This document provides specifications for toilet accessories to be installed as part of a latrine annex construction project for the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis. Key products required include grab bars, glass mirrors, tilt mirrors, paper towel dispensers, waste receptacles, and toilet tissue dispensers. Specifications cover materials, finishes, dimensions, performance standards, warranties, and installation requirements for these toilet accessories. The related federal contract opportunity is to construct the latrine annex building in accordance with the specifications, drawings, and statement of work for the project.
View the file
Other files for this federal contract opportunity
Show all 50
Construct Latrine Annex Building has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Annex Addition to B3010
SECTION 10 28 13 Page 1
SECTION 10 28 13
TOILET ACCESSORIES
07/06
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM C 1036 (2006) Standard Specification for Flat Glass
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data
Finishes; G
Accessory Items; G
Manufacturer's descriptive data and catalog cuts indicating materials of construction, fasteners proposed for use for each type of wall construction, mounting instructions, operation instructions, and cleaning instructions.
SD-04 Samples
Finishes; G
Accessory Items; G
One sample of each accessory proposed for use. Incorporate approved samples into the finished work, provided they are identified and their locations noted.
SD-07 Certificates
Accessory Items
Certificate for each type of accessory specified, attesting that the items meet the specified requirements.
1.3 DELIVERY, STORAGE, AND HANDLING
Wrap toilet accessories for shipment and storage, then deliver to the jobsite in manufacturer's original packaging, and store in a clean, dry area protected from construction damage and vandalism.
1.4 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a 1 year period.
SECTION 10 28 13 Page 2
PART 2 PRODUCTS
2.1 MANUFACTURED UNITS
Provide toilet accessories shall be provided where indicated in accordance with paragraph SCHEDULE. Provide each accessory item shall be complete with the necessary mounting plates of sturdy construction with corrosion resistant surface.
2.1.1 Anchors and Fasteners
Provide anchors and fasteners capable of developing a restraining force commensurate with the strength of the accessory to be mounted and suited for use with the supporting construction. Provide oval heads exposed fasteners with finish to match the accessory.
2.1.2 Finishes
Except where noted otherwise, provide the following finishes on metal:
Metal Finish
Aluminum No. 4 satin finish
Stainless steel No. 4 satin finish
2.2 ACCESSORY ITEMS
Conform to the requirements for accessory items specified below.
2.2.1 Omitted
2.2.2 Grab Bar (GB)
Provide an 18 gauge, 1-1/4 inch grab bar OD Type 304 stainless steel.
Provide form and length for grab bar as indicated. Provide concealed mounting flange. Provide grab with satin finish or peened non-slip surface.
Furnish installed bars capable of withstanding a 2.225 kN ( 500 pound) vertical load without coming loose from the fastenings and without obvious permanent deformation. Allow 38 mm( 1-1/2 inch) space between wall and grab bar.
2.2.3 Mirrors, Glass (MG)
Provide Type I transparent flat type, Class 1-clear glass for mirrors.
Glazing Quality q1 6 mm( 1/4 inch) thick conforming to ASTM C 1036. Coat glass on one surface with silver coating, copper protective coating, and mirror backing paint. Provide highly adhesive pure silver coating of a thickness which provides reflectivity of 83 percent or more of incident light when viewed through 6 mm( 1/4 inch) thick glass, free of pinholes or other defects. Provide copper protective coating with pure bright reflective copper, homogeneous without sludge, pinholes or other defects, of proper thickness to prevent "adhesion pull" by mirror backing paint.
Provide mirror backing paint with two coats of special scratch and abrasion-resistant paint and baked in uniform thickness to provide a protection for silver and copper coatings which will permit normal cutting and edge fabrication.
SECTION 10 28 13 Page 3
2.2.4 Mirror, Tilt (MT)
Provide surface mounted tilt mirror with full visibility for persons in a wheelchair. Furnish adjustable tilt mirror, extending at least 100 mm( 4 inch) from the wall at the top and tapering to 25 mm( 1 inch) at the bottom.
Provide size in accordance with the drawings. Conform to ASTM C 1036 and paragraph Glass Mirrors.
2.2.5 Paper Towel Dispenser – see schedule on drawings.
2.2.6 Waste Receptacles – see schedule on drawings.
2.2.7 Toilet Tissue Dispenser – see schedule on drawings.
2.2.8 Other accessories as shown on schedule on drawings.
PART 3 EXECUTION
3.1 INSTALLATION
Provide the same finish for the surfaces of fastening devices exposed after installation as the attached accessory. Provide oval exposed screw heads.
Install accessories at the location and height indicated. Protect exposed surfaces of accessories with strippable plastic or by other means until the installation is accepted. After acceptance of accessories, remove and dispose of strippable plastic protection. Coordinate accessory manufacturer's mounting details with other trades as their work progresses.
Use sealants for brackets, plates, anchoring devices and similar items in showers (a silicone or polysulphide sealant) as they are set to provide a watertight installation. After installation, thoroughly clean exposed surfaces and restore damaged work to its original condition or replace with new work.
3.1.1 (not used)
3.1.2 Surface Mounted Accessories
Mount on concealed back-plates, unless specified otherwise. Conceal fasteners on accessories without back-plates. Install accessories with sheet metal screws or wood screws in lead-lined braided jute, teflon or neoprene sleeves, or lead expansion shields, or with toggle bolts or other approved fasteners as required by the construction. Install back-plates in the same manner, or provide with lugs or anchors set in mortar, as required by the construction. Fasten accessories mounted on gypsum board and plaster walls without solid backing into the metal or wood studs or to solid wood blocking secured between wood studs, or to metal back-plates secured to metal studs.
3.2 CLEANING
Clean material in accordance with manufacturer's recommendations. Do mot use alkaline or abrasive agents. Take precautions to avoid scratching or marring exposed surfaces.