Addendum 3 - S-001-GENERAL NOTES.pdf
PDF 155 KB Posted
- Attached to
- Construct Corrosion Control Facility Federal contract opportunity
- Solicitation number
- W50S78-24-B-0002
- Issued by
- Department of the Army National Guard
About this file
This document is an Addendum to the General Notes for the design of a new 12,200 square foot Corrosion Control Facility for the Texas Air National Guard at Joint Base San Antonio - Kelly Field Annex. It provides detailed design criteria, including governing building code, design loads, seismic design data, and material design values for the concrete, steel, and other structural components. The document also includes construction notes regarding coordination with existing utilities and structures, temporary shoring requirements, and submittal procedures.
The related federal contract opportunity is for the construction of this new Corrosion Control Facility. The solicitation is set aside 100% for small businesses under NAICS code 236220, with a project value between $10-25 million. In addition to a base bid, the solicitation includes 4 options and several brand name items required for compatibility with existing systems. A site visit and pre-bid conference are scheduled, and all questions/RFIs must be submitted prior to bid opening. The contract duration is 540 calendar days after notice to proceed.
View the file
Other files for this federal contract opportunity
Show all 49
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESIGN CRITERIA:
GOVERNING BUILDING CODE: IBC 2021
BUILDING RISK CATEGORY: III
DESIGN LOADS:
DEAD LOADS:
ROOF SYSTEM ..................................................... 20 PSF COLLATERAL FRAMING................................................................ ACTUAL WEIGHT OF MATERIALS, UNLESS NOTED OTHERWISE
INSULATION........................................................... 1 PSF
CEILING COLLATERAL........................................... 3 PSF
MISC/MECH COLLATERAL..................................... 5 PSF
LIVE LOADS:
ROOF (NON-REDUCIBLE)....................................... 20 PSF
SNOW LOAD: (ASCE 7-16)
BASIC GROUND SNOW LOAD, (Pg)...................... 5 PSF
TERRAIN CATEGORY............................................. C
ROOF EXPOSURE................................................... PARTIAL
EXPOSURE FACTOR, (Ce)...................................... 1.0 THERMAL FACTOR, (Ct)......................................... 1.0 SLOPE FACTOR, (Cs).............................................. 1.0 IMPORTANCE FACTOR, (Is).................................... 1.1 SLOPED ROOF SNOW, (Ps)................................... 5 PSF
WIND LOAD: (ASCE 7-16)
BUILDING DESIGN:
BASIC WIND SPEED................................................. 115 MPH
EXPOSURE CATEGORY........................................... C
IMPORTANCE FACTOR, (Iw).................................... 1.0 TOPOGRAPHIC FACTOR, (Kzt)............................... 1.0
BUILDING ENCLOSURE CATEGORY...................... PARTIALLY ENCLOSED BUILDING
SEISMIC DESIGN DATA: (ASCE 7-16)
SHORT PERIOD ACCELERATION, SS ................... 0.05 g LONG PERIOD ACCELERATION, S1...................... 0.02 g
SOIL SITE CLASS ................................................... D
SITE COEFFICIENT, Fa ........................................... 1.6 SITE COEFFICIENT, Fv .......................................... 2.4 DESIGN SPECTRAL ACCELERATION, S DS .......... 0.054 g DESIGN SPECTRAL ACCELERATION, S D1 .......... 0.032 g
SEISMIC DESIGN CATEGORY .............................. A
ANALYSIS METHOD................................................ EQUIVALENT LATERAL FORCE
SEISMIC FORCE RESISTING SYSTEM................ STEEL SYSTEMS NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE
DESIGN BASE SHEAR........................................... AS REQUIRED BY MBM
TEMPERATURE:
STRUCTURE SHALL BE ANALYZED FOR T = +110,-0 °F (±55°F TOTAL ΔT )
ACI AMERICAN CONCRETE INSTITUTE
ADD'L ADDITIONAL
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ANCH ANCHOR
AR ANCHOR ROD
