Plumbing-Vent-Model.pdf

PDF 155 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 2
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical drawing specification document for plumbing vent flashing installation on built-up roofing systems. The document provides detailed standards for soft metal flashings used in hot and cold plumbing vent applications. Specifications include minimum material requirements of 4 lb sheet lead per square foot or 16 oz sheet copper, with provisions for asphalt-coated roofing felt when copper flashing is installed over iron or steel pipes to prevent galvanic corrosion. The drawing specifies installation requirements including a minimum 4-inch flange, 1-inch insertion depth into the plumbing vent stack, and placement of the flange in specified mastic sealant. For plumbing vents with diameters less than 2 inches, soft metal caps are required, also installed 1 inch down into the pipe using specified adhesive. The flashing must be set against two target plies of the specified BUR (built-up roofing) membrane with specified insulation and roof deck materials.

The document does not contain information regarding pricing terms, contract duration, renewal options, set-asides, incumbency status, funding sources, or other financial and administrative contract details. This drawing serves as a technical specification reference for construction or roofing contractors performing plumbing vent flashing work and would typically be incorporated as a specification exhibit within a larger construction contract or scope of work document.

View the file

Other files

File Type Posted
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Hot-Stack-Penetration.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Pre-Molded-Pipe-Flashing-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DWG NO. 08

NOTES

SOFT METAL FLASHINGS

1. SHEET LEAD: MINIMUM 4 LB. (20kg²/m ) PER SQ.FT.

2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED ROOFING FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR

METALS.

BUILT-UP ROOFING HOT/COLD

PLUMBING VENT FLASHING

ROLLED SOFT METAL FLASHING

1'' DOWN INTO PIPE

STEEL SCREEN

OPTIONAL SOLDER STAINLESS:

PLUMBING VENT STACK

PLUMBING VENT STACK

SET FLANGE IN

SPECIFIED MASTIC

MASTIC SEAL

TWO TARGET PLIES ADHERED

SPECIFIED BUR MEMBRANE

SPECIFED INSULATION

ROOF DECK AS SPECIFIED

FOR PLUMBING VENTS WITH

DIAMETERS LESS THAN

2'' USE SOFT METAL CAPS

SOFT METAL CAP 1'' DOWN

INTO PIPE

IN SPECIFIED ADHESIVE

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

AutoCAD SHX Text

4'' MIN. FLANGE

AutoCAD SHX Text

2'' MIN.