This document is a specification for door hardware for the Construct Corrosion Control Facility project. It details the requirements for hinges, locks, exit devices, closers, weatherstripping, and other hardware components. Key details include:

The specification covers door hardware requirements such as hinges, locks, exit devices, closers, weatherstripping, and other components. It references applicable industry standards and provides detailed requirements for each hardware item, including finish, function, and compatibility with the facility's keying system. The hardware must meet accessibility, fire safety, and security requirements. The contractor is required to submit shop drawings, product data, and a hardware schedule for government approval. Provisions are included for installation, field quality control, and coordination with the facility's intrusion detection and access control systems.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Corrosion Control Facility, newest first.
File Type Posted
Corrosion Control Facility - Abstract of Bidders - REVISED - 20240924.pdf PDF
Corrosion Control Facility - Abstract of Bidders 20240918.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 05 - 20240913.pdf PDF
Addendum 3 - S-001-GENERAL NOTES.pdf PDF
Addendum 3 - SB507-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB506-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB508-FOUNDATION DETAILS.pdf PDF
Addendum 3 - SB102-SLAB PLAN.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 04 - 20240910.pdf PDF
Addendum 3 - G-203-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-500-DETAILS.pdf PDF
Addendum 3 - A-103-ROOF PLAN.pdf PDF
Addendum 3 - A-101-FLOOR PLAN.pdf PDF
Addendum 03 Cover Page.pdf PDF
Attachment 13 - Kelly Annex CORROSION CONTROL-TOPO.pdf PDF
Addendum 3 - G-002-SHEET INDEX.pdf PDF
Addendum 3 - EG502-GROUNDING AND LIGHTNING PROTECTION DETAILS.pdf PDF
Addendum 3 - A-104-HANGAR BAY FLOOR PAINT STRIPING PLAN.pdf PDF
Addendum 3 - 09 06 00 - SCHEDULES OF FINISHES.pdf PDF
Addendum 3 - 08 34 16.10 - HORIZONTAL ROLLING STEEL DOORS.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 230 (20240910).pdf PDF
Attachment 12 - JBSA-Soil Management Plan - Signed Jan 22.pdf PDF
Addendum 3 - G-201-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-501-DETAILS.pdf PDF
Addendum 3 - G-202-SPECIAL INSPECTIONS.pdf PDF
Addendum 3 - A-201-BUILDING ELEVATIONS.pdf PDF
Addendum 3 - 01 14 00 - WORK RESTRICTIONS.pdf PDF
ADDENDUM 2- SPECIFICATIONS -08 34 16.10 -- DRAWING - A-603.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 03 - 20240905.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 11 (20240829).pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 02 - 20240829.pdf PDF
Attachment 11 - Geotechical report - TX ANG CC Facility.pdf PDF
W50S7824B0002 - Corrosion Control - Amendment 01 - 20240823.pdf PDF
W50S7824B0002 - Corrosion Control - RFI Responses 1 - 5 (20240823).pdf PDF
Pre-Proposal Site Visit Slides_Corrosion Control 20 Aug 24.pptx PPTX presentation
Pre_Bid_Site Visit_Corrosion Control_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 1 - TX-ANG_CORROSION CONTRAOL HANGAR_TYPE B3_DRAWINGS.pdf PDF
Attachment 1.a. - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_DRAWINGS (1-74) 2024.08.02.pdf PDF
Attachment 10 - Monaco Redacted.pdf PDF
W50S7824B0002 Corrosion Control Facility -Solicitation - 20240809.pdf PDF
Attachment 3 - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_VOL 2 SPECIFICATIONS 2024.08.02.pdf PDF
Attachment 4 - STRUCTURAL INTERIOR DESIGN.pdf PDF
Attachment 9 - Falcon Redacted.pdf PDF
Attachment 1.b. - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_DRAWINGS (75-136) 2024.08.02.pdf PDF
Attachment 2 - TX-ANG_CORROSION CONTROL HANGAR_TYPE B3_VOL 1 SPECIFICATIONS 2024.08.02.pdf PDF
Attachment 6 - Access and staging site plan.pdf PDF
Attachment 5 - Industrial Security SOW.pdf PDF
Attachment 7 - DDC Redacted.pdf PDF
Attachment 8 - Trane Redacted.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FSB | fsb-ae.com

ADDENDUM NO. 01

Date: 21 August 2024

To: ALL BIDDERS OF RECORD

From: Frankfurt-Short-Bruza Associates, P.C.

5801 N. Broadway Ext., Suite 500 Oklahoma City, OK 73118

Subject: KELL169014: Construct Corrosion Control Facility, TX/ANG, JBSA Lackland, San Antonio, TX

FSB Project No.: 20190320

NOTE: This Addendum forms a part of the Contract Documents and modifies the Original Documents dated 2 August 2024.

Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification.

ATTACHMENTS

Items in this addendum take precedence over the original bid documents. Items not specifically revised remain in effect. This addendum consists of (1) pages and the following attachments:

Specifications:

08 71 00 – DOOR HARDWARE

MODIFICATIONS TO THE SPECIFICATIONS

ITEM 01.1-1 Refer to attached Specification Section 08 71 00 – DOOR HARDWARE, dated 21 August 2024:

A. Specification Section 08 71 00 is hereby revised and re-issued in its entirety to remove BEST lockset system as specific product & revise number of tumblers. Replace Section 08 71 00 dated 2 August 2024 with attached revised

Specification Section 08 71 00dated 21 August 2024.

NGBJV/ TX CORROSI ON CONTROL FACI LI TY PN KELL169014

KELLY FI ELD ANNEX B- 3 SUBMI SSI ON, 02 AUGUST, 2024

SECTI ON 08 71 00

DOOR HARDWARE

02/ 16, CHG 4: 02/ 22

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

ASTM I NTERNATI ONAL ( ASTM)

ASTM E283 ( 2019) St andar d Test Met hod f or Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men

ASTM F883 ( 2013; R 2022) St andar d Per f or mance Speci f i cat i on f or Padl ocks

BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)

ANSI / BHMA A156. 1 ( 2021) But t s and Hi nges

ANSI / BHMA A156. 2 ( 2022) Bor ed and Pr eassembl ed Locks and Lat ches

ANSI / BHMA A156. 3 ( 2020) Exi t Devi ces

ANSI / BHMA A156. 4 ( 2013) Door Cont r ol s - Cl oser s

ANSI / BHMA A156. 5 ( 2020) Cyl i nder and I nput Devi ces f or Locks

ANSI / BHMA A156. 6 ( 2021) Ar chi t ect ur al Door Tr i m

ANSI / BHMA A156. 7 ( 2016) Templ at e Hi nge Di mensi ons

ANSI / BHMA A156. 8 ( 2021) Door Cont r ol s - Over head St ops and Hol der s

ANSI / BHMA A156. 10 ( 2017) Power Oper at ed Pedest r i an Door s

ANSI / BHMA A156. 13 ( 2022) Mor t i se Locks & Lat ches Ser i es 1000

ANSI / BHMA A156. 14 ( 2013) Sl i di ng and Fol di ng Door Har dwar e

ANSI / BHMA A156. 15 ( 2021) Rel ease Devi ces Cl oser Hol der , El ect r omagnet i c and El ect r omechani cal

ANSI / BHMA A156. 16 ( 2023) Auxi l i ar y Har dwar e

ANSI / BHMA A156. 17 ( 2019) Sel f Cl osi ng Hi nges & Pi vot s

ANSI / BHMA A156. 18 ( 2020) Mat er i al s and Fi ni shes

SECTI ON 08 71 00 Page 1

Addendum #1 - 08/21/2024

Estrada, Oscar A.

