Pitch-Pocket-with-Grout.pdf
PDF 145 KB Posted
- Attached to
- High School Roof Replacement
- Solicitation number
- RFP MASO 260000002613 2
- Issued by
- Genesee County, Edmore Village, Michigan
About this file
This is a technical drawing specification document for built-up roofing (BUR) construction detailing a pitch-pocket-with-grout assembly design. The drawing, designated as DWG No. 33, provides construction specifications for a hot/cold pitch pocket with grout used in roofing applications. The specification outlines the complete assembly process, including securing wood nailers to the roof deck using two staggered rows of fasteners spaced 24 inches on center, installing specified insulation, applying gravel surfacing with flange set in asphalt cement mechanically fastened at 3-inch intervals in a staggered pattern, and priming the metal flange before installing two-ply top-off with Tremco sealant. The metal pitch pocket must achieve a minimum 4-inch height and include specified drawband and sealant stripping.
The specification requires filling the pocket 1 inch from the top with non-shrink grout and installing a metal hood, with membrane placed under the primed metal flange and interior of the seal pipe base to prevent grout leakage into the building. The drawing is provided at NTS (Not To Scale) and appears to be part of 2023 construction documents. No pricing terms, funding sources, contract award dates, or procurement response deadlines are specified in this technical drawing. This document serves as a construction detail specification rather than a procurement solicitation and contains no information regarding set-asides, incumbent contractors, or contract renewal options.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DWG NO. 33
BUILT UP ROOFING
HOT/COLD PITCH POCKET WITH GROUT
WOOD NAILER SECURED
SPECIFIED BUR
SPECIFIED INSULATION
ROOF DECK
TO DECK w/ APPROPRIATE
FASTENERS, 2 ROWS
STAGGERED EACH
ROW 24'' O.C. AS SPECIFIED
GRAVEL SURFACING
FLANGE SET IN SPECIFIED
ASPHALT CEMENT, MECHANICALLY
FASTENED 3'' O.C., STAGGERED
PRIME METAL FLANGE BEFORE
STRIPPING
TWO-PLY
TOP OFF w/
TREMCO SEALANT
METAL PITCH POCKET
MINIMUM 4" HEIGHT
SPECIFIED DRAWBAND
AND SEALANT
STRIPPING
FILL 1'' FROM TOP
w/ NON-SHRINK GROUT w/ METAL HOOD
MEMBRANE UNDER
PRIME METAL FLANGE
PITCH POCKET AND
PRIME INTERIOR OF
SEAL PIPE BASE TO
PREVENT GROUT
LEAKAGE INTO BUILDING
SHEET TITLE:
DRAWING No.:
SCALE:
NTS
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .