About this file

This is a technical drawing specification document for built-up roof hot/cold wall flashing for non-wall-supported deck construction. The drawing (DWG No. 11) details the installation requirements for a specified Bureau of Roofing (BUR) membrane system with two-ply fasteners spaced at eight-inch on-center intervals. The specification includes a one-piece counterflashing, specified sealant application, and specified insulation materials. The roof deck assembly incorporates gravel surfacing installed into a reglet and secured with lead wedges at eight-inch on-center spacing, a flexible vapor retarder serving as an insulation retainer, compressible insulation, and wood nailers secured to the deck with appropriate fasteners in two staggered rows at twenty-four-inch on-center spacing. Additional components include stripping base flashing in twelve-inch on-center staggered rows, wood blocking in two rows, and wood cant nailed to the sheet, with a four-inch minimum measurement specification noted.

No pricing terms, contract award dates, response deadlines, or procurement-related information is contained within this technical drawing. The document serves solely as a construction specification guide and does not address procurement timeline, funding sources, set-asides, or other contractual elements relevant to a solicitation process.

View the file

Other files

File Type Posted
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 11

BUILT-UP ROOF

HOT/COLD WALL FLASHING FOR

NON-WALL-SUPPORTED DECK

SPECIFIED BUR MEMBRANE

TWO-PLY

FASTENERS 8'' O.C.

ONE PIECE COUNTERFLASHING

SPECIFIED SEALANT

SPECIFIED INSULATION

ROOF DECK AS SPECIFIED

GRAVEL SURFACING

INSTALLED INTO REGLET AND

SECURED w/ LEAD WEDGES 8'' O.C.

FLEXIBLE VAPOR RETARDER

TO SERVE AS INSULATION

RETAINER

COMPRESSIBLE INSULATION

WOOD NAILER SECURED TO

DECK w/ APPROPRIATE

FASTENERS, 2 ROWS

STAGGERED EACH ROW

24'' O.C.

STRIPPING

SPECIFIED BASE FLASHING

ROW 12'' O.C.

STAGGERED EACH

BLOCKING, 2 ROWS

NAIL WOOD CANT TO

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

4'' MIN.

Sheets and Views