Cloud

ANSI / BHMA A156. 21 ( 2019) Thr eshol ds

ANSI / BHMA A156. 22 ( 2021) Gasket i ng

ANSI / BHMA A156. 23 ( 2010) El ect r omagnet i c Locks

ANSI / BHMA A156. 24 ( 2012) Del ayed Egr ess Locki ng Syst ems

ANSI / BHMA A156. 25 ( 2013) El ect r i f i ed Locki ng Devi ces

ANSI / BHMA A156. 26 ( 2012) Cont i nuous Hi nges

ANSI / BHMA A156. 29 ( 2012) Exi t Locks, Exi t Al ar ms, Al ar ms f or Exi t Devi ces

ANSI / BHMA A156. 30 ( 2014) Hi gh Secur i t y Cyl i nder s

ANSI / BHMA A156. 31 ( 2013) El ect r i c St r i kes and Fr ame Mount ed Act uat or s

ANSI / BHMA A156. 36 ( 2010) Auxi l i ar y Locks

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 70 ( 2023; ERTA 7 2023; TI A 23- 15) Nat i onal El ect r i cal Code

NFPA 72 ( 2022; ERTA 22- 1) Nat i onal Fi r e Al ar m and Si gnal i ng Code

NFPA 80 ( 2022) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves

NFPA 101 ( 2021; TI A 21- 1) Li f e Saf et y Code

NFPA 252 ( 2022) St andar d Met hods of Fi r e Test s of Door Assembl i es

STEEL DOOR I NSTI TUTE ( SDI / DOOR)

SDI / DOOR A250. 8 ( 2023) Speci f i cat i ons f or St andar d St eel Door s and Fr ames

U. S. GENERAL SERVI CES ADMI NI STRATI ON ( GSA)

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

36 CFR 1191 Amer i cans wi t h Di sabi l i t i es Act ( ADA) Accessi bi l i t y Gui del i nes f or Bui l di ngs and Faci l i t i es; Ar chi t ect ur al Bar r i er s Act ( ABA) Accessi bi l i t y Gui del i nes

UNDERWRI TERS LABORATORI ES ( UL)

UL Bl d Mat Di r ( updat ed cont i nuousl y onl i ne) Bui l di ng Mat er i al s Di r ect or y

SECTI ON 08 71 00 Page 2

1. 2 SUBMI TTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" c l assi f i cat i on. Submi t t al s not havi ng a " G" or " S" c l assi f i cat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t al s wi t h an " S" c l assi f i cat i on ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance t o Sect i on 01 33 29 SUSTAI NABI LI TY REQUI REMENTS AND REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Manuf act ur er ' s Det ai l Dr awi ngs; G

Ver i f i cat i on of Exi st i ng Condi t i ons; G

Har dwar e Schedul e; G

Keyi ng Syst em; G

SD- 03 Pr oduct Dat a

Har dwar e I t ems; G

SD- 08 Manuf act ur er ' s I nst r uct i ons

I nst al l at i on

SD- 10 Oper at i on and Mai nt enance Dat a

Har dwar e Schedul e I t ems, Dat a Package 1; G

SD- 11 Cl oseout Submi t t al s

Key Bi t t i ng

1. 3 SHOP DRAWI NGS

Submi t manuf act ur er ' s det ai l dr awi ngs i ndi cat i ng al l har dwar e assembl y component s and i nt er f ace wi t h adj acent const r uct i on. I ndi cat e power component s and wi r i ng coor di nat i on f or el ect r i f i ed har dwar e. Base shop dr awi ngs on ver i f i ed f i el d measur ement s and i ncl ude ver i f i cat i on of exi st i ng condi t i ons.

1. 4 PRODUCT DATA

I ndi cat e f i r e- r at i ngs at appl i cabl e component s. Pr ovi de document at i on of ABA/ ADA accessi bi l i t y compl i ance of appl i cabl e component s, as r equi r ed by 36 CFR 1191 Appendi x D - Techni cal .

1. 5 HARDWARE SCHEDULE

Pr epar e and submi t har dwar e schedul e i n t he f ol l owi ng f or m:

SECTI ON 08 71 00 Page 3

Har dwar e I t em

Quant i t y Si ze Ref er ence Publ i -cat i on Type No.

Fi ni sh Mf r Name and Cat al og No.

Key Cont r ol Symbol s

UL

Mar k ( I f f i r e-r at ed and l i st ed)

BHMA

Fi ni sh Desi g-nat i on

I n addi t i on, submi t har dwar e schedul e dat a package 1 i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND MAI NTENANCE DATA.

1. 6 KEY BI TTI NG CHART REQUI REMENTS

Coor di nat e door cyl i nder and keyi ng r equi r ement s wi t h t he Joi nt Base San Ant oni o l ock shop per sonnel , POC i nf or mat i on l i s t ed bel ow i n t hi s speci f i cat i on. Conf i gur e cor es and cut keys t o Joi nt Base San Ant oni o l ock shop speci f i cat i ons and mast er keyi ng st r at egy. Conf i gur ed cor es and cut keys shal l be del i ver ed wi t h key bi t t i ng char t ( s) t o t he Joi nt Base San Ant oni o l ock shop f or f i nal i nst al l at i on. Fi nal l ockset cor e i nst al l at i on wi l l be conduct ed by Joi nt Base San Ant oni o per sonnel .

1. 6. 1 Requi r ement s

Submi t key bi t t i ng char t s t o t he Cont r act i ng Of f i cer pr i or t o compl et i on of t he wor k. I ncl ude:

1. Compl et e l i s t i ng of al l keys ( e. g. AA1 and AA2) .

2. Compl et e l i s t i ng of al l key cut s ( AA1- 123456, AA2- 123458) .

3. Tabul at i on showi ng whi ch key f i t s whi ch door .

4. Copy of f l oor pl an showi ng door s and door number s.

5. Li st i ng of 20 per cent mor e key cut s t han ar e pr esent l y r equi r ed i n each mast er syst em.

1. 7 QUALI TY ASSURANCE

1. 7. 1 Har dwar e Manuf act ur er s and Modi f i cat i ons

Pr ovi de, as f ar as f easi bl e, l ocks, hi nges, pi vot s, and cl oser s of one l ock, hi nge, pi vot , or c l oser manuf act ur er ' s make. Modi f y har dwar e as necessar y t o pr ovi de f eat ur es i ndi cat ed or speci f i ed.

1. 7. 2 Key Shop Dr awi ngs Coor di nat i on Meet i ng

Pr i or t o t he submi ssi on of t he key shop dr awi ng, t he Cont r act i ng Of f i cer , Cont r act or , Door Har dwar e Subcont r act or , usi ng Act i v i t y and Base Locksmi t h must meet t o di scuss and coor di nat e key r equi r ement s f or t he f aci l i t y .

1. 8 DELI VERY, STORAGE, AND HANDLI NG

Del i ver har dwar e i n or i gi nal i ndi v i dual cont ai ner s, compl et e wi t h necessar y appur t enances i ncl udi ng f ast ener s and i nst r uct i ons. Mar k each i ndi v i dual cont ai ner wi t h i t em number as shown on har dwar e schedul e.

SECTI ON 08 71 00 Page 4

PART 2 PRODUCTS

2. 1 TEMPLATE HARDWARE

Har dwar e appl i ed t o met al door s must be manuf act ur ed usi ng a t empl at e.

Pr ovi de t empl at es t o door and f r ame manuf act ur er s i n accor dance wi t h ANSI / BHMA A156. 7 f or t empl at e hi nges. Coor di nat e har dwar e i t ems t o pr event i nt er f er ence wi t h ot her har dwar e.

2. 2 HARDWARE FOR FI RE DOORS AND EXI T DOORS

Pr ovi de al l har dwar e necessar y t o meet t he r equi r ement s of NFPA 72 f or door al ar ms, NFPA 80 f or f i r e door s, NFPA 101 f or exi t door s, NFPA 252 f or f i r e t est s of door assembl i es, ABA/ ADA accessi bi l i t y r equi r ement s, and al l ot her r equi r ement s i ndi cat ed, even i f such har dwar e i s not speci f i cal l y ment i oned i n par agr aph HARDWARE SCHEDULE. Pr ovi de Under wr i t er s Labor at or i es, I nc. l abel s f or such har dwar e i n accor dance wi t h UL Bl d Mat Di r or equi val ent l abel s i n accor dance wi t h anot her t est i ng l abor at or y appr oved i n wr i t i ng by t he Cont r act i ng Of f i cer .

2. 3 HARDWARE I TEMS

Cl ear l y and per manent l y mar k wi t h t he manuf act ur er ' s name or t r ademar k, hi nges, pi vot s, l ocks, l at ches, exi t devi ces, bol t s and cl oser s wher e t he i dent i f y i ng mar k i s v i s i bl e af t er t he i t em i s i nst al l ed. For c l oser s wi t h cover s, t he name or t r ademar k may be beneat h t he cover . Coor di nat e el ect r i f i ed door har dwar e component s wi t h cor r espondi ng component s speci f i ed i n Di v i s i on 28 ELECTRONI C SECURI TY SYSTEMS ( ESS) .

2. 3. 1 Hi nges

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 1. Pr ovi de hi nges t hat ar e 4- 1/ 2 by 4- 1/ 2 i nch unl ess ot her wi se i ndi cat ed. Const r uct l oose pi n hi nges f or ext er i or door s and r ever se- bevel i nt er i or door s so t hat pi ns wi l l be nonr emovabl e when door i s c l osed. Use BHMA t ype 5111 heavy wei ght ant i f r i c t i on bear i ng hi nges on ext er i or door s and door s exposed t o t he hangar bays. Use BHMA t ype 8111 heavy wei ght ant i f r i c t i on bear i ng hi nges on i nt er i or door s t hat f or m par t of t he bui l di ng c i r cul at i on syst ems, secur e st or age and pr i mar y shop door s. Use BHMA t ype 8112 on pr i mar y of f i ce sui t e door s, conf er ence, br i ef i ng and al l ot her door s not i ncl uded above t hat ar e equi pped wi t h c l oser s. Use BHMA t ype 8131 on al l ot her door s. Ot her ant i f r i c t i on bear i ng hi nges may be pr ovi ded i n l i eu of bal l - bear i ng hi nges.

2. 3. 1. 1 Maxi mum Secur i t y Pi n ( MSP)

ANSI / BHMA A156. 1 Pr ovi de Maxi mum Secur i t y pi ns and secur i t y st uds at al l hi nges i dent i f i ed as " wi t h MSP" i n t he har dwar e schedul e.

2. 3. 1. 2 Non- Removeabl e Pi n ( NRP)

ANSI / BHMA A156. 1 Pr ovi de at al l hi nges i dent i f i ed as " wi t h NRP" i n t he har dwar e schedul e.

2. 3. 2 Cont i nuous Hi nges

Wher e cont i nuous hi nges ar e r equi r ed, pr ovi de i n accor dance wi t h

ANSI / BHMA A156. 26.

SECTI ON 08 71 00 Page 5

2. 3. 3 Spr i ng Hi nges

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 17.

2. 3. 4 Locks and Lat ches

1. At ext er i or l ocat i ons pr ovi de l ockset s of f ul l s t ai nl ess st eel t ype 302 or 304 const r uct i on i ncl udi ng f r ont s, st r i ke, escut cheons, knobs, bol t s and al l i nt er i or wor ki ng par t s. Mar i ne Gr ade I , f ul l y non- f er r ous.

2. I n non- ai r - condi t i oned i nt er i or envi r onment s or humi d i nt er i or envi r onment s, pr ovi de i nt er i or l ockset s on t he same Mar i ne Gr ade I , f ul l y non- f er r ous as ext er i or l ockset s.

2. 3. 4. 1 Auxi l i ar y Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 36, Gr ade 1. compat i bl e wi t h Joi nt Base San Ant oni o keyi ng syst em. Pr ovi de speci al f eat ur es when descr i bed i n t he har dwar e schedul e.

2. 3. 4. 2 5- But t on Mechani cal Lockset s

ANSI / BHMA A156. 5, Funct i on 40. Lockset pr ovi ded shal l be r at ed f or out door use and be door syst em compat i bl e. Lock shal l be mechani cal , 5- push but t on t ype, wi t h l ever handl e ( bot h s i des of door , unl ess not ed ot her wi se) and keyed cyl i ndr i cal cor e, compat i bl e wi t h Joi nt Base San Ant oni o keyi ng syst em. Lockset shal l be i nst al l ed i n a manner t hat i s per manent , st ur dy, and t hat does not al l ow access t o t he l at ch r el ease f r om t he unsecur e s i de.

2. 3. 4. 3 Bor ed Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 2, Ser i es 4000, Gr ade 1.

compat i bl e wi t h Joi nt Base San Ant oni o keyi ng syst em

2. 3. 4. 4 Mor t i se Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 13, Ser i es 1000, Oper at i onal Gr ade 1, Secur i t y Gr ade 2. compat i bl e wi t h Joi nt Base San Ant oni o keyi ng syst em Pr ovi de mor t i se l ocks wi t h escut cheons not l ess t han 7 by 2- 1/ 4 i nch wi t h a bushi ng at l east 1/ 4 i nch l ong. Cut escut cheons t o f i t cy l i nder s and pr ovi de t r i m i t ems wi t h st r ai ght , bevel ed, or smoot hl y r ounded si des, cor ner s, and edges. Pr ovi de l ever s of mor t i se l ocks wi t h scr ewl ess shanks and no exposed scr ews.

2. 3. 5 Exi t Devi ces

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3, Gr ade 1. Pr ovi de adj ust abl e st r i kes f or r i m t ype and ver t i cal r od devi ces. Pr ovi de open back st r i kes f or pai r s of door s wi t h mor t i se and ver t i cal r od devi ces. Pr ovi de

2. 3. 5. 1 El ect r i c Exi t Devi ces

Pr ovi de el ect r i c act uat ed exi t devi ces wher e i dent i f i ed i n t he har dwar e schedul e. Gr ade and f i ni sh shal l be s i mi l ar t o mechani cal devi ces pr ovi ded t hr oughout t he bui l di ng.

SECTI ON 08 71 00 Page 6

2. 3. 6 Exi t Locks Wi t h Al ar m

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3 and ANSI / BHMA A156. 29, Type E0431 ( wi t h f ul l wi dt h hor i zont al act uat i ng bar ) f or s i ngl e door s; Type E0431 ( wi t h act uat i ng bar ) or E0471 ( wi t h act uat i ng bar and t op and bot t om bol t s, bot h l eaves act i ve) f or pai r s of door s, unl ess ot her wi se speci f i ed.

Pr ovi de t er mi nal s f or connect i on t o r emot e i ndi cat i ng panel . Pr ovi de out si de cont r ol key. Pr ovi de door al ar ms i nt egr at ed wi t h t he f i r e al ar m syst em i n accor dance wi t h NFPA 72.

2. 3. 7 Cyl i nder s and Cor es

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven six pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer.

Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Factory set the cores with seven six pin tumblers using the A4 system and F keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.2.3.7.1 High

Security Cylinders

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 30, secur i t y l evel ABC f or al l hi gh secur i t y cyl i nder component s.

2. 3. 8 Push But t on Mechani sms

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5, Gr ade 1.

2. 3. 9 El ect r i f i ed Har dwar e

Compl y wi t h t he r equi r ement s of NFPA 70 f or wi r i ng of el ect r i f i ed har dwar e.

2. 3. 9. 1 El ect r i c St r i kes and Fr ame Mount ed Act uat or s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 31, Gr ade 1. Pr ovi de el ect r i c st r i kes and act uat or s as r equi r ed t o meet oper at i onal r equi r ement s.

Pr ovi de el ect r i c st r i kes t hat r emai n secur e dur i ng power f ai l ur e. Pr ovi de a separ at e power suppl y f or el ect r i c st r i kes, ot her l ocki ng devi ces and anci l l ar y par t s. Pr ovi de st r i kes and act uat or s wi t h a mi ni mum openi ng f or ce of 2300 pounds.

Pr ovi de f aci l i t y i nt er f ace devi ces t hat use di r ect cur r ent ( dc) power t o ener gi ze t he sol enoi ds. Pr ovi de el ect r i c st r i kes and act uat or s t hat i ncor por at e end- of - l i ne r esi st or s t o f aci l i t at e l i ne super vi s i on by t he syst em. I f not i ncor por at ed i nt o t he el ect r i c st r i ke or l ocal cont r ol l er , pr ovi de met al oxi de r esi st or s ( MOVs) t o pr ot ect t he cont r ol l er f r om r ever se cur r ent sur ges.

2. 3. 9. 1. 1 Sol enoi d

Pr ovi de act uat i ng sol enoi d f or st r i kes and act uat or s t hat ar e r at ed f or cont i nuous dut y, cannot di ssi pat e mor e t han 12 Wat t s and must oper at e on 12 or 24 Vol t s dc. I nr ush cur r ent cannot exceed 1 amper e and t he hol di ng cur r ent cannot be gr eat er t han 500 mi l l i amper es. Act uat i ng sol enoi d must

SECTI ON 08 71 00 Page 7

Addendum #1 - 08/21/2024

Estrada, Oscar A.

Cloud move f r om f ul l y secur e t o f ul l y open posi t i ons i n l ess t han 500 mi l l i seconds.

2. 3. 9. 1. 2 Si gnal Swi t ches

Pr ovi de st r i kes and act uat or s wi t h s i gnal swi t ches t o i ndi cat e t o t he syst em when t he bol t i s not engaged or t he st r i ke mechani sm i s unl ocked.

Si gnal swi t ches must r epor t a f or ced ent r y t o t he syst em.

2. 3. 9. 1. 3 Tamper Resi st ance

Pr ovi de st r i ke guar ds t hat pr event t amper i ng wi t h t he l at ch bol t of t he l ocki ng har dwar e or t he l at ch bol t keeper of t he el ect r i c st r i ke. St r i ke guar ds t o bol t t hr ough t he door usi ng t amper r esi st ant scr ews. Pr ovi de st r i ke guar ds made of 1/ 8 i nch t hi ck br ass and t hat ar e 11- 1/ 14 i nch hi gh by 1- 5/ 8 i nch wi de, wi t h a mi ni mum 5/ 32 i nch wi de of f set .

2. 3. 9. 1. 4 Coor di nat i on

Pr ovi de el ect r i c st r i kes and act uat or s of a s i ze, wei ght and pr of i l e compat i bl e wi t h each speci f i ed door f r ame. Fi el d ver i f y i nst al l at i on c l ear ances pr i or t o pr ocur ement .

2. 3. 9. 1. 5 Mount i ng Met hod

Pr ovi de el ect r i c st r i kes and act uat or s sui t abl e f or use wi t h s i ngl e and doubl e door s, wi t h mor t i se or r i m t ype har dwar e speci f i ed, and f or r i ght or l ef t hand mount i ng as speci f i ed. I n doubl e door i nst al l at i ons, l ocat e t he l ock i n t he act i ve l eaf and moni t or t he f i xed l eaf .

2. 3. 9. 2 El ect r i f i ed Mor t i se Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 25, Gr ade 1. Pr ovi de el ect r i f i ed mor t i se l ocks t hat r emai n secur e dur i ng power f ai l ur e.

Pr ovi de f aci l i t y i nt er f ace devi ces t hat use dc power t o ener gi ze sol enoi ds. Pr ovi de sol enoi ds, r esi st er s, and si gnal swi t ches i n accor dance wi t h par agr aph ELECTRI C STRI KES AND FRAME MOUNTED ACTUATORS.

2. 3. 9. 2. 1 Power Tr ansf er Hi nges

Pr ovi de power t r ansf er hi nges wi t h each el ect r i f i ed l ock t hat r out e power and moni t or i ng s i gnal s f r om t he l ockset t o t he door f r ame. Coor di nat e power t r ansf er hi nges wi t h door f r ames.

2. 3. 9. 3 Car d Reader s and Keypad Access Cont r ol Har dwar e

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5 and ANSI / BHMA A156. 25, Gr ade 1 component s. Pr ovi de devi ces t hat ar e t amper al ar med, t amper and vandal r esi st ant , sol i d st at e, and do not cont ai n el ect r oni cs whi ch coul d compr omi se t he access cont r ol subsyst em shoul d t he subsyst em be at t acked.

Pr ovi de sur f ace, semi - f l ush, pedest al , or weat her pr oof mount abl e devi ces as speci f i ed f or each i ndi v i dual l ocat i on. Each devi ce t o cont ai n a v i sual di spl ay, ei t her mount ed on t he f ace, or on an i nt egr al par t of t he devi ce, t o i ndi cat e access or exi t r equest pr ocessi ng, r equest appr oval , and r equest deni al . Pr ovi de pr oxi mi t y i nser t i on swi pe t hr ough t ype car d r eader s capabl e of r eadi ng magnet i c st r i pe hi gh coer ci v i t y magnet i c st r i pe Wi egand Hol l er i t h pr oxi mi t y Tr ansmi ssi ve I nf r ar ed Keypad Smar t Car d t ype access cont r ol car ds. Pr ovi de keypads t hat cont ai n an i nt egr al 12- di gi t t act i l e keyboar d wi t h di gi t s ar r anged i n numer i cal or der . Pr ovi de keypads

SECTI ON 08 71 00 Page 8 t hat ar e a st andal one devi ce or i nt egr at ed i nt o t he car d r eader .

Coor di nat e access cont r ol har dwar e wi t h cor r espondi ng devi ces and syst ems speci f i ed i n Di v i s i on 28 ELECTRONI C SECURI TY SYSTEMS ( ESS) .

2. 3. 9. 4 Power Oper at ed Pedest r i an Door Har dwar e

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 10, Gr ade 1.

2. 3. 9. 5 Rel ease Devi ces

I n accor dance wi t h ANSI / BHMA A156. 15, Gr ade 1.

2. 3. 9. 5. 1 Cl oser Hol der s

Pr ovi de mount ed cl oser hol der devi ces connect ed by i nt egr al r el easi ng t o det ect i ng devi ces.

2. 3. 9. 5. 2 Rel ease Devi ces

Pr ovi de mount ed r el ease devi ces connect ed t o det ect i ng devi ces.

