Gauge-or-Thickness-Guide.pdf

PDF 108 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 2
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a metal finish gauge and thickness guide specification document that establishes minimum material standards for construction work. The document specifies gauge requirements for galvanized iron, aluminum, cold rolled steel, and copper materials used in coping caps, flashing, and fascia applications. The specifications are differentiated based on exposed face dimensions, ranging from faces up to 6 inches to faces of 10 to 15 inches. Galvanized iron requirements range from 20 gauge for the largest faces to 24 gauge for smaller applications. Aluminum thickness specifications range from 0.080 inches (12 gauge equivalent) for larger faces down to 0.040 inches (18 gauge equivalent) for smaller faces. Cold rolled steel coping cap flashing is specified at 20 ounces for the largest faces and 16 ounces for smaller applications. The document notes that brakes should be added to stiffen materials where applicable.

No pricing information, contract award dates, bidding timelines, or project cost details are provided in this specification document. This appears to be a technical reference guide intended to establish material quality and durability standards for metal components rather than a standalone procurement document containing commercial terms or solicitation parameters.

View the file

Other files

File Type Posted
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 13

METAL FINISH

GAUGE OR THICKNESS GUIDE (MINIMUM)

GALVANIZED IRON

10'' TO 15'' FACE

8'' TO 10'' FACE

UP TO 6'' FACE

6'' TO 8'' FACE

WITHOUT BRAKES

''A'' DIMENSIONS

EXPOSED FACE

20 GA.

22 GA.

24 GA.

24 GA.

ALUMINUM

.080'' (12 GA.)

.064'' (14 GA.)

.050'' (16 GA.)

.040'' (18 GA.)

ADD BRAKES

TO STIFFEN

COLD ROLLED

20 OZ.

16 OZ.

16 OZ.

COPING CAP FLASHING VARIATIONS

AND FASCIA

COPPER 3003-H14

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text A

AutoCAD SHX Text A