2"
SCHEDULE
DOOR PER 2"
4"
SC
H E
DU
LE
DO
OR
P
ER
2"
SCHEDULE
DOOR PER 2"
2"
SC
H E
DU
LE
DO
OR
P
ER
1.1 1.2NL-IN
DO
OR
P
ER
S
CH
ED
UL
E
SCHEDULE
DOOR PER
DO
OR
P
ER
S
CH
ED
UL
E
2'
- 1
1" 6"
6" 8"
SCHEDULE
DOOR PER
F
F-IN OH-S
SC
H E
DU
LE
DO
OR
P
ER
SCHEDULE
DOOR PER
3'
- 4
4'
- 0
3' - 4"
W1
2" TYP.
GLASS TYPES:
REFERENCE SPECIFICATION FOR GLASS TYPES
1 LOW-E INSULATED SAFETY GLAZING (1")
2 INSULATED LAMINATED (1")
GENERAL NOTES: ROOM FINISH SCHEDULE
REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR
EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.
REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING
DRAWINGS, AND ENLARGED PLAN DRAWINGS FOR ADDITIONAL
FINISH PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS
FOR COORDINATION OF BUILDING FINISHES TO BUILDING
SYSTEMS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING
HEIGHTS AND CEILING MATERIAL EXTENTS.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL
MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET
ACCESSORIES, MILLWORK, AND ANY OTHER WALL MOUNTED
OBJECT.
UNLESS NOTED OTHERWISE, ALL INTERIOR EXPOSED
STRUCTURAL STEEL TO BE PAINTED PE-1.
1.
2.
3.
4.
5.
6.
ALL INTERIOR DOORS/FRAMES AND INTERIOR SURFACE OF
EXTERIOR DOORS/FRAMES TO BE PA-2.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,
MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND CONDUITS
EXCEPT PRE-FINISHED LINER PANELS AND FOAM GENERATORS.
THE PAINT COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE
PROTECTION PIPING COLOR SHALL BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED TO MATCH
ADJOINING SURFACE UNLESS OTHERWISE REQUIRED BY CODE.
COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES ON
MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES,
OPERATING PARTS, LABELS OR WARNINGS.
7.
8.
9.
10.
11.
12.
GENERAL NOTES: THIS SHEET ONLY
DIMENSIONS GIVEN IN DOOR, WINDOW AND LOUVER
SIZE COLUMN ARE FINISHED OPENING DIMENSIONS.
REFERENCE DRAWING A-611 FOR EXTERIOR DOOR,
WINDOW AND LOUVER DETAILS.
REFERENCE DRAWING A-201 FOR EXTERIOR MATERIAL
LEGEND.
1.
2.
3.
DOOR FRAME
RE: DOOR
SCHEDULE
DOOR
RE: DOOR SCHEDULE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
SEALANT
DO
OR
H
EI
G H T
S E E
DO
OR
S
CH
ED
UL
E
FRAME WIDTH
SEALANT TYP.
BOTH SIDES
DOOR FRAME
RE: SCHEDULE
DOOR
RE: DOOR SCHEDULE
BATT INSULATION
2"
DO
OR
W
ID
TH
SE
E
DO
OR
S
CH
ED
UL
E
JAMB ANCHORS
3 PER JAMB MIN.
1/2" 1/2"
FRAME WIDTH
METAL STUD WALL
RE: FLOOR PLANS FOR
WALL TYPE
SEALANT TYP. BOTH
SIDES
DOOR FRAME
RE: DOOR SCHEDULE
DOOR
RE: DOOR SCHEDULE
METAL STUD WALL
RE: FLOOR PLANS FOR
WALL TYPE
BATT INSULATION
1/2"1/2"
2"
DO
OR
H
EI
GH
T
SE
E
DO
OR
S
CH
ED
UL
E
FRAME WIDTH
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
PY
R
IG
H
T
BU
R
N S
M
C D
O N
N
EL
L
EN
G
IN
EE
R
IN
G
C O
M
PA
N Y, IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
2/
/2
:5 7:
P
M
FJRP159073-A-601.dwg
A-601 94893
DOOR, WINDOW, LOUVER & ROOM FINISH
SCHEDULES
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME
ASSEMBLY
RATING
DETAIL
HARDWARE
SET REMARKS
SIZE
TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILLWIDTH HEIGHT
102A PR. 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 1.0 102B - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 2.0 102C - 3' - 4" 4' - 10" OH-S STL PREFIN STL PREFIN 3 HR C2/A-611 B2/A-611 A2/A-611 - 1 102D - 3' - 4" 4' - 10" OH-S STL PREFIN STL PREFIN 3 HR C2/A-611 B2/A-611 A2/A-611 - 1
103 - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - B2/A-601 B3/A-601 B5/A-601 3.0
104 PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 4.0
105 - 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 5.0
DOOR AND FRAME LEGEND
FINISH
FINISH PE-1* PAINT-EPOXY
FINISH PREFIN PREFINISHED
MATERIAL
MATERIAL HM HOLLOW METAL
SIZE
SIZE - SINGLE DOOR
SIZE PR PAIR OF DOORS
TYPE
TYPE F FLUSH
TYPE F-IN FLUSH INSULATED
TYPE NL-IN NARROW LITE INSULATED
TYPE OH-S COILING FIRE SHUTTER
* FIELD APPLY PER PAINT SPECIFICATION FOR APPLICABLE
SUBSTRATE AND EXPOSURE.
WINDOW SCHEDULE
QUANTITY TYPE
SIZE SILL
HEIGHT
DETAIL
WIDTH HEIGHT HEAD JAMB SILL
2 W1 3' - 4" 4' - 0" 3' - 4" C3/A-611 B3/A-611 A3/A-611
LOUVER SCHEDULE
QUANTITY TYPE
SIZE SILL
HEIGHT
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
1 L1 3' - 0" 2' - 0" 8' - 0" C4/A-611 B4/A-611 A4/A-611
NTSSCALE:C2 FRAME TYPES
NTSSCALE:C1 DOOR TYPES
SCALE: 1/4" = 1'-0"
WINDOW TYPE
0 2' 4' 8'
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL DESCRIPTION MANUF.
MODEL
NUMBER
PRODUCT
NUMBER COLOR REMARKS
BASE
RB-1 RESILIENT RUBBER BASE, 4" HIGH ROPPE - - DARK GRAY 150 STANDARD TOE PROFILE
RB-2 INTEGRAL RESILIENT RUBBER BASE,
4" HIGH
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD INTEGRAL TO RESILIENT SHEET
FLOORING
RB-3 INTEGRAL RESILIENT RUBBER BASE,
6" HIGH
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD INTEGRAL TO RESILIENT SHEET
FLOORING
CEILINGS
ACT-1 ACOUSTICAL CEILING TILE, 24" x 24" ARMSTRONG CIRRUS
TEGULAR
584 WHITE
EXP EXPOSED - - - - PAINT PE-1
GWB GYPSUM WALL BOARD - - - - PAINT PE-1
MR GWB MOISTURE RESISTANT GYPSUM
WALL BOARD
- - - - PAINT PE-1
PE-1 PAINT - EPOXY - CEILING SHERWIN WILLIAMS - - WHITE
FLOORING
CS-1 CONCRETE - SEALED - - - -
PE-2 EPOXY - HIGH PERFORMANCE
COATING
- - - - SLIP-RESISTANT; SEE
SPECIFICATION SECTION 09 96
00 HIGH PERFORMANCE
COATINGS
RF-1 RESILIENT FLOORING -
HOMOGENEOUS VINYL SHEET
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD
WALLS
FRP-1 FIBERGLASS REINFORCED PANEL MARLITE INDURO FRP - D381 FASHION GREY
PA-1 PAINT SHERWIN WILLIAMS - - AGREEABLE GRAY
SW7029
PA-2 PAINT SHERWIN WILLIAMS - - DOVETAIL SW7018 METAL DOORS & FRAMES
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR
BASE WALLS
CEILINGMATERIAL NORTH EAST SOUTH WEST
101 PUMP ROOM PE-2 - - - - - -
102 CONTROL ROOM RF-1 RB-2 PA-1 PA-1 PA-1 PA-1 ACT-1
103 MEN'S/WOMEN'S TOILET RF-1 RB-3 FRP-1 FRP-1 FRP-1 FRP-1 MR GWB
104 MECH ROOM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 EXP
105 STORAGE CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 GWB
B1
0 3" 6" 9"SCALE: 3" = 1'-0"B5 DOOR SILL
SCALE: 3" = 1'-0"B3 DOOR JAMB
SCALE: 3" = 1'-0"B2 DOOR HEAD
0 3" 6" 9"0 3" 6" 9"
1. MANUALLY OPERATED COILING FIRE SHUTTER W/ FUSIBLE
LINK BOTH SIDES OF WALL. LOCATE FUSIBLE LINK 12 INCHES
FROM THE CEILING.
DOOR SCHEDULE REMARKS:
0 10/13/17 B-3 FINAL SUBMITTAL LS
1 02/22/18 AMENDMENT 000
| Sheets |
| A-601 - DOOR, WINDOW, LOUVER & ROOM FINISH SCHEDULES |