2. 3. 9. 6 El ect r omagnet i c Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 23, Gr ade 1. Pr ovi de el ect r omagnet i c l ocks t hat do not cont ai n any movi ng par t s and depend sol el y upon el ect r omagnet i sm t o secur e a por t al by gener at i ng at l east 1200 pounds of hol di ng f or ce. The l ock must i nt er f ace wi t h t he l ocal pr ocessor s wi t hout ext er nal , i nt er nal or f unct i onal al t er at i on of t he l ocal pr ocessor . The el ect r omagnet i c l ock must i ncor por at e an end of l i ne r esi st or t o f aci l i t at e l i ne super vi s i on by t he syst em. Pr ovi de met al - oxi de r esi st or s ( MOVs) t o pr ot ect cont r ol l er s f r om r ever se cur r ent sur ges, i f not i ncor por at ed i nt o t he el ect r omagnet i c l ock or l ocal cont r ol l er .

2. 3. 9. 6. 1 Ar mat ur e

Pr ovi de el ect r omagnet i c l ocks wi t h i nt er nal c i r cui t r y t o el i mi nat e r esi dual magnet i sm and i nduct i ve k i ckback. Pr ovi de at uat i ng ar mat ur e t hat oper at es on 12 or 24 Vol t s dc and cannot di ssi pat e mor e t han 12 Wat t s.

Hol di ng cur r ent must be l ess t han 500 mi l l i amper es. Act uat i ng ar mat ur e must t ake l ess t han 300 mi l l i seconds t o change t he st at us of t he l ock f r om f ul l y secur e t o f ul l y open or f ul l y open t o f ul l y secur e.

2. 3. 9. 6. 2 Tamper Resi st ance

Pr ovi de l ock mechani sm encased i n har dened guar d bar r i er s t o det er f or ced ent r y.

2. 3. 9. 6. 3 Mount i ng Met hod

Pr ovi de el ect r omagnet i c l ock sui t abl e f or use wi t h s i ngl e and doubl e door wi t h mor t i se or r i m t ype har dwar e and compat i bl e wi t h r i ght or l ef t hand mount i ng.

2. 3. 9. 7 Del ayed Egr ess Locki ng Syst em

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 24, Gr ade 1.

SECTI ON 08 71 00 Page 9

2. 3. 10 Keyi ng Syst em

Pr ovi de a gr and mast er keyi ng syst em

Pr ovi de cyl i nder s of Gr ade 1 pr oduct s f r om one manuf act ur er . Not i f y t he Cont r act i ng Of f i cer 90 days pr i or t o t he r equi r ed del i ver y of t he cyl i nder s. Pr ovi de t empor ar y cor es and keys f or t he Cont r act or ' s use dur i ng const r uct i on, and f or t est i ng of l ockset s.

2. 3. 11 Lock Tr i m

Pr ovi de cast , f or ged, or heavy wr ought const r uct i on and commer ci al pl ai n desi gn f or l ock t r i m.

2. 3. 11. 1 Knobs and Roses

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 2 and ANSI / BHMA A156. 13 f or knobs, r oses, and escut cheons. For unr ei nf or ced knobs, r oses, and escut cheons, pr ovi de a 0. 050 i nch t hi ckness. For r ei nf or ced knobs, r oses, and escut cheons, pr ovi de an out er shel l t hi ckness of 0. 035 i nch and a combi ned t ot al t hi ckness of 0. 070 i nch, except at knob shanks. Pr ovi de knob shanks 0. 060 i nch t hi ck.

2. 3. 11. 2 Lever Handl es

Pr ovi de l ever handl es wher e i ndi cat ed i n t he Har dwar e Schedul e. Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3 f or mor t i se l ocks of l ever handl es f or exi t devi ces. Pr ovi de l ever handl e l ocks wi t h a br eakaway f eat ur e ( such as a weakened spi ndl e or a shear key) t o pr event i r r epar abl e damage t o t he l ock when f or ce i n excess of t hat speci f i ed i n ANSI / BHMA A156. 13 i s appl i ed t o t he l ever handl e. Pr ovi de l ever handl es r et ur n t o wi t hi n 1/ 2 i nch of t he door f ace.

2. 3. 12 Keys

Fur ni sh one f i l e key, one dupl i cat e key, and one wor ki ng key f or each key change and f or each mast er and gr and mast er keyi ng syst em. Fur ni sh one addi t i onal wor ki ng key f or each l ock of each keyed- al i ke gr oup. Fur ni sh t wo gr eat gr and mast er keys, t wo const r uct i on mast er keys, . Fur ni sh a quant i t y of key bl anks equal t o 20 per cent of t he t ot al number of f i l e keys. St amp each key wi t h appr opr i at e key cont r ol symbol and " U. S.

pr oper t y - do not dupl i cat e. " Do not pl ace r oom number on keys.

Furnish seven change keys for each interchangeable core, furnish two control keys, six maters keys, and six construction master keys. Furnish a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S.

property - do not duplicate." Do not place room numbers on keys.

Coordinate with Buckley ASSF 149 Civil Engineer Squadron Base lock shop personnel. Cut keys to Buckley ASSF 149 Civil Engineer Squadron Base lock shop specifications.

2. 3. 13 Door Bol t s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16. Pr ovi de dust pr oof st r i kes f or bot t om bol t s, except at door s havi ng met al t hr eshol ds. Pr ovi de aut omat i c l at chi ng f l ush bol t s i n accor dance wi t h ANSI / BHMA A156. 3, Type 25.

SECTI ON 08 71 00 Page 10

Addendum #1 - 08/21/2024

Estrada, Oscar A.

Cloud

2. 3. 14 Cl oser s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 4, Ser i es C02000, Gr ade 1, wi t h PT 4C. Pr ovi de wi t h br acket s, ar ms, mount i ng devi ces, f ast ener s, f ul l s i ze cover s, except at st or ef r ont mount i ng, and ot her f eat ur es necessar y f or t he par t i cul ar appl i cat i on. Si ze c l oser s i n accor dance wi t h manuf act ur er ' s pr i nt ed r ecommendat i ons, or pr ovi de mul t i - s i ze c l oser s, Si zes 1 t hr ough 6, and l i s t s i zes i n t he Har dwar e Schedul e. Pr ovi de manuf act ur er ' s 10 year war r ant y.

Use st ai nl ess st eel i nsi de br acket ed or door mount ed cl oser s on ext er i or door s. Non- f er r ous cl oser s, such as al umi num or cast br onze, ar e per mi ssi bl e wher e door ut i l i zat i on i s mi ni mal . On i nt er i or door s use cl oser s of 302 or 304 st ai nl ess st eel or non- f er r ous mat er i al s. On sur f ace- mount ed cl oser s use or appl y r ust i nhi bi t i ng f i ni sh on al l f er r ous par t s. Al so appl y t hi s f i ni sh on conceal ed cl oser s.

2. 3. 14. 1 I dent i f i cat i on Mar ki ng

Engr ave each cl oser wi t h manuf act ur er ' s name or t r ademar k, dat e of manuf act ur e, and manuf act ur er ' s s i ze desi gnat i on i n l ocat i ons t hat wi l l be v i s i bl e af t er i nst al l at i on.

2. 3. 15 Over head Hol der s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 8.

2. 3. 16 Door Pr ot ect i on Pl at es

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 6.

2. 3. 16. 1 Si zes of Ki ck Pl at es

2 i nch l ess t han door wi dt h f or s i ngl e door s; 1 i nch l ess t han door wi dt h f or pai r s of door s. Pr ovi de 10 i nch ki ck pl at es f or f l ush door s .

Pr ovi de a mi ni mum 36 i nch ar mor pl at es f or f l ush door s and compl et el y cover l ower panel s of panel door s, except 16 i nch hi gh ar mor pl at es on f i r e door s. Pr ovi de 6 i nch mop pl at es.

