About this file
This document appears to be Addendum 3 to the construction drawings for a Corrosion Control Facility project for the Texas Air National Guard at Joint Base San Antonio - Kelly Field Annex. The overall federal contract opportunity is for the construction of a new 12,200 square foot Corrosion Control Facility, including an environmentally controlled aircraft wash area, hangar space for corrosion treatment and repair, administrative spaces, and 1,500 square yards of airfield pavements. The contract will be a single firm fixed-price award with a 540 calendar day performance period. The solicitation includes a base bid and four options, as well as several brand name items required for compatibility with existing systems. This opportunity is set aside 100% for Small Businesses under NAICS code 236220, with an estimated contract value between $10-25 million. A site visit and pre-bid conference are scheduled, and all questions must be submitted by a specified deadline prior to bid opening.
View the file
Other files for this federal contract opportunity
Show all 49
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5/8" GWB
CONC. FLOOR SLAB
6" CFMF @ 16" O.C.
BRICK
RIGID INSULATION (AIR
BARRIER R-15 MIN)
FLUID APPLIED AIR
BARRIER
MORTAR CONTROL
MESH
WEEP HOLES
AT 24" OC WITH
MEMBRANE
THROUGH
FLASHING
GROUT FILL
BATT INSULATION
SUPPORT EAVE
HEIGHT
115' - 0"
2" / 1'-0"
STRUCTURAL STEEL
ROOF INSULATION
LINER SYSTEM
(R-35 MIN.)
2" INSULATED METAL
WALL PANEL (FWP1)
R-15 MIN WALL
SYSTEM
PRE-FINISHED
METAL
GUTTER AND
DOWNSPOUT
STRUCTURAL STANDING
SEAM METAL ROOF
(SSMR1) - BID OPTION NO.3
PURLINS
GIRTS
3 4
8" CMU
SPRAY FOAM SEALANT
(R-35 MIN.)
STRUCTURAL STEEL
VAPOR BARRIER
LINER FABRIC
PRE-FINISHED METAL
DOWNSPOUT
STRUCTURAL
STANDING SEAM
METAL ROOF (SSMR1) -
BID OPTION NO.3
UNFACED INSULATION
WALL LINER SYSTEM
(R-15 MIN.)
ROOF INSULATION
LINER SYSTEM
(R-35 MIN.)
GIRTS
PREMANUFACTURED
WALL PANEL (MWP1)
CONT PREFIN SHEET METAL
J FLASHING
2" EXPANSION JOINT
CONT PREFIN SHEET
METAL SLIP JOINT
FLASHING WITH
TERMINATION BAR
CONT SELF-ADHERED
UNDERLAYMENT CLOSURE
HANGAR EAVE HEIGHT
140' - 0"
2" / 1'-0"
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUT
STRUCTURAL STANDING
SEAM METAL ROOF
(SSMR1) - BID OPTION NO.3
FIBERGLASS SANDWICH
PANEL ASSEMBLY- BID
OPTION NO.1
STRUCTURAL STEEL
ROOF INSULATION
LINER SYSTEM (R-35 MIN.)
2" INSULATED METAL
WALL PANEL (FWP1)
R-15 MIN. WALL SYSTEM
PURLINS
C4 A-501
C6 A-501
5/8" GWB
PRE-FINISHED METAL
FLASHING
6" CFMF @ 16" O.C.
BRICK
RIGID INSULATION
(AIR BARRIER R-15
MIN)
2" INSULATED METAL
WALL PANEL (FWP1)
R-15 MIN WALL SYSTEM
GIRTS
6" CFMF INFILL
@ 16" O.C.
2" MIN. SPRAYED
POLYURETHANE
FOAM INSULATION
R-15 MIN
FLUID APPLIED AIR
BARRIER
BATT INSULATION
HANGAR EAVE HEIGHT
140' - 0"
FIBERGLASS SANDWICH
PANEL ASSEMBLY- BID
OPTION NO.1
PRE-FINISHED METAL
GUTTER AND DOWN-
SPOUT
2" INSULATED METAL
WALL PANEL (FWP1)
R-15 MIN. WALL SYSTEM
2" / 1'-0"
STRUCTURAL STANDING
SEAM METAL ROOF
(SSMR1)
C3 A-501
ROOF INSULATION
LINER SYSTEM (R-35 MIN.)
(SSMR1) PREFIN
RIDGE CLOSURE AND
ZEE FLASHING
ROOF INSULATION
LINER SYSTEM (R-35 MIN.)
PEMB STRUCTRAL
FRAME
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
20190320
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
TX
AN
G Pr oj ec t N um be r:
KE
LL
JB
SA
Ke lly A nn ex , T X
Te xa s Ai r N at io na l G ua rd 9t h
FW
Co rro sio n Co nt ro l F ac ilit y
NDM
A
B C D
A B C D
E F G H
E F G
H I
I
C :\U sers\oae\O neD rive - FSB Architects + Engineers\D ocum ents\90320_Arch_O
Estrada6SZ64.rvt
9/9/2024 11:57:46 AM
2 AUGUST 2024
A-500
DETAILS
BKG
JCL
JCL
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA6
SCALE: 1 1/2" = 1'-0"
SECTION DETAILA2
SCALE: 1 1/2" = 1'-0"
SECTION DETAILC6
SCALE: 1 1/2" = 1'-0"
SECTION DETAILD4SCALE: 1 1/2" = 1'-0"
SECTION DETAILA4
SCALE: 1 1/2" = 1'-0"
SECTION DETAILF5
6" 1'-6"1'0
1 1/2" = 1'-0"
SCALE: 1 1/2" = 1'-0"
SECTION DETAILG6
0 ADDENDUM 03 09/09/2024