This document is a field structural repair record template to be used for damage assessments and repairs to Stryker vehicles. It requires documentation of hull damage locations, descriptions of repairs performed, welding equipment and parameters used, and materials utilized. Repairs covered under this record include small cracks, weld cover gouges up to 1/8 inch deep and 8 square inches, removal and replacement of individual tapping pads, footman loops, and specific axle and differential mounts. The related federal contract opportunity notice indicates the US Army intends to issue a sole source, 5-year requirements contract to General Dynamics Land Systems for Stryker vehicle retrofit, reset/refurbishment, and damage repair services, with a forecasted quote due date of 30 September 2018.
Attachment 0035
View the file
Other files
Show 40 more
Latest 50 of 70 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rev (NR) Jun 4, 2009, Rev (1) April 12, 2012 Field Structural Repair Record MCDL # 256, DCN 801Page | 1 Page | 1 Page | 1
HULL #
LOCATION
DATE
WELDER/INSPECTOR
1. AREA OF DAMAGE
| |_| ROOF | |_| REAR WALL | |_| REAR LOWER HULL LEFT SIDE | ||||
| |_| UPPER NOSE | |_| SPONSON LEFT SIDE | |_| REAR LOWER HULL RIGHT SIDE | ||||
| |_| LOWER NOSE | |_| SPONSON RIGHT SIDE | |_| FLOOR LEFT FRONT SIDE | ||||
| |_| LEFT SIDE WALL | |_| FRONT LOWER HULL LEFT SIDE | |_| FLOOR RIGHT FRONT SIDE | ||||
| |_| RIGHT SIDE WALL | |_| FRONT LOWER HULL RIGHT SIDE | |_| FLOOR MID SECTION LEFT SIDE | ||||
| |_| FLOOR MID SECTION RIGHT SIDE | ||||||
| |_| FLOOR REAR LEFT SIDE | ||||||
| |_| OTHER: ___________________ | |_| FLOOR REAR RIGHT SIDE |
2. DESCRIPTION OF DAMAGED AREA AND REPAIR PROCESS
3. EQUIPMENT USED IN THE REPAIR & SETTINGS
WELDING PROCESS
CURRENT TYPE (DC REVERSE POLARITY OR DC STRAIGHT POLARITY)
TYPE/MODEL WELDING MACHINE
ELECTRODE (i.e. E7018) WELD WIRE LOT# FILLER METAL CLASSIFICATION (i.e. ER70S-6) DIAMETER
SHIELDING GAS COMPOSITION FLOW RATE(CU.FT./HR)
POSITION |_|FLAT |_|HORIZONTAL |_|OVERHEAD |_|VERTICAL UP |_|VERTICAL DOWN
WELD JOINT TYPE |_|GROOVE (BUTT) |_|LAP |_|CORNER |_|TEE |_|OTHER
WELDING PARAMETERS AMPS(A) WIRE FEED SPEED(IN/MIN) VOLTAGE(V)
NUMBER OF PASSES PER SIDE SIDE ONE SIDE TWO
INTERPASS CLEANING |_| WIRE BRUSH |_| GRINDING |_| NONE |_|
4. MATERIAL USED IN THE REPAIR
PARTS AND OTHER MATERIAL:
COMMENTS:
STEEL DATA LOT#
JON
SubJON
PCC
DATE ENTERED INTO DMIS
This document must be submitted electronically to host@gdls.com when completed
Extent of Flat Bottom (FBH) Stryker hull field repair allowed for FSRR covered repair NOTE: when FSRR authorized hull repair was completed by a field welder and FSRR submitted to HOST E-mail address (see page 1), submission of Preliminary Hull Damage Assessment is not required
Extent of Double-V (DVH) Stryker hull field repair allowed for FSRR covered repair NOTE: when FSRR authorized hull repair was completed by a field welder and FSRR submitted to HOST E-mail address (see page 1), submission of Preliminary Hull Damage Assessment is not required
FSRR authorized repair – DVH hull
Following hull damage can be repaired by filed welder and FSRR completed:
Small cracks in welds and HAZ. HAZ is defined as of maximum 15.8 mm from the toe of the weld
· Gouges in weld covers only can be repaired. Gouge is identified as a blunt grove or surface cavity resulting from material excavation. Weld covers gouges which are allowed to be repaired under FSRR authority shall be:
· 1/8 inches (3 mm ) deep or deeper. Gouges with depth less than 1/8 inches (3 mm) need not be repaired.
· Gouge is confined within weld cover and does not extend in hull plates
· There is no crack associated with a gouge
· Gouge area is less than 8 sq inches (5000 sq mm)
· Dents in weld covers, rear floor, LH and RH sponson, drivers floor and engine floor need not be repaired. Dent is identified as a localized deformation of material which violates design profile.
· Individual tapping pads damaged beyond use can be removed and replaced
· Individual footman loops regardless of length can be removed and replaced
· #1 axle front and rear and #2 axle front A-frame mounts welded to engine floor only can be removed and replaced, fixture M-6590 required
LS1080654
LS1081396
LS1081374
Fixture M-6590
· #1 and #2 front differential mounts welded to RH vertical leg of front main tunnel only can be removed and replaced, fixture M-M-6535 will be required
LS1082425
LS1082694
LS1082425
Fixture M-6535
DISTRIBUTION STATEMENT D: Distribution authorized to the Department of Defense and DoD contractors only, per the STRYKER Security Classification Guide and Program Protection Plan. Date of determination is 27 March 2003. Other requests for this document shall be referred to Project Manager Brigade Combat Team, ATTN: SFAE-GCS-BCT, DSN 786-2000 or Commercial 586-753-2000 image3.jpeg image4.jpeg image5.jpeg image6.jpeg image7.png image8.png image9.png image10.png image11.png image12.png image13.png image14.png image1.jpeg image2.jpeg image15.png