2. 3. 16. 2 Edge Guar ds

St ai nl ess st eel , of same hei ght as ar mor pl at es.

2. 3. 17 Door St ops and Si l encer s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16. Si l encer s Type L03011.

Pr ovi de t hr ee si l encer s f or each si ngl e door , t wo f or each pai r .

2. 3. 18 Padl ocks

Pr ovi de i n accor dance wi t h ASTM F883.

2. 3. 19 Thr eshol ds

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 21. Use J35100, wi t h v i nyl or s i l i cone r ubber i nser t i n f ace of st op, f or ext er i or door s openi ng out , unl ess speci f i ed ot her wi se.

SECTI ON 08 71 00 Page 11

2. 3. 20 Weat her st r i ppi ng Gasket i ng

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de t he t ype and f unct i on desi gnat i on wher e speci f i ed i n par agr aph HARDWARE SCHEDULE.

Pr ovi de a set t o i ncl ude head and j amb seal s, sweep st r i ps, and, f or pai r s of door s, ast r agal s. Ai r l eakage of weat her st r i pped door s not t o exceed

1. 25 cubi c f eet per mi nut e of ai r per squar e f oot of door ar ea when t est ed i n accor dance wi t h ASTM E283. Pr ovi de weat her st r i ppi ng wi t h one of t he f ol l owi ng:

2. 3. 20. 1 Ext r uded Al umi num Ret ai ner s

Ext r uded al umi num r et ai ner s not l ess t han 0. 050 i nch wal l t hi ckness wi t h v i nyl , neopr ene, s i l i cone r ubber , or pol yur et hane i nser t s. Pr ovi de cl ear ( nat ur al ) anodi zed al umi num.

2. 3. 20. 2 I nt er l ocki ng Type

Zi nc or br onze not l ess t han 0. 018 i nch t hi ck.

2. 3. 20. 3 Spr i ng Tensi on Type

Spr i ng br onze or st ai nl ess st eel not l ess t han 0. 008 i nch t hi ck.

2. 3. 21 Gasket i ng

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de adj ust abl e door st ops at heads, j ambs and aut omat i c door bot t oms i n accor dance wi t h t he har dwar e set , of ext r uded al umi num, c l ear ( nat ur al ) anodi zed, sur f ace appl i ed, wi t h v i nyl f i n seal s bet ween pl unger and housi ng. Pr ovi de door st ops wi t h sol i d neopr ene t ube, s i l i cone r ubber , or c l osed cel l sponge gasket . Pr ovi de door bot t oms wi t h adj ust abl e oper at i ng r od and si l i cone r ubber or c l osed cel l sponge neopr ene gasket . Pr ovi de door st ops t hat ar e mi t er ed at cor ner s. Pr ovi de t ype and f unct i on desi gnat i on wher e speci f i ed i n par agr aph HARDWARE SETS.

2. 3. 22 Rai n Dr i ps

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de ext r uded al umi num r ai n dr i ps, not l ess t han 0. 08 i nch t hi ck, c l ear anodi zed f i ni sh. Pr ovi de t he manuf act ur er ' s f ul l r ange of col or choi ces t o t he Cont r act i ng Of f i cer f or col or sel ect i on. Pr ovi de r ai n dr i ps wi t h a 4 i nch over l ap on each si de of each ext er i or door t hat i s not pr ot ect ed by an awni ng, r oof , eave or ot her hor i zont al pr oj ect i on. Set dr i ps i n seal ant and f ast en wi t h st ai nl ess st eel scr ews.

2. 3. 22. 1 Door Rai n Dr i ps

Appr oxi mat el y 1- 1/ 2 i nch hi gh by 5/ 8 i nch pr oj ect i on. Al i gn bot t om wi t h bot t om edge of door .

2. 3. 22. 2 Over head Rai n Dr i ps

Appr oxi mat el y 1- 1/ 2 i nch hi gh by 2- 1/ 2 i nch pr oj ect i on. Al i gn bot t om wi t h door f r ame r abbet .

2. 3. 23 Auxi l i ar y Har dwar e ( Ot her t han l ocks)

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16, Gr ade 1.

SECTI ON 08 71 00 Page 12

2. 3. 24 Sl i di ng and Fol di ng Door Har dwar e

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 14, Gr ade 1. Fi ni shes t o mat ch ot her har dwar e speci f i ed her ei n.

2. 3. 25 Speci al Tool s

Pr ovi de speci al t ool s, such as spanner and socket wr enches and doggi ng keys, as r equi r ed t o ser vi ce and adj ust har dwar e i t ems.

2. 4 FASTENERS

Pr ovi de f ast ener s of t ype, qual i t y, s i ze, and quant i t y appr opr i at e t o t he speci f i c appl i cat i on. Fast ener f i ni sh t o mat ch har dwar e. Pr ovi de st ai nl ess st eel or nonf er r ous met al f ast ener s i n l ocat i ons exposed t o weat her . Ver i f y met al s i n cont act wi t h one anot her ar e compat i bl e and wi l l avoi d gal vani c cor r osi on when exposed t o weat her .

2. 5 FI NI SHES

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 18. Pr ovi de har dwar e i n BHMA 630 f i ni sh ( sat i n st ai nl ess st eel ) , unl ess speci f i ed ot her wi se. Pr ovi de i t ems not manuf act ur ed i n st ai nl ess st eel i n BHMA 626 f i ni sh ( sat i n chr omi um pl at ed) over br ass or br onze, except al umi num pai nt pr i me coat f i ni sh f or sur f ace door c l oser s, and except BHMA 600 f i ni sh ( pr i med f or pai nt i ng) f or st eel hi nges. Pr ovi de hi nges f or ext er i or door s i n st ai nl ess st eel wi t h BHMA 630 f i ni sh or chr omi um pl at ed br ass or br onze wi t h BHMA 626 f i ni sh. Fur ni sh exi t devi ces i n BHMA 626 f i ni sh i n l i eu of BHMA 630 f i ni sh except wher e BHMA 630 i s speci f i ed under par agr aph HARDWARE SETS. Mat ch exposed par t s of conceal ed cl oser s t o l ock and door t r i m. Mat ch har dwar e f i ni sh f or al umi num door s t o t he door s.

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 18. Pr ovi de har dwar e i n BHMA 612 f i ni sh ( sat i n br onze) , unl ess speci f i ed ot her wi se. Fi ni sh sur f ace door c l oser s pr i me coat f i ni sh. Pr ovi de st eel hi nges i n BHMA 600 f i ni sh ( pr i med f or pai nt i ng) . Pr ovi de exposed par t s of conceal ed cl oser s f i ni sh t o mat ch l ock and door t r i m. Mat ch har dwar e f i ni sh f or al umi num door s t o mat ch t he door s. Pr ovi de har dwar e showi ng on i nt er i or of bat hr ooms shower r ooms t oi l et r ooms and ki t chens i n BHMA 629 f i ni sh ( br i ght st ai nl ess st eel ) or BHMA 625 f i ni sh ( br i ght chr omi um pl at ed) .

2. 6 KEY CABI NET AND CONTROL SYSTEM

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5, Type r equi r ed t o y i el d a capaci t y ( number of hooks) 50 per cent gr eat er t han t he number of key changes used f or door l ocks.

PART 3 EXECUTI ON

3. 1 I NSTALLATI ON

Pr ovi de har dwar e i n accor dance wi t h manuf act ur er s ' pr i nt ed i nst al l at i on i nst r uct i ons. Fast en har dwar e t o wood sur f aces wi t h f ul l - t hr eaded wood scr ews or sheet met al scr ews. Pr ovi de machi ne scr ews set i n expansi on shi el ds f or f ast eni ng har dwar e t o sol i d concr et e and masonr y sur f aces.

