This is a technical drawing specification document for plumbing vent flashing installation on built-up roofing systems. The document provides detailed standards for soft metal flashings used in hot and cold plumbing vent applications. Specifications include minimum material requirements of 4 lb sheet lead per square foot or 16 oz sheet copper, with provisions for asphalt-coated roofing felt when copper flashing is installed over iron or steel pipes to prevent galvanic corrosion. The drawing specifies installation requirements including a minimum 4-inch flange, 1-inch insertion depth into the plumbing vent stack, and placement of the flange in specified mastic sealant. For plumbing vents with diameters less than 2 inches, soft metal caps are required, also installed 1 inch down into the pipe using specified adhesive. The flashing must be set against two target plies of the specified BUR (built-up roofing) membrane with specified insulation and roof deck materials.
The document does not contain information regarding pricing terms, contract duration, renewal options, set-asides, incumbency status, funding sources, or other financial and administrative contract details. This drawing serves as a technical specification reference for construction or roofing contractors performing plumbing vent flashing work and would typically be incorporated as a specification exhibit within a larger construction contract or scope of work document.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 08
NOTES
SOFT METAL FLASHINGS
1. SHEET LEAD: MINIMUM 4 LB. (20kg²/m ) PER SQ.FT.
2. SHEET COPPER: MINIMUM 16 OZ. IF COPPER FLASHING IS INSTALLED OVER AN IRON OR STEEL PIPE, WRAP AN ASPHALT COATED ROOFING FELT TO PREVENT DIRECT CONTACT BETWEEN TWO DISSIMILAR
METALS.
BUILT-UP ROOFING HOT/COLD
PLUMBING VENT FLASHING
ROLLED SOFT METAL FLASHING
1'' DOWN INTO PIPE
STEEL SCREEN
OPTIONAL SOLDER STAINLESS:
PLUMBING VENT STACK
PLUMBING VENT STACK
SET FLANGE IN
SPECIFIED MASTIC
MASTIC SEAL
TWO TARGET PLIES ADHERED
SPECIFIED BUR MEMBRANE
SPECIFED INSULATION
ROOF DECK AS SPECIFIED
FOR PLUMBING VENTS WITH
DIAMETERS LESS THAN
2'' USE SOFT METAL CAPS
SOFT METAL CAP 1'' DOWN
INTO PIPE
IN SPECIFIED ADHESIVE