Roof-System-Attachment-Slope,-Transition,-Change-in-Plane.pdf
PDF 122 KB Posted
- Attached to
- High School Roof Replacement
- Solicitation number
- RFP MASO 260000002613 2
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical drawing specification document for roof system installation details. The drawing, designated as Drawing No. 85 and titled "Roof System Attachment at Slope Transition and Change in Plane," provides construction guidance for mechanically attaching roofing membrane systems at areas where roof planes transition or change slope. The specification requires that all roofing systems be mechanically attached at transitions in plane or slope greater than 1/4 inch per linear foot to prevent potential bridging of the membrane. The drawing depicts the use of Tremply Kee membrane products with fasteners and stress plates installed at 12-inch on-center spacing (typical) and hot air weld connections, with the membrane oriented in the machine direction for optimal performance.
This document serves as a technical reference for construction contractors and specifies the materials and installation methods required for compliant roof system attachment. The specification is presented at a not-to-scale (NTS) format and references Tremply Kee membrane and Tremply Plus fastener systems as the specified products. The document does not contain information regarding pricing, contract terms, bid schedules, award dates, or other commercial terms typically found in solicitation documents.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
ROOF SYSTEM ATTACHMENT AT SLOPE
TRANSITION AND CHANGE IN PLANE
DWG NO. 85
NOTES
TREMPLY KEE MEMBRANE
TREMPLY KEE MEMBRANE
MEMBRANE MACHINE DIRECTION
MEMBRANE MACHINE DIRECTION
TREMPLY PLUS FASTENER &
STRESS PLATE AT 12" O.C.
(TYPICAL)
HOT AIR WELD (TYPICAL)
1. ROOFING SYSTEMS SHALL BE MECHANICALLY ATTACHED AT ALL TRANSITIONS IN PLANE/SLOPE GREATER THAN 1/4" PER LINEAR FOOT TO ELIMINATE POTENTIAL BRIDGING OF THE MEMBRANE.
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .