Addendum 3 - A-103-ROOF PLAN.pdf
PDF 328 KB Posted
- Attached to
- Construct Corrosion Control Facility Federal contract opportunity
- Solicitation number
- W50S78-24-B-0002
- Issued by
- Department of the Army National Guard
About this file
This document is an Addendum 3 to the construction plans for a new 12,200 square foot Corrosion Control Facility for the Texas Air National Guard at Joint Base San Antonio - Kelly Field Annex. The facility will include an environmentally controlled aircraft wash area, hangar space for corrosion treatment and repair, paint preparation and drying areas, abrasive blasting rooms, and administrative spaces. The solicitation includes a base bid and four options: translucent fiberglass panels, screen wall, alternate standing seam metal roofing, and epoxy flooring. Four brand name items are specified for the fire alarm, HVAC, door locks, and building automation system. The project is set aside for small businesses under NAICS code 236220, with an estimated construction value of $10-25 million. A site visit and pre-bid conference are scheduled, and questions are due 5 days prior to bid opening. The contract duration is 540 calendar days.
View the file
Other files for this federal contract opportunity
Show all 49
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A A
B B
C C
E E
A-301 A3
A-301 A3
B3 A-202
A6 A-201
A3 A-201
A6 A-202
A-301
B6
A-301 B6
A-303 D6
A-302 B6
A-302 D6
D D
2" / 1'-0" 2" / 1'-0"2" / 1'-0"
2" / 1'-0"
ADMIN.
SUPPORT
HANGAR
GABLE
HANGAR DOOR POCKET
MONO/SHED
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
20190320
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
TX
AN
G Pr oj ec t N um be r:
KE
LL
JB
SA
Ke lly A nn ex , T X
Te xa s Ai r N at io na l G ua rd 9t h
FW
Co rro sio n Co nt ro l F ac ilit y
NDM
A
B C D
A B C D
E F G H
E F G
H I
I
C :\U sers\oae\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_O
Estrada6SZ64.rvt
9/9/2024 11:57:40 AM
2 AUGUST 2024
A-103
ROOF PLAN
BKG
JCL
JCL
SCALE: 1/8" = 1'-0"
ROOF PLANA6
SHEET KEYNOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
PRE-FINISHED STANDING SEAM METAL ROOF
(SSMR1).
PRE-FINISHED METAL GUTTER, 8"X8".
PRE-FINISHED EAVE TRIM.
PRE-FINISHED RIDGE FLASHING.
28" DIA. PAINT BOOTH EXHAUST.
EXPANSON JOINT.
PRE-MANUFACTURED METAL SUN SHADE SYSTEM.
LIGHTNING PROTECTION, RE: ELECTRICAL.
FALL ARREST SYSTEM, RE: B2/A-502 (TAILOR TO
FINAL ROOF MATERIAL STANDING SEAM AND OR R-
PANEL)
EXHAUST PIPE, RE: G4/A-502.
VENT PIPE, RE: F2/A-502.
HOODED GRAVITY ROOF EXHAUST WITH PRE-
FABRICATED CURB AND INTEGRAL CRICKET, RE:
A5/A-502.
12" DIA. EXHAUST VENT.
12" DIA. EXHAUST AIR VENT.
6" DIA. EXHAUST AIR VENT.
PRE-FINISHED STANDING SEAM METAL ROOF
(SSMR1)- BID OPTION NO.3 AT HANGAR.
METAL ROOFING R-PANEL- BASE BID AT HANGAR.
0 4' 8' 16'
1/8" = 1'-0"
N
0 ADDENDUM 03 09/09/2024