Light-Metal-Parapet-Cap.pdf

PDF 138 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 2
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for a light-metal parapet cap roofing system. The drawing provides detailed construction specifications for the installation of a two-ply Tremco membrane roofing system with built-up roofing (BUR) and gravel surfacing. The specification includes a metal light-metal parapet cap assembly with fastening requirements, including continuous cleats fastened at 16-inch on-center spacing with a maximum span of 10 feet. The roofing membrane is installed over a Tremco nailer with 2-inch turn-down ends at a 45-degree angle, and the flashing details reference Factory Mutual Data Sheet I-49. The drawing is presented at not-to-scale (NTS) and dated 2023, showing a cross-sectional view (Section A-A) of the parapet cap assembly with specifications for base flashing, insulation, deck components, and sealant application between the wall and cap assembly.

The document does not contain information regarding pricing, set-asides, incumbent contractors, funding sources, response dates, or contract terms. This is a technical drawing intended to serve as construction guidance for roofing installation rather than a procurement opportunity document with commercial or financial terms.

View the file

Other files

File Type Posted
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 36

TWO-PLY TREMCO

AS SPECIFIED

ROOF DECK

INSULATION

SPECIFIED BUR

GRAVEL SURFACING

BASE FLASHING

ATTACH NAILER TO

NEOPRENE GASKETED

AS SPECIFIED

SEALANT BETWEEN

WALL REFER TO

FACTORY MUTUAL

DATA SHEET I-49

CONTINUOUS CLEAT

FASTENED 16'' O.C.

4'' MIN.

10'-0'' M

AX.

A

A

SECTION A-A

FASTENER 24'' O.C.

METAL SECTIONS

FLASHING MEMBRANE

INSTALLED OVER

TREMCO NAILER

2''

TURN ENDS DOWN

45 ANGLE

SPECIFIED CANT

STRIPPING

BUILT UP ROOFING

HOT/COLD LIGHT METAL PARAPET CAP

MEMBRANE

SHEET TITLE:

DRAWING No.:

SCALE:

NTS