Attachment 1.a. - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_DRAWINGS (1-74) 2024.08.02.pdf

PDF 23 MB Posted

Attached to
Construct Corrosion Control Facility Federal contract opportunity
Solicitation number
W50S78-24-B-0002
Issued by
Department of the Army National Guard

About this file

This document is the Attachment 1.a. - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_DRAWINGS (1-74) for the federal contract opportunity to Construct Corrosion Control Facility with Solicitation Number W50S78-24-B-0002.

The Texas Air National Guard intends to issue an Invitation for Bids to award a single firm fixed-price contract for the construction of a new 12,200 square foot Corrosion Control Facility at Joint Base San Antonio - Kelly Field Annex. The facility will include an environmentally controlled aircraft wash area, hangar space for corrosion treatment and repair, paint preparation and drying areas, abrasive blasting rooms, paint mixing and application booths, tool storage, lockers, and administrative areas. The project will also include 1,500 square yards of airfield pavements. The contract duration is 540 calendar days after notice to proceed. This project is 100% set aside for Small Businesses under NAICS code 236220 with a size standard of $45,000,000. The magnitude of construction is between $10,000,000 and $25,000,000. The solicitation includes a Base Bid and four Options: Translucent Fiberglass Panel, Screen Wall, Alternate Roof (SSMR), and Epoxy Flooring. The solicitation also includes four Brand Name items for compatibility with existing installation systems.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Corrosion Control Facility, newest first.
File Type Posted
Corrosion Control Facility - Abstract of Bidders - REVISED - 20240924.pdf PDF
Corrosion Control Facility - Abstract of Bidders 20240918.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 05 - 20240913.pdf PDF
Addendum 3 - S-001-GENERAL NOTES.pdf PDF
Addendum 3 - SB507-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB506-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB508-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB102-SLAB PLAN.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 04 - 20240910.pdf PDF
Addendum 3 - G-203-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-500-DETAILS.pdf PDF
Addendum 3 - A-103-ROOF PLAN.pdf PDF
Addendum 3 - A-101-FLOOR PLAN.pdf PDF
Addendum 03 Cover Page.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 230 (20240910).pdf PDF
Attachment 12 - JBSA-Soil Management Plan - Signed Jan 22.pdf PDF
Addendum 3 - G-201-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-501-DETAILS.pdf PDF
Attachment 13 - Kelly Annex CORROSION CONTROL-TOPO.pdf PDF
Addendum 3 - G-002-SHEET INDEX.pdf PDF
Addendum 3 - EG502-GROUNDING AND LIGHTNING PROTECTION DETAILS.pdf PDF
Addendum 3 - A-104-HANGAR BAY FLOOR PAINT STRIPING PLAN.pdf PDF
Addendum 3 - 09 06 00 - SCHEDULES OF FINISHES.pdf PDF
Addendum 3 - 08 34 16.10 - HORIZONTAL ROLLING STEEL DOORS.pdf PDF
Addendum 3 - G-202-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-201-BUILDING ELEVATIONS.pdf PDF
Addendum 3 - 01 14 00 - WORK RESTRICTIONS.pdf PDF
ADDENDUM 2- SPECIFICATIONS -08 34 16.10 -- DRAWING - A-603.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 03 - 20240905.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 11 (20240829).pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 02 - 20240829.pdf PDF
Attachment 11 - Geotechical report - TX ANG CC Facility.pdf PDF
ADDENDUM 1 - SPECIFICATIONS VOL 1 - SECTION 08 71 00 DOOR HARDWARE.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 01 - 20240823.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 5 (20240823).pdf PDF
Pre-Proposal Site Visit Slides_Corrosion Control 20 Aug 24.pptx PPTX presentation
Pre_Bid_Site Visit_Corrosion Control_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 1 - TX-ANG_CORROSION CONTRAOL HANGAR_TYPE B3_DRAWINGS.pdf PDF
Attachment 10 - Monaco Redacted.pdf PDF
Attachment 1.b. - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_DRAWINGS (75-136) 2024.08.02.pdf PDF
Attachment 2 - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_VOL 1 SPECIFICATIONS 2024.08.02.pdf PDF
Attachment 6 - Access and staging site plan.pdf PDF
W50S7824B0002 Corrosion Control Facility -Solicitation - 20240809.pdf PDF
Attachment 3 - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_VOL 2 SPECIFICATIONS 2024.08.02.pdf PDF
Attachment 4 - STRUCTURAL INTERIOR DESIGN.pdf PDF
Attachment 9 - Falcon Redacted.pdf PDF
Attachment 5 - Industrial Security SOW.pdf PDF
Attachment 7 - DDC Redacted.pdf PDF
Attachment 8 - Trane Redacted.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

ELEC ELEC

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS

TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

S S S SS S S S S

0 15' 30' 60' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

ACCESS AND STAGING PLAN

C-101

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

S SS S S S S S S S

0 10' 20' 40' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

STORM WATER POLLUTION

PREVENTION PLAN

C-201

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

STORM WATER POLLUTION

PREVENTION DETAILS

C-202

GAS GAS GAS GAS GAS GAS GAS GAS GAS

tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL T

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

0 10' 20' 40' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

REMOVAL PLAN

C-301

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

SS S S S S S S S

TOW

ONLY

0 10' 20' 40' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

PROPOSED PLAN

C-401

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

TYPICAL SECTION AND

PAVEMENT DETAILS

C-402

0 5' 10' 20' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

JOINTING PLAN

C-403

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

PAVEMENT JOINTING DETAILS

C-404

0 5' 10' 20' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

STAKING PLAN

C-405

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

S SS S S S S S S S

0 10' 20' 40' N

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

GRADING PLAN

C-501

GAS GAS GAS GAS GAS GAS GAS

tr

Sv c

W tr

Sv c

W tr

Sv c

W tr

Sv c

Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-SS Ex-S

TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

TEL

SS S S S S

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

0 15' 30' 60' N

UTILITY PLAN

C-601

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

Structure Northing Easting Type Rim El. Invert El. Pipe Pay Length Size Type Slope %

S1 13688372.2811 2096957.9021 4' Manhole 677.54 666.53

59.9 15.0 RCP 1.00

S2 13688429.6115 2096929.7904 4' Manhole 678.10 665.90

51.0 15.0 RCP 1.00

S3 13688484.6115 2096929.7904 4' Manhole 677.80 665.35

52.1 15.0 RCP 1.00

S4 13688540.6906 2096929.7904 4' Manhole 679.04 664.78

72.4 15.0 RCP 1.00

S5 13688619.1444 2096929.7904 10' Doghouse Manhole 678.15 S 664.00 E/W 660.00* Existing 84.0 RCP

S6 13688540.6906 2097034.0948 4' Manhole 678.00 665.82

100.3 15.0 RCP 1.00

S4 13688540.6906 2096929.7904 4' Manhole 679.04 E 664.78

DRAINAGE SCHEDULE AND

DETAILS

C-602

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

Structure Structure Diameter Frame Height Grate Diameter Frame Type Cover/Grate

Number Type D (in.) (in.) (in.) (Neenah/East Jordan/US Foundry) or Approved Equal

(Neenah/East Jordan/US Foundry) or Approved Equal

S1 Manhole 48 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

S2 Manhole 48 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

S3 Manhole 48 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

S4 Manhole 48 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

S5 Manhole (Doghouse) 120 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

S6 Manhole 48 4.5 32 R-1930-30/1495/111 Ring R-2930-30/V3419/5624

DRAINAGE DETAILS

C-603

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

SANITARY DETAILS

C-604

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

Structure Northing Easting Type Rim El. Invert El. Pay Length Size Slope

T1 Meet Building Trench Drain Outlet --- 676.12

43.4 10.0 0.24

T2 13688405.0624 2096914.9495 Manhole 678.74 676.02

8.6 10.0 0.24

T3 13688427.9902 2096914.9495 Oil Water Separator 678.47 676.00 675.90

5.0 10.0 0.24 T4 13688447.3235 2096914.9495 Manhole 678.28 675.89

106.9 10.0 0.24 T5 13688554.2361 2096914.9495 Manhole 679.44 675.64

219.9 10.0 0.24 T6 Connection to Existing Manhole --- 675.11

--- Connection to Building --- 676.11

43.5 4.0 0.50

T4 13688447.3235 2096914.9495 Manhole 678.28 675.89

SANITARY SCHEDULE AND

DETAILS

C-605

ELEVATION

END VIEW

PLAN

3. 15000 VOLT SPARK TEST PROVIDED AT FACTORY

1. TANK IS NOT APPROVED FOR THE STORAGE OF HEATED PRODUCTS

2. ALL VENT PIPING BY INSTALLER

NOTES

UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES

TOLERANCES ARE + OR - 1"

1. 150# R.F.S.O. FLANGE WITH 2" FNPT FOR VENT

3. VELOCITY HEAD DIFFUSION BAFFLE

4. WEAR PLATE

5. SEDIMENT CHAMBER

6. UNDERFLOW BAFFLE

7. SLUDGE BAFFLE

8. STRIKER PLATES

10. OIL/WATER SEPARATOR CHAMBER

12. STEEL OUTLET DOWNCOMER

13. 24"Ø MANWAY WITH GASKETS.

14. 4"Ø FNPT FOR OIL PUMP-OUT WITH INTERNAL PVC PIPE INSTALLED

15. 2"Ø FNPT FOR LEVEL SENSOR.

16. LIFTING LUG

17. 2"Ø FNPT FOR VENT

2. 4"Ø FNPT FOR GAUGE WITH PLUG

9. PARALLEL CORRUGATED PLATE COALESCER.

11. 6" THICK COALESCER MATERIAL INSTALLED WITH PULL

ROD SHIPPED LOOSE

EQUIPMENT

18. 2"Ø FNPT FOR LEAK SENSOR WITH RISER PIPE

ANCILLARY EQUIPMENT

(4) 24" MANWAY GASKETS

(4) SETS OF NUTS/BOLTS/WASHERS FOR 24" MANWAY

6,000 GALLON OIL WATER SEPARATOR

4. SEPARATOR SHALL BE SUPPLIED WITH AN AUDIBLE AND VISUAL

ALARM SYSTEM THAT INDICATES HI OIL LEVEL (VISUAL ONLY) AND

HI-HI OIL LEVEL (AUDIBLE AND VISUAL) OF OIL STORAGE IN THE

OIL/WATER SEPARATOR. AN AUDIBLE AND VISUAL LEAK DETECTION

ALARM SYSTEM THAT INDICATES HYDROCARBON AND/OR WATER IN

THE INTERSTICE WILL ALSO BE PROVIDED. A SILENCE CONTROL

SHALL BE PROVIDED FOR THE AUDIBLE ALARMS. LEVEL SENSOR(S)

TO BE INTRINSICALLY SAFE. LEVEL SENSOR FLOATS TO BE MADE OF

STAINLESS STEEL. THE CONTROL PANEL SHALL CONTAIN BOTH LEVEL

SENSOR AND LEAK DETECTION CONTROL.

