Typical-Edge-Flashing-Model.pdf
PDF 136 KB Posted
- Attached to
- High School Roof Replacement
- Solicitation number
- RFP MASO 260000002613 2
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical specification drawing for typical edge flashing installation details, provided as reference material for a construction or roofing project. The document outlines the standard configuration for edge flashing using Tremco Metal products and Tremply Kee membrane systems. The specification details the fastening requirements, including galvanized annular ring shank nails installed at 6-inch on-center spacing, wood blocking attached at 250 pounds-force per foot continuous, and metal cleats secured with ring shank nails at 3-inch on-center spacing. The flashing strip is 4 inches minimum in width and is heat-welded in place, with a 1/4-inch gap specification and aluminum tape measuring 4 inches wide applied across the joint. Additional components include butyl sealing tape (optional), insulation attached per specification requirements, and joint treatment at the metal edge.
This drawing serves as a standard detail for bidders and contractors to reference when preparing proposals and executing work related to roof or building edge flashing installation. No specific pricing, contract term, bid deadline, or project award information is provided in this technical specification document. The drawing is identified as Drawing Number 114 and is drawn to a not-to-scale standard, dated 2023. Contractors should use this typical detail as a baseline for material selection, installation methodology, and cost estimation for projects requiring edge flashing work consistent with these specifications.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TREMCO METAL
TREMPLY KEE MEMBRANE FLASHING STRIP
TREMPLY KEE MEMBRANE
GALVANIZED ANNULAR RING
SHANK NAILS (6" O.C.)
HOT AIR WELD
INSULATION ATTACHED PER
SPECIFICATION REQUIREMENTS
WOOD BLOCKING
ATTACHED @ 250 LBF/FT
CONTINUOUS GALVANIZED METAL CLEAT
BUTYL SEALING TAPE (OPTIONAL)
RING SHANK NAILS (3" O.C.)
FASTEN WITH GALVANIZED ANNULAR
JOINT TREATMENT AT EDGE METAL
4" MIN.
1/4" 2"
4"
TREMCO METAL
2" WIDE
OVER JOINT
1/4" GAP
ALUMINUM TAPE
4" WIDE FLASHING STRIP,
HEAT WELDED IN PLACE
TREMPLY KEE MEMBRANE EDGE FLASHING STRIP
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
TYPICAL EDGE FLASHING
DWG NO. 114
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .