

1 Storeroom Lock SERIES 1000, F07 [70 8204

LW1J]

US26D SA

1 Permanent core

SFIC

BEST to match base standard

US15 BE

2 Door Closer CO2021 [351 PS] EN SA

2 Door Stop L02131 [467] Black RO

1 Threshold J12190 [273x3AFG Pemkote

MSES25SS]

PE

1 Gasketing ROY164 [2891AS [head]]

PE

1 Gasketing [both jambs]

ROY164 [290AS

[jamb]]

PE

1 Rain Guard ROY936 [346C] PE

2 Sweep ROY416 [3452AV] PE

1 Astragal ROY634 [P3572SP X S772D]

PE

2 Kick Plate J102 [K1050 8"

X 2" LDW X 4BE

Section 08 71 00 Page 11

Set 5.0

Doors: 105

Description: EXT STOR

3 Hinge TA2714 4-1/2" x 4-1/2"

US26D MK

1 Storeroom Lock SERIES 1000, F07 [70 8204

LW1J]

US26D SA

1 Permanent core

SFIC

BEST to match base standard

US15 BE

1 Door Closer CO2021 [351 PS] EN SA

1 Door Stop L02131 [467] Black RO

1 Threshold J12190 [273x3AFG Pemkote

MSES25SS]

PE

1 Gasketing ROY164 [2891AS [head]]

PE

1 Gasketing [both jambs]

ROY164 [290AS

[jamb]]

PE

1 Rain Guard ROY936 [ 346C] PE

1 Sweep ROY416 [3452AV] PE

-- End of Section --

PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 PRODUCT DATA
1.4 HARDWARE SCHEDULE
1.5 KEY BITTING CHART REQUIREMENTS
1.5.1 Requirements
1.6 QUALITY ASSURANCE
1.6.1 Hardware Manufacturers and Modifications
1.6.2 Key Shop Drawings Coordination Meeting

1.7 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
2.3 HARDWARE ITEMS
2.3.1 Hinges
2.3.2 Locks and Latches
2.3.2.1 Mortise Locks and Latches
2.3.3 Exit Devices
2.3.4 Cylinders and Cores
2.3.5 Keying System
2.3.6 Lock Trim
2.3.6.1 Lever Handles
2.3.7 Keys
2.3.8 Door Bolts
2.3.9 Closers
2.3.9.1 Identification Marking
2.3.10 Overhead Holders
2.3.11 Door Protection Plates
2.3.11.1 Sizes of Kick Plates
2.3.12 Door Stops and Silencers
2.3.13 Thresholds
2.3.14 Weatherstripping Gasketing
2.3.14.1 Extruded Aluminum Retainers
2.3.14.2 Interlocking Type
2.3.14.3 Spring Tension Type
2.3.15 Rain Drips
2.3.15.1 Door Rain Drips
2.3.15.2 Overhead Rain Drips

2.3.16 Special Tools

2.4 FASTENERS
2.5 FINISHES
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Weatherstripping Installation
3.1.1.1 Stop Applied Weatherstripping
3.1.1.2 Interlocking Type Weatherstripping
3.1.1.3 Spring Tension Type Weatherstripping

3.1.2 Threshold Installation

3.2 EXIT DOORS
3.3 HARDWARE LOCATIONS
3.4 FIELD QUALITY CONTROL
3.5 HARDWARE SETS