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

SANITARY OIL-WATER

SEPARATOR DETAILS

C-606

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

WATER DETAILS

C-607

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

C-608

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

20190320

NDM

Offices Nationwide www.hanson-inc.com

Hanson Professional Services Inc.

1525 S. 6th Street Springfield, IL 62703 phone: 217-788-2450 fax: 217-788-2503

RMH

LDH

LDH

2 AUGUST 2024

C-609

TRANSITION SCHEDULE

FLOORING MATERIAL TRANSITION TYPE FINISH / COLOR NOTES

EP TO VCT

EF TO VCT METAL TRANSITION FOR TILE ANODIZED ALUMINUM INSTALL LEG UNDER TILE

CPT TO VCT METAL TRANSITION ANODIZED ALUMINUM INSTALL LEG UNDER CARPET

CONC TO VCT RESILIENT TRANSITION 32 PEBBLE

PRC TO EP INSTALL LEG UNDER TILEMETAL TRANSITION FOR TILE ANODIZED ALUMINUM

INSTALL LEG UNDER TILEMETAL TRANSITION ANODIZED ALUMINUM

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

20190320

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

TX

AN

G Pr oje ct

Nu mb er:

K

EL

L 1

JB

SA

Ke lly

A nn ex , T

X

Te xa s A ir

Na tio na l G ua rd

9t h

FW

Co rro sio n C on tro l F ac ilit y

NDM

A

B C D

A B C D

E F G H

E F G

H I

I

C :\U sers\kxd\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_kdespainN

TT3U

.rvt

8/1/2024 3:35:02 PM

2 AUGUST 2024

A-602

ROOM FINISH SCHEDULE

BKG

KAH

JCL

ROOM FINISH SCHEDULE

ROOM NUMBER. ROOM NAME Area

FLOOR

FINISH BASE FINISH

WALL FINISHES

CEILING FINISH

CEILING

HEIGHT NOTESNORTH SOUTH EAST WEST

101 VEST 91.73 SF EF1 RB1 PT1 PT1/GL PT1 PT1/GL ACP1

102 CORR 130.05 SF VCT1 RB1 -- PT1 PT1 PT1 ACP1

103 MEDIA 218.82 SF CPT1 RB1 PT1 PT1/GL PT1 PT1/GL ACP1

104 OFFICE 74.52 SF CPT1 RB1 WC1 PT1/GL PT1 PT1 ACP1

105 ADMIN 136.4 SF CPT1 RB1 PT1/WC1 PT1 PT1 -- ACP1

106 JAN. 41.81 SF CONC1 RB1 FRP1 / PT1 FRP1 / PT1 FRP1 / PT1 FRP1 / PT1 GYP BD / PT3 3, 6, 7

107 CORR 238.94 SF VCT1 RB1 PT1 PT1 PT1 PT1 ACP1

108 BREAK 40.17 SF VCT1 RB1 -- PT1 PT1 PT1 EXP, PT3

109 BREAK 42.09 SF VCT1 RB1 PT1 PT1 PT1 PT1 GYP BD / PT3 12

110 COMM 97.72 SF SDT1 RB1 PT1 PT1 PT1 PT1 EXP, PT3 1

111 CORR 130.3 SF VCT1 RB1 PT1 PT1 PT1 PT1 EXP, PT3 12

112 CLEAN RR M 165.21 SF PRC1 PRB1 PT1 PRC2 PRC2 PRC2 GYP BD / PT3 2, 4, 6

113 DIRTY RR M 236.34 SF PRC1 PRB1 PT1 PRC2 PRC2 PRC2 GYP BD / PT3 2, 4, 6

114 DIRTY VEST 54.56 SF EF1 PRCB1 PT1 PT1 PT1 PT1 GYP BD / PT3

115 CLEAN RR W 165.98 SF PRC1 PRCB1 PRC2 PT1 PRC2 PRC2 GYP BD / PT3 2, 4, 6

116 DIRTY RR W 207.24 SF PRC1 PRCB1 PRC2 PT1 PRC2 PRC2 GYP BD / PT3 2, 4, 6

117 CLEAN VEST 37.71 SF EF1 PRCB1 PT1 PT1 PT1 PT1 GYP BD / PT3

118 MAINT. BAY 6486.39 SF EP1 EP1 PT1 PT1 PT1 PT1 EXP, PT3 3, 8

119 PREP 851.94 SF CONC1 RB1 PT1 PT1 PT1 PT1 GYP BD / PT3

120 PLASTICS 869.25 SF CONC1 RB1 PT1 PT1 PT1 PT1 GYP BD / PT3 1

121 MECH 346.62 SF CONC1 - PT1 PT1 PT1 PT1 EXP, PT3 1

122 FIRE PROT 259.24 SF CONC1 - PT1 PT1 PT1 PT1 EXP, PT3 1

123 ELEC 154.82 SF CONC1 - PT1 PT1 PT1 PT1 EXP, PT3 1

FINISH SCHEDULE NOTES

1. REFER TO SPECIFICATION SECTION 090600

“SCHEDULES FOR FINISHES” FOR FINISHES AND

MATERIALS.

2. REFER TO INTERIOR ELEVATIONS ON SHEET A-403

FOR WALL TILE PATTERNS AND EXTENTS.

3. PROVIDE SMOOTH TRANSITION BETWEEN

DIFFERENT FLOORING MATERIALS. REFER TO

TRANSITION LEGEND.

4. ALL TILED FLOORING INSTALLATIONS SHALL BEGIN

WITH A FULL TILE CENTERED IN ROOM, UNLESS

NOTED OTHERWISE. IF CENTERING FULL TILE

RESULTS IN LESS THAN HALF THE WIDTH OF THE

TILE AT THE PERIMETER OF THE ROOM, ADJUST

THE START POINT BY HALF TILE WIDTH IN BOTH

DIRECTIONS.

5. ALL EXPOSED CEILINGS AND STRUCTURES TO BE

PAINTED (PT3).

6. ALL WALLS WITH AREAS OF EXPOSED GWB IN WET

AREAS (RESTROOMS AND JANITOR CLOSET) ARE TO

BE PAINTED WITH EPOXY PAINT.

7. PROVIDE FRP TO 96" AFF WITH EPOXY PAINT

ABOVE.

8. WALLS WITH AREAS OF EXPOSED GWB IN

MAINTENANCE BAY ARE TO BE PAINTED WITH HIGH

PERFORMANCE PAINT.

9. ALL DOOR FRAMES ARE TO BE PAINTED (PT2) ,U.N.O

10. ALL WINDOWS SHALL RECEIVE ROLLER SHADES

(RS1), U.N.O.

11. PROVIDE STAINLESS STEEL CORNER GUARDS FOR

OUTSIDE CORNERS OF GYPSUM BOARD WALLS.

12. PAINT ACOUSTIC CEILING GRID ON ALL EXPOSED

SIDES.

13. EP1 3-PART EXPOXY FLOORS IN MAINTENANCE BAY

ARE BASE BID. EP2 5-PART EPOXY FLOORS IN

MAINTENANCE BAY IS A BID OPTION.

14. LISTED BASIS-OF-DESIGN PRODUCTS ARE

INCLUDED TO ILLUSTRATE MINIMUM QUALITY AND

PERFORMANCE REQUIREMENTS ONLY. ANY

PRODUCT MAY BE USED THAT INCLUDES THE SAME

SALIENT CHARACTERISTICS AS THOSE INDICATED.

ABBREVIATION LEGEND

ACP ACOUSTICAL CEILING PANEL

CONC CONCRETE

CPT CARPET TILE

EF ENTRANCE FLOORING

EP EPOXY FLOORING

ESD ELECTROSTATIC DISSIPATIVE

EXP EXPOSED TO STRUCTURE

FRP FIBER-REINFORCED PANEL

GL GLASS

GR GROUT

GYP BD GYPSUM BOARD

PLAM PLASTIC LAMINATE

PT PAINT

PRC PORCELAIN TILE

PRCB PORCELAIN TILE BASE

RB RUBBER BASE

RS ROLLER SHADES

SDT STATIC DISSIPATIVE FLOORING

SSM SOLID SURFACE MATERIAL

VCT VINYL COMPOSITION TILE

ACP1 CPT1 EF1

ESD1 GR1 PLAM1 PRC1 PRC2

PT1

PT2 PT3 RB1 RS1 SSM1 TRANSITION - RESILIENT VCT1

DIGITAL FINISH EXAMPLES

FIRE PROT

MECH

ELEC

COMM

ADMIN

MEDIA

BREAK

CLEAN RR M

DIRTY RR M

CLEAN RR W

115 DIRTY RR W

CORR

MAINT. BAY

118PREP

JAN.

VEST

CLEAN VEST

DIRTY VEST

OFFICE

BREAK

PLASTICS

CORR

CORR

CH1

DK1

EQ1TA1

TA2TA2

EQ1

CH2CH2

CH2 CH2

TA2

TA2TA2

TA2

CH3

TA4

EQ2

EQ3

EQ3

SC1 SC1

CH2

TA2

CH2CH2

TA2 EQ1

TA2

EQ4

TA3 MB1

TA2

MB2

CM1

MW1

TA2

CH2

SC1

EQ7

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

20190320

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

TX

AN

G Pr oje ct

Nu mb er:

K

EL

L 1

JB

SA

Ke lly

A nn ex , T

X

Te xa s A ir

Na tio na l G ua rd

9t h

FW

Co rro sio n C on tro l F ac ilit y

NDM

A

B C D

A B C D

E F G H

E F G

H I

I

C :\U sers\kxd\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_kdespainN

TT3U

.rvt

8/1/2024 9:41:28 AM

2 AUGUST 2024

IF-101

FURNITURE PLAN

BKG

KAH

KAH

0 4' 8' 16'

1/8" = 1'-0"

N

SCALE 1/8" = 1'-0"

FURNITURE PLANA6

GENERAL NOTES

A. FURNITURE IS NOT IN CONTRACT AND IS SHOWN

FOR COORDINATION PURPOSES ONLY.

COORDINATION PURPOSES ONLY. CONTRACTOR IS

RESPONSIBLE FOR COORDINATION OF FINAL

LOCATIONS FOR POWER AND DATA FOR

FURNITURE, EQUIPMENT, AND FURNITURE

SYSTEMS WITH VENDOR.

B. GFGI: GOVERNMENT FURNISHED, GOVERNMENT

INSTALLED.

C. GFCI: GOVERNMENT FURNISHED, CONTRACTOR

INSTALLED.

D. REFER TO MECHANICAL, ELECTRICAL, AND

PLUMBING DRAWINGS FOR INFORMATION RELATED

TO POWER, DATA, TELECOM, SECURITY, WATER

LINES, ETC. THAT MUST BE COORDINATED WITH

FURNITURE & EQUIPMENT. ze

E. CONTRACTOR SHALL PROVIDE BLOCKING IN WALL

FOR ALL WALL MTD TVS, MONITORS, AND/OR

DISPLAYS.

F. CONTRACTOR SHALL PROVIDE BLOCKING IN WALL

FOR ALL MARKER BOARDS, TO BE MOUNTED AT 3’-0”

A.F.F. TO B.O. MARKER BOARD, U.N.O.

G. REFER TO SHEET A-401 FOR TOILET ACCESSORY

ROSTER WITH OTHER FIXTURES WHICH ARE IN

ADDITION TO THIS FURNITURE SCHEDULE.

FURNITURE SCHEDULE

Type Mark Description Comments

CH1 TASK CHAIR GFGI

CH2 TASK CHAIR GFGI

CH3 GUEST CHAIR GFGI

CM1 COFFEE MAKER GFCI

DK1 DESK, 72" x 72" GFGI

EQ1 MULTIFUNCTION DEVICE

COPY/PRINT

GFGI

EQ2 REFRIGERATOR GFCI

EQ3 STACKED WASHER/DRYER GFCI

EQ4 PLOTTER GFGI

EQ7 60" MONITOR GFCI

MB1 MARKER BOARD 84" X 48" GFCI

MB2 MARKER BOARD 48" X 48" GFCI

MW1 MICROWAVE GFGI

SC1 STORAGE CABINET GFGI

TA1 TABLE - 36"W x 30"D GFGI TA2 TABLE - 48"W x 30"D GFGI

TA3 WORK TABLE GFGI

TA4 TABLE - 48"W x 30"D GFGI

F

F F

F

F

FFFF

F

F

S C

AIM

AIM

AIM

AIM

AIM

F

FA

PXF

FA

CU

FIRE PROT

MECH

ELEC

COMM

ADMIN

MEDIA

BREAK

CLEAN RR M

DIRTY RR M

CLEAN RR W

115 DIRTY RR W

CORR

MAINT. BAY

118PREP

JAN.

VEST

CLEAN VEST

DIRTY VEST

OFFICE

BREAK

PLASTICS

CORR

CORR

1.01 TYPE 1

1.04 TYPE 1

1.06 TYPE 1

1.12 TYPE 1

1.11 TYPE 8 1.10 TYPE 8

1.09 TYPE 8

1.05 TYPE 3

1.02 TYPE 2

1.19 TYPE 1 1.18 TYPE 1

1.20 TYPE 4

1.22 TYPE 4

1.21 TYPE 2

1.13 TYPE 5

1.07 TYPE 6

1.03 TYPE 2

1.16 TYPE 10

1.17 TYPE 10

1.14 TYPE 8

1.23 TYPE 9

1.25 TYPE 9

1.26 TYPE 9

1.27 TYPE 9

1.28 TYPE 91.29 TYPE 9

1.30 TYPE 8

1.31 TYPE 8

1.32 TYPE 8

1.33 TYPE 8

1.35 TYPE 7

1.36 TYPE 7

1.37 TYPE 7

1.38 TYPE 7

1.39 TYPE 1

1.41 TYPE 3

EXTERIOR

GRADE SIGN

1.40 TYPE 3

1.42 TYPE 8

SIGNAGE PLAN LEGEND

TYPE

SIGN NUMBER SIGN TYPE

XXX

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

20190320

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

TX

AN

G Pr oje ct

Nu mb er:

K

EL

L 1

JB

SA

Ke lly

A nn ex , T

X

Te xa s A ir

Na tio na l G ua rd

9t h

FW

Co rro sio n C on tro l F ac ilit y

NDM

A

B C D

A B C D

E F G H

E F G

H I

I

C :\U sers\kxd\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_kdespainN

TT3U

.rvt

8/1/2024 9:41:29 AM

2 AUGUST 2024

IG-101

SIGNAGE PLAN

BKG

KAH

KAH

0 4' 8' 16'

1/8" = 1'-0"

NSCALE 1/8" = 1'-0"

SIGNAGE PLANA6

GENERAL NOTES

A. REFER TO SHEETS IG500 FOR SIGNAGE SCHEDULE,

ELEVATIONS, AND DETAILS.

B. CONTRACTOR IS IS TO VERIFY FINAL DIMENSIONS,

MATERIALS, FINISHES, AND ROOM NAMES /

NUMBERS WITH CONTRACTING OFFICER'S

TECHNICAL REPRESENTATIVE PRIOR TO

PROCUREMENT OF SIGNAGE.

C. FOR SIGNS MOUNTED TO GLASS, PROVIDE A

MATCHING OPAQUE FILM ON REVERSE SIDE OF

GLASS TO CONCEAL MOUNTING TAPE. COLOR TO

MATCH SIGN.

D. SIGNS MUST MEET ABA REQUIREMENTS.

E. SIGNS MUST COMPLY WITH UFC 3-120-01 DESIGN:

SIGN STANDARDS.

F. SIGNAGE PLAN AND SCHEDULES DO NOT INCLUDE

REGULATORY LABELING, ILLUMINATED EXIT SIGNS,

AND/OR HAZARD WARNINGS WHICH MAY BE

REQUIRED BY BUILDING AND/OR FIRE CODE.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING

ANY SUCH LABELING IN ACCORDANCE WITH

ADOPTED BUILDING CODES AND AS SPECIFIED BY

FIRE PROTECTION, ELECTRICAL, MECHANICAL,

AND/OR PLUMBING ENGINEER.

G. SIGNAGE PLAN AND SCHEDULES DO NOT INCLUDE

LABELING THAT MAY BE REQUIRED AT SOME DOOR

HARDWARE ELEMENTS, SUCH AS AUTOMATIC DOOR

OPERATORS OR EMERGENCY PANIC BARS. REFER

TO DOOR HARDWARE SPECIFICATIONS AND

ANSI/BHMA STANDARDS FOR REQUIRED LABELING

AT DOOR HARDWARE.

SIGNAGE SCHEDULE

SIGN NUMBER SIGN TYPE SIGN MESSAGE

1.01 TYPE 1 EXIT

1.02 TYPE 2 JANITOR

1.03 TYPE 2 MEDIA

1.04 TYPE 1 EXIT

1.05 TYPE 3 <VERIFY WITH OWNER>

1.06 TYPE 1 EXIT

1.07 TYPE 6 DANGER

1.09 TYPE 8 EXIT

1.10 TYPE 8 EXIT

1.11 TYPE 8 EXIT

1.12 TYPE 1 EXIT

1.13 TYPE 5 FIRE RISER

1.14 TYPE 8 FIRE EXTINGUISHER

1.16 TYPE 10 MEN'S LOCKER ROOM W

SHOWER

1.17 TYPE 10 WOMEN'S LOCKER ROOM

W SHOWER

1.18 TYPE 1 EXIT

1.19 TYPE 1 EXIT

1.20 TYPE 4 WOMEN'S RESTROOM

1.21 TYPE 2 COMM

1.22 TYPE 4 MEN'S RESTROOM

1.23 TYPE 9 NO SMOKING

1.24 TYPE 9 NO SMOKING

1.25 TYPE 9 NO SMOKING

1.26 TYPE 9 NO SMOKING

1.27 TYPE 9 NO SMOKING

1.28 TYPE 9 NO SMOKING

1.29 TYPE 9 NO SMOKING

1.30 TYPE 8 FIRE EXTINGUISHER

1.31 TYPE 8 FIRE EXTINGUISHER

1.32 TYPE 8 FIRE EXTINGUISHER

1.33 TYPE 8 FIRE EXTINGUISHER

1.35 TYPE 7 EMERGENCY EYEWASH

1.36 TYPE 7 EMERGENCY EYEWASH

1.37 TYPE 7 EMERGENCY EYEWASH

1.38 TYPE 7 EMERGENCY EYEWASH

1.39 TYPE 1 EXIT

1.40 TYPE 3 MECHANICAL

1.41 TYPE 3 ELECTRICAL

1.42 TYPE 8 FIRE EXTINGUISHER

9"

EXIT

REMOVABLE END CAPS, (SG3)

3/4" TACTILE TEXT, HELEVETICA

REGULAR 55 ROMAN MEDIUM,

CENTERED, (SG1)

1/4" 8 1/2" 1/4" 3"

BACKGROUND, (SG2)

BRAILLE, TYPE II,

WITHIN 3/8" FROM

TACTILE TEXT

3/ 4"

1" 3/

8"

9"

6"

3" XXX

1/4" 8 1/2" 1/4"

9"

REMOVABLE END

CAPS, (SG3)

1 1/2" TACTILE TEXT,

HELVETICA NEUE, 65

MEDIUM, FLUSH LEFT, (SG1)

BRAILLE, TYPE II

ROOM NAME 3/4" TACTILE TEXT,

HELVETICA NEUE, 55

ROMAN, FLUSH LEFT, (SG2)

BRAILLE, TYPE II

LOCATED 3/8" FROM

TACTILE TEST

BACKGROUND, (SG2)

BACKGROUND, (SG1)3/

8"

3/ 8"

9"

6"

3" XXX

1/4" 8 1/2" 1/4"

9"

REMOVABLE END

CAPS, (SG3)

1 1/2" TACTILE TEXT,

HELVETICA NEUE, 65 MEDIUM,

FLUSH LEFT (SG1)

BRAILLE, TYPE II,

LOCATED WITHIN 3/8"

OF TACTILE TEXT

ROOM NAME 3/4" PRINTED MESSAGE,

HELVETICA NEUE, 55 ROMAN,

FLUSH LEFT, (SG1)

PRINTED PAPER INSERT

WITH POLY CARBONATE

COVER

BACKGROUND, (SG2)

NOTE: EXTERIOR SIGNS

SHALL BE CONSTRUCTED

AND INSTALLED USING

EXTERIOR GRADE

MATERIALS.

9"

3" 8"

3" XXX

REMOVABLE END CAPS,

(SG3)

1 1/2" TACTILE TEXT,

HELVECTICA NEUE, 65

MEDIUM, FLUSH LEFT (SG1)

6" PICTOGRAPH, (SG2)

1" TACTILE TEXT, HELEVTICA

NEUE, 55 ROMAN MEDIUM,

CENTERED, (SG1)

1/4" 8 1/2" 1/4"

1'

2"

MEN

BACKGROUND, (SG2)

BACKGROUND, (SG2)

BRAILLE, TYPE II

BRAILLE, TYPE II

BACKGROUND, (SG1)

9"

3" 8"

3" XXX

REMOVABLE END CAPS,

(SG3)

1 1/2" TACTILE TEXT,

HELVECTICA NEUE, 55

ROMAN MEDIUM, FLUSH

LEFT, (SG1)

6" PICTOGRAM, (SG2)

1" TACTILE TEXT,

HELEVTICA NEUE, 55

ROMAN MEDIUM,

CENTERED (SG1)

1/4" 8 1/2" 1/4"

1'

2"

WOMEN

BACKGROUND, (SG2)

BACKGROUND, (SG2)

BRAILLE, TYPE II

BRAILLE, TYPE II

BACKGOUND, (SG1)

TA

C

TI

LE

C H

AR

AC

TE

R

" A

FF

T

O T

H E

BO

TT

O M

O F

LO

W

ES

T

9"

TA

C

TI

LE

C H

AR

AC

TE

R

" A

FF

T

O T

H E

BO

TT

O M

O F

LO

W

ES

T

9"

TA

C

TI

LE

C H

AR

AC

TE

R

" A

FF

T

O T

H E

BO

TT

O M

O F

LO

W

ES

T

9"

FIRE

RISER

2" APPLIED WHITE VINYL COPY,

HELVETICA NEUE, 85 HEAVY

(MINIMUM 3/8" STROKE)

SIGN FACE TO

BE SAFETY RED

1'-0"

8"

NOTE: EXTERIOR SIGNS

SHALL BE CONSTRUCTED

AND INSTALLED USING

EXTERIOR GRADE

MATERIALS.

9" (229 mm)

EMERGENCY

SHOWER &

EYEWASH

BACKGROUND, SAFETY

GREEN

PICTOGRAPH, WHITE

BACKGROUND, WHITE

3/4" TEXT, SAFETY

GREEN

4" (1 m m)9" (2 m m)

1/4" (6 mm) 8 1/2" (216 mm) 1/4" (6 mm)

REMOVABLE END

CAPS, BLACK

NOTE: SIGN SHALL BE CONSTRUCTED

AND INSTALLED WITH EXTERIOR

GRADE MATERIALS

3"

1/

2"

DIRECT PRINT

GRAPHIC

6"

9"

NO SMOKING

EXTERIOR GRADE

METAL PANEL, WHITE

3/4" TEXT, HELVETICA

NEUE 55 ROMAN, BLACK

PICTOGRAPH, BLACK

WITHIN 50 FEET OF BUILDING

3/4" 4 1/2" 3/4"

1/ 2"

1/

2" 1/

4"

*EXTERIOR GRADE

MATERIALS

PICTOGRAPH, RED

SMOKING PERMITTED IN

DESIGNATED SMOKING

AREAS ONLY

1/4" TEXT, HELVETICA

NEUE 55 ROMAN, BLACK

DANGER

HAZARDOUS AREA

STAND CLEAR DURING

DOOR OPERATIONS

HEADER BACKGROUND,

BLACK

2-1/2" TEXT, HELVETICA

BOLD UPPERCASE, WHITE

.040 MIN. EXTERIOR GRADE

PAINTED ALUMINUM SIGN

SUBSTRATE, NON-REFLECTIVE

WHITE BACKGROUND

1-1/4" TEXT, BOLD

UPPERCASE, BLACK

1'

- 2

EQ 1' - 8" EQ

MO

UN

T

AT

5'- 0"

A

FF

NOTE: SIGNAGE TO BE OSHA COMPLIANT, PROVIDE FADE RESISTANT,

ABRASION RESISTANT FINISH. GRAPHICS ARE DIRECT PRINT TO PANEL.

CENTER SIGN ON HANGAR

DOOR LEAF OR

STRUCTURAL COLUMN,

REFERENCE SIGNAGE

PLACEMENT PLANS FOR

MOUNTING LOCATIONS

TEXT BACKGROUND, RED

(BACKGROUND SHALL BE SOLID

COLOR FILL, DIAGONAL HATCH

PATTERN IS FOR GRAPHIC

CLARITY ONLY)

2' -0

SE

E

PL

U M

BI

N

G

SIGN

EYE

WASH

FINISHED

FLOOR

MENS

LOCKER ROOM

1/4" 8 1/2" 1/4"

1'

- 2

PICTOGRAPH

SYMBOL, (SG2)

BACKGROUND,

(SG2)

5/8" TACTILE TEXT,

HELVECTICA NEUE,

65 MEDIUM,

CENTERED (SG1)

GRADE II

BRAILLE

8"

9"

REMOVABLE

END CAPS, (SG3)

3/8 " C

LR

CL

R

3/8

3"

3"XXX

1 1/2" TACTILE

TEXT, HELVECTICA

NEUE, 65 MEDIUM,

FLUSH LEFT (SG1)

BACKGROUND,

(SG1)

WOMENS

LOCKER ROOM

1/4" 8 1/2" 1/4"

PICTOGRAPH

SYMBOL, (SG2)

BACKGROUND,

(SG1)

5/8" TACTILE TEXT,

HELVECTICA NEUE, 65

MEDIUM, CENTERED (SG1)

GRADE II

BRAILLE

9"

REMOVABLE

END CAPS, (SG3)

3/8 " C

LR

CL

R 3/8

3" 8"

3"

BACKGROUND,

(SG2)

XXX

1 1/2" TACTILE

TEXT, HELVECTICA

NEUE, 65 MEDIUM,

FLUSH LEFT (SG1)

BACKGROUND,

(SG2)

9'

- 0

SCHEDULED

SIGN

CENTERLINE OF

FIRE

EXTINGUISHER

FIRE

EXTINGUISHER

FINISHED

FLOOR

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

20190320

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

TX

AN

G Pr oje ct

Nu mb er:

K

EL

L 1

JB

SA

Ke lly

A nn ex , T

X

Te xa s A ir

Na tio na l G ua rd

9t h

FW

Co rro sio n C on tro l F ac ilit y

NDM

A

B C D

A B C D

E F G H

E F G

H I

I

C :\U sers\kxd\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_kdespainN

TT3U

.rvt

8/1/2024 9:41:29 AM

2 AUGUST 2024

IG-501

SIGNAGE DETAILS AND

ELEVATIONS

BKG

KAH

KAH

SCALE 3" = 1'-0"

SIGN TYPE 1A1 SCALE 3" = 1'-0"

SIGN TYPE 2C1

SCALE 3" = 1'-0"

SIGN TYPE 3E1

SCALE 3" = 1'-0"

SIGN TYPE 4A3

SCALE 1/2" = 1'-0"

SIGN MOUNTING -

TYPE 1E6 SCALE 1/2" = 1'-0"

SIGN MOUNTING -

TYPE 2 / 3 / 5F6 SCALE 1/2" = 1'-0"

SIGN MOUNTING -

TYPE 4G6

3" 9"6"0

3" = 1'-0"

0 1' 2' 4'

1/2" = 1'-0"

SCALE 3" = 1'-0"

SIGN TYPE 5

FIRE RISER ROOME3

GENERAL NOTES

A. REFER TO SHEETS IG-101 FOR SIGNAGE SCHEDULE,

ELEVATIONS, AND DETAILS.

B. CONTRACTOR IS IS TO VERIFY FINAL DIMENSIONS,

MATERIALS, FINISHES, AND ROOM NAMES /

NUMBERS WITH CONTRACTING OFFICER'S

TECHNICAL REPRESENTATIVE PRIOR TO

PROCUREMENT OF SIGNAGE.

C. FOR SIGNS MOUNTED TO GLASS, PROVIDE A

MATCHING OPAQUE FILM ON REVERSE SIDE OF

GLASS TO CONCEAL MOUNTING TAPE. COLOR TO

MATCH SIGN.

D. SIGNS MUST MEET ABA REQUIREMENTS.

E. SIGNS MUST COMPLY WITH UFC 3-120-01 DESIGN:

SIGN STANDARDS.

F. SIGNAGE PLAN AND SCHEDULES DO NOT INCLUDE

REGULATORY LABELING, ILLUMINATED EXIT SIGNS,

AND/OR HAZARD WARNINGS WHICH MAY BE

REQUIRED BY BUILDING AND/OR FIRE CODE.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING

ANY SUCH LABELING IN ACCORDANCE WITH

ADOPTED BUILDING CODES AND AS SPECIFIED BY

FIRE PROTECTION, ELECTRICAL, MECHANICAL,

AND/OR PLUMBING ENGINEER.

G. SIGNAGE PLAN AND SCHEDULES DO NOT INCLUDE

LABELING THAT MAY BE REQUIRED AT SOME DOOR

HARDWARE ELEMENTS, SUCH AS AUTOMATIC DOOR

OPERATORS OR EMERGENCY PANIC BARS. REFER

TO DOOR HARDWARE SPECIFICATIONS AND

ANSI/BHMA STANDARDS FOR REQUIRED LABELING

AT DOOR HARDWARE.

SCALE 3" = 1'-0"

SIGN TYPE 7

EMERGENCY EYEWASH STATIOND4 SCALE 3" = 1'-0"

SIGN TYPE 8E4 SCALE 3" = 1'-0"

SIGN TYPE 9G4

SCALE 3" = 1'-0"

SIGN TYPE 6

DANGER - HANGAR DOOR OPERATIONB4

SCALE 1/2" = 1'-0"

SIGN MOUNTING -

EYE WASHD6

SCALE 3" = 1'-0"

SIGN TYPE 10

LOCKER ROOM / SHOWER (MEN, ADA)A6

SCALE 1/2" = 1'-0"

SIGN MOUNTING - FEXF4

JASON

MARK

ELLIOTT

3071933071933