This is a technical specification document for Tremco Low Rise Foam Insulation Adhesive application procedures, though no specific contracting agency or jurisdiction is identified in the file. The document provides detailed installation guidelines for adhesive application on roofing projects, specifying that insulation boards must be placed into the adhesive within 15 seconds of application and stepped into place without repositioning once set. The specification requires adhesive application at 12 inches on center in the field of the roof (four beads per board), 6 inches on center in perimeter areas (eight beads per board), and 4 inches on center in corner areas (twelve beads per board). No quantities, response dates, due dates, site visits, bidders meetings, award dates, or contract terms are specified in this document.
The document does not include pricing terms, set asides, incumbent information, funding requirements or sources, or other contract-specific details. The specification indicates that ideal ambient temperature for application should be 45 degrees Fahrenheit and rising, with material temperature maintained between 70 and 85 degrees Fahrenheit. The document is dated 2023 and references Drawing No. TLRFIA-002, suggesting it is part of a larger technical specification set, but no additional contractual or budgetary information is provided.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
TLRFIA-002
TREMCO LOW RISE FOAM
INSULATION ADHESIVE
NOTE:
1. INSULATION BOARDS MUST BE PLACED INTO THE ADHESIVE AS SOON AS IT STARTS TO FOAM (WITHIN 15 SECONDS). STEP BOARDS
INTO PLACE. DO NOT REPOSITION BOARDS ONCE THEY ARE SET. DO NOT PUDDLE OR MOUND THE ADHESIVE AS THIS CAN LEAD TO
EXCESSIVE RISE AND BOARD SURFACE UNEVENNESS.
2. IDEAL AMBIENT TEMPERATURE FOR APPLICATION IS 45F AND RISING. MATERIAL TEMPERATURE MUST BE BETWEEN 70F AND 85F.
3. APPLY ADHESIVE AT 12" O.C. AT THE FIELD OF THE ROOF (4 BEADS PER BOARD).
4. APPLY ADHESIVE AT 6" O.C. IN PERIMETER AREAS (8 BEADS PER BOARD) AND 4" O.C IN CORNER AREAS (12 BEADS PER BOARD).
| Sheets and Views |