Pr ovi de t oggl e bol t s wher e r equi r ed f or f ast eni ng t o hol l ow cor e const r uct i on. Pr ovi de t hr ough bol t s wher e necessar y f or sat i sf act or y i nst al l at i on.

SECTI ON 08 71 00 Page 13

3. 1. 1 Weat her st r i ppi ng I nst al l at i on

Pr ovi de f ul l cont act , weat her t i ght seal s t hat al l ow oper at i on of door s wi t hout bi ndi ng t he weat her st r i ppi ng.

3. 1. 1. 1 St op Appl i ed Weat her st r i ppi ng

Fast en i n pl ace wi t h col or mat ched sheet met al scr ews not mor e t han 9 i nch on cent er af t er door s and f r ames have been f i ni sh pai nt ed.

3. 1. 1. 2 I nt er l ocki ng Type Weat her st r i ppi ng

Pr ovi de i nt er l ocki ng, sel f adj ust i ng t ype on heads and j ambs and f l exi bl e hook t ype at s i l l s . Nai l weat her st r i ppi ng t o door 1 i nch on cent er and t o heads and j ambs at 4 i nch on cent er .

3. 1. 1. 3 Spr i ng Tensi on Type Weat her st r i ppi ng

Pr ovi de spr i ng t ensi on t ype on heads and j ambs. Pr ovi de br onze nai l s wi t h br onze. Pr ovi de st ai nl ess st eel nai l s wi t h st ai nl ess st eel . Space nai l s not mor e t han 1- 1/ 2 i nch on cent er .

3. 1. 2 I nst al l at i on

Pr ovi de as speci f i ed f or st op appl i ed weat her st r i ppi ng.

3. 1. 3 Thr eshol d I nst al l at i on

Ext end t hr eshol ds t he f ul l wi dt h of t he openi ng and not ch end f or j amb st ops. Set t hr eshol ds i n a f ul l bed of seal ant and anchor t o f l oor wi t h cadmi um- pl at ed, count er sunk, st eel scr ews i n expansi on sl eeves. For al umi num t hr eshol ds pl aced on t op of concr et e sur f aces, coat t he under si de sur f aces t hat ar e i n cont act wi t h t he concr et e wi t h f l ui d appl i ed wat er pr oof i ng as a separ at i on measur e pr i or t o pl acement .

3. 2 FI RE DOORS AND EXI T DOORS

Pr ovi de har dwar e i n accor dance wi t h NFPA 72 f or door al ar ms, NFPA 80 f or f i r e door s, NFPA 101 f or exi t door s, and NFPA 252 f or f i r e t est s of door assembl i es. .

3. 3 HARDWARE LOCATI ONS

Pr ovi de i n accor dance wi t h SDI / DOOR A250. 8, unl ess i ndi cat ed or speci f i ed ot her wi se.

a. Ki ck and Ar mor Pl at es: Push si de of s i ngl e- act i ng door s. Bot h s i des of doubl e- act i ng door s.

b. Mop Pl at es: Bot t om f l ush wi t h bot t om of door .

3. 4 KEY CABI NET AND CONTROL SYSTEM

Locat e wher e di r ect ed. Tag one set of f i l e keys and one set of dupl i cat e keys. Pl ace ot her keys i n appr opr i at el y mar ked envel opes, or t ag each key. Pr ovi de compl et e i nst r uct i ons f or set up and use of key cont r ol syst em. On t ags and envel opes, i ndi cat e door and r oom number s or mast er or gr and mast er key.

SECTI ON 08 71 00 Page 14

3. 5 FI ELD QUALI TY CONTROL

Af t er i nst al l at i on, pr ot ect har dwar e f r om pai nt , st ai ns, bl emi shes, and ot her damage unt i l accept ance of wor k. Submi t not i ce of t est i ng 15 days bef or e schedul ed, so t hat t est i ng can be wi t nessed by t he Cont r act i ng Of f i cer . Adj ust hi nges, l ocks, l at ches, bol t s, hol der s, c l oser s, and ot her i t ems t o oper at e pr oper l y. Demonst r at e t hat per manent keys oper at e r espect i ve l ocks, and gi ve keys t o t he Cont r act i ng Of f i cer . Cor r ect , r epai r , and f i ni sh, er r or s i n cut t i ng and f i t t i ng and damage t o adj oi ni ng wor k.

3. 6 HARDWARE SETS

SECTI ON 08 71 00 Page 15

SET 1. 0 ( ENTRANCE DOOR - DOUBLE EXTERI OR)

DOOR: 101A

6 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

2 EXI T DEVI CE, FUNCTI ON 10

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 KEYED REMOVABLE MULLI ON

2 SURFACE CLOSER

2 GASKETI NG/ WEATHER STRI PPI NG

2 RAI N GUARD

2 SWEEP W/ HOOD

1 THRESHOLD

OPERATI ON:

1. ENTRANCE EXTERI OR LEVER. I NSI DE KEY LOCKS/ UNLOCKS EXTERI OR LEVER.

OUTSI DE KEY ONLY RETRACTS LATCH.

2. I NSI DE EXI T DEVI CE I S ALWAYS FREE FOR I MMEDI ATE EGRESS

3. I F THUMBTURN OR DEADBOLT I S ADDED, SI GNAGE MUST BE POSTED THAT READS

" THI S DOOR TO REMAI N UNLOCKED WHI LE BUI LDI NG I S OCCUPI ED, " AND BE

APPROVED BY LOCAL AHJ.

SET 2. 0 ( ENTRANCE DOOR - DOUBLE I NTERI OR)

DOOR: 101B

6 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

2 EXI T DEVI CE, FUNCTI ON 10

1 KEYED REMOVABLE MULLI ON

2 SURFACE CLOSER

2 GASKETI NG/ WEATHER STRI PPI NG

2 RAI N GUARD

2 SWEEP W/ HOOD

1 THRESHOLD

OPERATI ON:

1. ENTRANCE EXTERI OR LEVER. I NSI DE KEY LOCKS/ UNLOCKS EXTERI OR LEVER.

OUTSI DE KEY ONLY RETRACTS LATCH.

2. I NSI DE EXI T DEVI CE I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 3. 0 ( STOREROOM DOOR - SI NGLE EXTERI OR)

DOOR: 119B, 120C

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 EXI T DEVI CE, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG/ WEATHER STRI PPI NG

1 RAI N GUARD

1 SWEEP W/ HOOD

1 THRESHOLD

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SECTI ON 08 71 00 Page 16

SET 4. 0 ( STOREROOM DOOR - DOUBLE EXTERI OR)

DOOR: 121, 122, 123

6 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 EXI T DEVI CE, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH

( ACTI VE LEAF)

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 MORTI SE STI KE ( I NACTI VE LEAF)

1 ASTRAGAL

2 FLUSH BOLTS ( I NACTI VE LEAF)

2 SURFACE CLOSER

2 WALL / FLOOR STOP

2 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE ACTI VE LEAF.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

4. I NACTI VE LEAF I S HELD I N PLACE BY SURFACE MOUNTED FLUSH BOLTS TOP AND

BOTTOM AND CAN BE RETRACTED FROM I NSI DE FACE ONLY.

SET 5. 0 ( EXI T ONLY - SI NGLE EXTERI OR)

DOOR: 108, 118A, 118B, 118C, 118D

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 EXI T DEVI CE, ( NO EXTERI OR HARDWARE)

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. NO EXTERI OR HARDWARE.

2. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SET 6. 0 ( OVERHEAD - EXTERI OR)

DOOR: 119A

2 HI GH SECURI TY SWI TCH

SEE 08 36 13 SECTI ONAL OVERHEAD DOORS FOR DOOR HARDWARE REQUI REMENTS.

NOTES:

1. HI GH SECURI TY SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO THE I NTRUSI ON

DETECTI ON SYSTEM. PLACE SWI TCHES ON THE LEFT AND RI GHT SI DE OF DOOR

FRAME AT FLOOR LEVEL ON SECURE SI DE OF DOOR.

SET 7. 0 ( OFFI CE DOOR - SI NGLE I NTERI OR)

DOOR: 103, 104

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 OFFI CE, MORTI SE LOCKSET, FUNCTI ON 04

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. LATCHBOLT RETRACTED BY LEVER FROM EI THER SI DE UNLESS OUTSI DE I S MADE

SECTI ON 08 71 00 Page 17

I NOPERATI VE BY KEY OUTSI DE OR I NSI DE PUSHBUTTON.

2. WHEN OUTSI DE I S LOCKED, THE LATCHBOLT I S RETRACTED BY KEY OUTSI DE OR BY

LEVER I NSI DE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 8. 0 ( STOREROOM DOOR - SI NGLE I NTERI OR)

DOOR: 106, 110

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 STOREROOM, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SET 9. 0 ( PUSH/ PULL DOOR - SI NGLE I NTERI OR)

DOOR: 112, 115

3 HI NGE ( SI ZE PER SPEC)

1 PULL PLATE

1 PUSH PLACE

1 SURFACE CLOSER

1 KI CK PLATE

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. NO LATCHI NG I S REQUI RED. PUSH / PULL PLATE.

SET 10. 0 ( PASSAGE DOOR - SI NGLE I NTERI OR)

DOOR: 113, 116, 114A, 114C, 117A

3 HI NGE ( SI ZE PER SPEC)

1 PASSAGE, MORTI SE LOCKSET, FUNCTI ON 01

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. LATCHBOLT RETRACTED BY LEVER FROM EI THER SI DE AT ALL TI MES.

2. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SET 11. 0 ( ACCESS CONTROL DOOR - SI NGLE I NTERI OR)

DOOR: 114B, 117B, 119C, 120A

1 CONTI NUOUS HI NGE

1 STOREROOM- FAI L SECURE LOCK, FUNCTI ON 07, MORTI SE LOCKSET, ELECTRI C LATCH

RETRACTI ON, FI XED EXTERI OR LEVER HANDLE, KEY OVERRI DE, FAI L SECURE,

( WI TH ESS I NTEGRATI ON)

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 ELECTRI C TRANSFER DEVI CE

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG SMOKE/ SOUND

SECTI ON 08 71 00 Page 18

1 CARD READER / KEYPAD

1 POWER SUPPLY VOLTAGE X AMPERAGE AS REQ' D

OPERATI ON:

1. CARD READER / KEYPAD GRANTS ACCESS UPON PRESENTATI ON OF A VALI D

CREDENTI AL TO SI GNAL ELECTRI C LATCH RETRACTI ON.

2. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE HANDLE ON

RESTRI CTED SI DE.

3. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

4. REQUEST SWI TCH I NSI DE HANDLE TO SI GNAL AUTHORI ZED EGRESS TO THE ACCESS

CONTROL SYSTEM. BALANCED MAGNETI C SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO

THE I NTRUSI ON DETECTI ON SYSTEM.

5. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 12. 0 ( OVERHEAD - I NTERI OR)

DOOR: 120B

2 HI GH SECURI TY SWI TCH

SEE 08 36 13 SECTI ONAL OVERHEAD DOORS FOR DOOR HARDWARE REQUI REMENTS.

NOTES:

1. HI GH SECURI TY SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO THE I NTRUSI ON

DETECTI ON SYSTEM. PLACE SWI TCHES ON THE LEFT AND RI GHT SI DE OF DOOR

FRAME AT FLOOR LEVEL ON SECURE SI DE OF DOOR.

- - End of Sect i on - -

SECTI ON 08 71 00 Page 19

08 71 00 - DOOR HARDWARE
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SHOP DRAWINGS
1.4 PRODUCT DATA
1.5 HARDWARE SCHEDULE
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
1.7.2 Key Shop Drawings Coordination Meeting

1.8 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
2.3 HARDWARE ITEMS
2.3.1 Hinges
2.3.1.1 Maximum Security Pin MSP
2.3.1.2 Non-Removeable Pin NRP
2.3.2 Continuous Hinges
2.3.3 Spring Hinges
2.3.4 Locks and Latches
2.3.4.1 Auxiliary Locks
2.3.4.2 5-Button Mechanical Locksets
2.3.4.3 Bored Locks and Latches
2.3.4.4 Mortise Locks and Latches
2.3.5 Exit Devices
2.3.5.1 Electric Exit Devices
2.3.6 Exit Locks With Alarm
2.3.7 Cylinders and Cores
2.3.7.1 High
2.3.8 Push Button Mechanisms
2.3.9 Electrified Hardware
2.3.9.1 Electric Strikes and Frame Mounted Actuators
2.3.9.1.1 Solenoid
2.3.9.1.2 Signal Switches
2.3.9.1.3 Tamper Resistance
2.3.9.1.4 Coordination
2.3.9.1.5 Mounting Method
2.3.9.2 Electrified Mortise Locks
2.3.9.2.1 Power Transfer Hinges
2.3.9.3 Card Readers and Keypad Access Control Hardware
2.3.9.4 Power Operated Pedestrian Door Hardware
2.3.9.5 Release Devices
2.3.9.5.1 Closer Holders
2.3.9.5.2 Release Devices
2.3.9.6 Electromagnetic Locks
2.3.9.6.1 Armature
2.3.9.6.2 Tamper Resistance
2.3.9.6.3 Mounting Method

2.3.9.7 Delayed Egress Locking System

2.3.10 Keying System
2.3.11 Lock Trim
2.3.11.1 Knobs and Roses
2.3.11.2 Lever Handles
2.3.12 Keys
2.3.13 Door Bolts
2.3.14 Closers
2.3.14.1 Identification Marking
2.3.15 Overhead Holders
2.3.16 Door Protection Plates
2.3.16.1 Sizes of Kick Plates
2.3.16.2 Edge Guards
2.3.17 Door Stops and Silencers
2.3.18 Padlocks
2.3.19 Thresholds
2.3.20 Weatherstripping Gasketing
2.3.20.1 Extruded Aluminum Retainers
2.3.20.2 Interlocking Type
2.3.20.3 Spring Tension Type
2.3.21 Gasketing
2.3.22 Rain Drips
2.3.22.1 Door Rain Drips
2.3.22.2 Overhead Rain Drips
2.3.23 Auxiliary Hardware Other than locks
2.3.24 Sliding and Folding Door Hardware
2.3.25 Special Tools
2.4 FASTENERS
2.5 FINISHES
2.6 KEY CABINET AND CONTROL SYSTEM
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Weatherstripping Installation
3.1.1.1 Stop Applied Weatherstripping
3.1.1.2 Interlocking Type Weatherstripping
3.1.1.3 Spring Tension Type Weatherstripping
3.1.2 Installation
3.1.3 Threshold Installation
3.2 FIRE DOORS AND EXIT DOORS
3.3 HARDWARE LOCATIONS
3.4 KEY CABINET AND CONTROL SYSTEM
3.5 FIELD QUALITY CONTROL
3.6 HARDWARE SETS