ARCH ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASD ALLOWABLE STRESS DESIGN
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
AT/FP ANTI-TERRORISM FORCE PROTECTION
AWS AMERICAN WELDING SOCIETY
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BASE PLATE
BR BRACING
BRG BEARING
BTWN BETWEEN
CJ CONSTRUCTION JOINT
CL, CENTER LINE
CL COLLATERAL LOAD
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONNX CONNECTION
CONT CONTINUOUS
COORD COORDINATE
CR CENTER OF RADIUS
DBA DEFORMED BAR ANCHOR
DBE DECK BEARING ELEVATION
DEG DEGREE
db DIAMETER BAR
DIA DIAMETER
DL DEAD LOAD
DN DOWN
DWLS DOWELS
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATION
EQ EQUAL
EQUIV EQUIVALENT
EW EACH WAY
EXP EXPANSION
ºF/C DEGREES FAHRENHEIT/CELSIUS
FF FINISH FLOOR
FFE FINISHED FLOOR ELEVATION
FIN FINISH
FLR FLOOR
FLG FLANGE
FND FOUNDATION
FT FOOT/FEET
FTG FOOTING
FS FAR SIDE
GA GAGE
GALV GALVANIZED
GB GRADE BEAM
HORIZ HORIZONTAL
IBC INTERNATIONAL BUILDING CODE
IN INCH/INCHES
JB JOIST BEARING
JST JOIST
JT JOINT
LBS POUNDS
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LRFD LOAD AND RESISTANCE FACTOR DESIGN
LSH LONG SIDE HORIZONTAL
LSSH LONG SLOTTED HOLES
MBM METAL BUILDING MANUFACTURER
MFR MANUFACTURER
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFG MANUFACTURER
MIN MINIMUM
MPH MILES PER HOUR
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OH OPPOSITE HAND
OPNG OPENING
OVS OVERSIZED
PERIM PERIMETER
PL PLATE
± PLUS/MINUS
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
REF REFER
REINF REINFORCE/REINFORCING
ABBREVIATIONS REQ'D REQUIRED
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SF SQUARE FEET
SIM SIMILAR
SJ SAWCUT JOINT
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SSLT SHORT SLOTTED HOLES
SSMA STEEL STUD MANUFACTURERS
ASSOCIATION
STD STANDARD
STIFF STIFFENER
TO TOP OF
TOF TOP OF FOUNDATION/FOOTING
TOS TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
W/O WITHOUT
WL WIND LOAD
WP WORKING POINT
WWF WELDED WIRE FABRIC
WWR WELDED WIRE REINFORCEMENT
MATERIAL DESIGN VALUES:
CONCRETE (MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS,
NORMAL WEIGHT, UNLESS NOTED OTHERWISE)
SLABS ON GRADE, STRUCTURAL SLABS,
AND FOUNDATIONS ................................................... 4,000 PSI
CONCRETE REINFORCEMENT(MINIMUM YIELD STRENGTH)
ALL DEFORMED BARS, UNLESS NOTED OTHERWISE.
(ASTM A615, GRADE 60)..................................... fy = 60,000 PSI WELDED WIRE FABRIC (ASTM A185).......................... fy = 60,000 PSI SMOOTH BARS (ASTM A82).......................................... fy = 70,000 PSI DEFORMED BAR ANCHORS (ASTM A706)................... fy = 60,000 PSI
STRUCTURAL STEEL (MINIMUM YIELD STRENGTH)
WIDE FLANGES (ASTM A992 OR A572, GR. 50)......... Fy = 50,000 PSI HSS ROUND (ASTM A500, GRADE C).......................... Fy = 46,000 PSI
HSS SQUARE (ASTM A500, GRADE C)........................ Fy = 50,000 PSI PIPES (ASTM A53, GRADE B)....................................... F y = 35,000 PSI
ALL OTHER SHAPES AND PLATES
UNLESS NOTED OTHERWISE (ASTM A36)......... Fy = 36,000 PSI
ANCHOR RODS
(ASTM F 1554, WELDABLE GRADE 55)................ Fy = 55,000 PSI
COLD FORMED STRUCTURAL SHAPES............................. Fy = 33,000 PSI (MIN)
MISCELLANEOUS NOTES:
1.
2.
3.
4.
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION
WITH PROJECT SPECIFICATIONS AND ALL OTHER DISCIPLINE
CONSTRUCTION DOCUMENTS.
IF THERE IS CONFLICTING INFORMATION, THE MORE
STRINGENT SHALL BE ASSUMED. IF THERE IS NOT A CLEAR
INTENT, CONTACT THE ARCHITECT/ENGINEER OF RECORD.
GENERAL NOTES AND TYPICAL DETAILS APPLY TO THE
ENTIRE PROJECT AND CONVEY ENGINEERING INTENT.
SPECIFIC DETAILS ARE NOT DRAWN FOR EVERY CONDITION
OF CONSTRUCTION OR ASSEMBLY. MANY CONDITIONS
SIMILAR TO THOSE DEPICTED EXIST AND THOSE SIMILAR
CONDITIONS ARE INCLUDED IN THE CONTRACT SCOPE OF
WORK. THE CONTRACTOR SHALL INCLUDE COST OF THE
WORK FOR THESE SIMILAR CONDITIONS. FUTURE
CLARIFICATION OF DETAILS SHALL NOT BE THE BASIS OF
ADDITIONAL COMPENSATION FOR THE CONTRACTOR.
