Pre-Molded-Pipe-Flashing-Model.pdf

PDF 115 KB Posted

Attached to
High School Roof Replacement
Solicitation number
RFP MASO 260000002613 2
Issued by
Genesee County, Edmore Village, Michigan

About this file

This is a technical specification document for pre-molded pipe flashing, presenting a detailed engineering drawing that outlines the construction and assembly requirements for pipe penetration sealing systems. The document specifies the components and materials required for the flashing installation, including approved sealant, stainless steel worm gear clamps, pre-molded Tremply Kee flashing material, hot air weld Tremply Kee membrane, Tremply Plus fasteners with stress plates (minimum of four fasteners per installation), and insulation attached according to specification requirements. The drawing is designated as Drawing No. 78 and is presented at a "not to scale" (NTS) measurement, dated 2023, and serves as a visual reference for contractors and installers responsible for implementing pipe penetration solutions.

This document does not contain information regarding pricing terms, bid schedules, set-asides, contract award dates, funding sources, or procurement timelines. The file functions solely as a technical specification and engineering drawing reference for use during the procurement and construction phases of a project involving pipe flashing installation. No specific quantities, delivery dates, or contractual terms are identified in this specification document.

View the file

Other files

File Type Posted
Mason High School- AOC.pdf PDF
~WRL0001.tmp —
Mason High School Summer of 2027 Roofing Scope of Work.docx DOCX document
2-Piece-Shop-Fabricated-Metal-Edge-Flashing-Model.pdf PDF
Typical-Edge-Flashing-Model.pdf PDF
Curb-for-Air-Handling-Unit.pdf PDF
Plumbing-Vent-Model.pdf PDF
Hot-Stack-Penetration.pdf PDF
Gauge-or-Thickness-Guide.pdf PDF
Dail-Water-Stop-Tie-In-Model.pdf PDF
AFFIDAVIT OF COMPLIANCE IRAN.docx DOCX document
Mason Middle School- Alternate AOC.pdf PDF
Addendum #1.pdf PDF
Mason High School Summer of 2027 Roofing Bid Form.doc DOC document
Project-Mason High School THERMastic 80 Roofing Replacements.pdf PDF
Roof-Drain-with-Gravel-Guard.pdf PDF
Wood-Curb-Model.pdf PDF
Roof-Hatch-Model.pdf PDF
Conduit-or-Piping-Support.pdf PDF
Slip-Metal-Skirt-Flashing.pdf PDF
Light-Metal-Parapet-Cap.pdf PDF
Pitch-Pocket-with-Grout.pdf PDF
Typical-Covers-at-Membrane-T-Laps-Model.pdf PDF
TremPly-KEE-at-Fascia-System-Raised-Cant-Edge-Model.pdf PDF
Field-Fabricated-Pipe-Flashing-Model.pdf PDF
Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf PDF
Gutter-Flashing-Model.pdf PDF
TLRFIA-over-Steel-Model.pdf PDF
Piping-Through-Roof-Deck.pdf PDF
Notice To Bidders Mason High School Summer of 2027.docx DOCX document
Familial Relationship Disclosure.docx DOCX document
Composite-Roof-System-Cross-Section-Adhered-ISO-Hot-Model.pdf PDF
Door-Threshold-Model.pdf PDF
Equipment-Stand-Rain-Collar.pdf PDF
Flashing-for-Non-Wall-Supported (1).pdf PDF
Metal-Sleeve-and-Storm-Collar.pdf PDF
Metal-Flashing,-Round-to-Square.pdf PDF
Base-Sheet-Fastener-7-Inch.pdf PDF
Roof 13 to 15 Detail.pdf PDF
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPROVED SEALANT

STAINLESS STEEL

WORM GEAR CLAMP

TREMPLY KEE "PRE-MOLDED" FLASHING

HOT AIR WELD

TREMPLY KEE MEMBRANE

TREMPLY PLUS FASTENER

& STRESS PLATE

(MIN. 4 FASTENERS)

INSULATION ATTACHED PER

SPECIFICATION REQUIREMENTS

PIPE PENETRATION

SHEET TITLE:

DRAWING No.:

SCALE:

NTS

PRE-MOLDED PIPE FLASHING

DWG NO. 78

Sheets and Views
Model

File details come from the government source that posted it. Updated .