REFERENCE DATUM ELEVATION 100'-0" IS EQUAL TO THE
ACTUAL FINISH FLOOR ELEVATION PROVIDED BY CIVIL.
REFERENCED ELEVATIONS ARE BASED ON THIS DATUM
ELEVATION.
SOILS/FOUNDATION NOTES:
1.
2.
3.
4.
5.
6.
FOUNDATION RECOMMENDATIONS ARE BASED ON THE
GEOTECHNICAL REPORT PREPARED BY ROCK ENGINEERING
AND TESTING LABORATORY, INC. DATED MAY 28, 2019 FOR
PROPOSED AIRCRAFT CORROSION CONTROL FACILITY, KELLY
FIELD ANNEX, SAN ANTONIO, TEXAS, PROJECT NO.:219147.
ALLOWABLE UNDERREAMED DRILLED PIER FOUNDATION
CAPACITY (WITH MIN. 17 FT BELOW EXISTING GRADE):
END BEARING ………………………………..12,000 PSF
FLOOR SLABS SHALL BE CONSTRUCTED ON 12" CARTON
VOID FORMS. THE BUILDING SLAB SHALL BE PLACED OVER A
VAPOR RETARDER AS SPECIFIED IN THE SPECIFICATIONS.
AFTER EXCAVATING, FOOTINGS SHOULD BE INSPECTED AND
CONCRETE PLACED AS QUICKLY AS POSSIBLE TO AVOID
EXPOSURE TO WETTING AND DRYING.
WATER SHOULD NOT BE ALLOWED TO COLLECT IN THE
EXCAVATIONS OR NEAR THE FOUNDATIONS AND FLOOR SLAB
AREAS OF THE BUILDINGS DURING CONSTRUCTION.
FOUNDATION DESIGN IS BASED ON PRELIMINARY METAL
BUILDING REACTIONS. THE GC SHALL SUBMIT FINAL METAL
BUILDING REACTIONS PRIOR TO OR AT THE SAME TIME OF
SUBMITTING THE REINFORCING SUBMITTAL FOR
FOUNDATIONS. THE FOUNDATIONS WILL BE RE-EVALUATED
USING THE FINAL REACTIONS.
CONSTRUCTION NOTES:
1.
2.
3.
4.
5.
6.
7.
ALL DIMENSIONS AND ELEVATIONS RELATED TO EXISTING
STRUCTURES MUST BE VERIFIED IN THE FIELD AS REQUIRED
FOR NEW CONSTRUCTION. SIGNIFICANT DISCREPANCIES
SHALL BE REPORTED TO THE ARCHITECT/ENGINEER OF
RECORD.
THE SPECIFIED DIMENSIONS ON THE DRAWINGS SHALL
GOVERN, SCALING DRAWINGS IS AT THE RISK OF THE
CONTRACTOR.
ALL INTERFERING PIPES, UTILITIES, AND FIXTURES WILL BE
RELOCATED BY CONTRACTOR AS REQUIRED.
THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL
SHORING, PROPS, AND GUYS REQUIRED FOR THE
TEMPORARY SUPPORT OF THE EXISTING STRUCTURE AND
REMOVE SAME AFTER COMPLETION.
THE CONTRACTOR IS HELD RESPONSIBLE FOR PROTECTION
OF PERSONNEL AND EQUIPMENT DURING THE COURSE OF
OPERATIONS ACCORDING TO CURRENT SAFETY
REGULATIONS.
THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER COPIES
OF SHOP DRAWINGS OF ALL NEW WORK TO THE ENGINEER
OF RECORD FOR REVIEW.
THE CONTRACTOR SHALL REPAIR ALL EXISTING WORK WHICH
HAS BEEN DAMAGED BY HIS CONSTRUCTION OPERATIONS
AND REMOVE ALL DEBRIS FROM THE SITE AFTER
COMPLETION OF THE PROJECT.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
20190320
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
TX
AN
G Pr oj ec t N um be r:
KE
LL
JB
SA
Ke lly A nn ex , T X
Te xa s Ai r N at io na l G ua rd 9t h
FW
Co rro sio n Co nt ro l F ac ilit y
NDM
A
B C D
A B C D
E F G H
E F G
H I
I
C :\U sers\nolm stead\D ocum ents\90320_Stru_nolm steadFK74B.rvt 09/09/24 16:52:18
2 AUGUST 2024
S-001
GENERAL NOTES
BJW
CGH
CGH
1 ADDENDUM 03 09/09/2024
File details come from the government source that posted it. Updated .